My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEBER
>
701
>
2300 - Underground Storage Tank Program
>
PR0528938
>
REMOVAL_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 11:08:18 AM
Creation date
11/8/2018 9:59:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2008
RECORD_ID
PR0528938
PE
2361
FACILITY_ID
FA0019380
FACILITY_NAME
CITY OF STOCKTON
STREET_NUMBER
701
Direction
W
STREET_NAME
WEBER
City
STOCKTON
Zip
95202
CURRENT_STATUS
02
SITE_LOCATION
701 W WEBER
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEBER\701\PR0528938\REMOVAL 2008.PDF
QuestysFileName
REMOVAL 2008
QuestysRecordDate
8/16/2017 3:16:22 PM
QuestysRecordID
3583161
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
648
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br /> The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be representative <br /> of native soils beneath the tank's invert(tank's bottom)at a collection depth not to exceed 2-4 feet. If contamination is documented <br /> during closure,an Unauthorized Release Notification must be completed and submitted within five(5)working days pursuant to <br /> California Health&Safety Code,Section 25295. <br /> ' WATER NOT PRESENT IN THE TANK PIT <br /> ' TANK TANK SIZE MINIMUM NUMBER LOCATION OF SOIL SAMPLES <br /> ((J� #^^ (Gallons) of SOIL SAMPLES <br /> V — l < 1,000 1 per Tank Fill OR Pump End of Tank <br /> 1,000- 10,000 2 per Tank 1 at each End of Tank <br /> ' >10,000 3 or More Ends and Middle OR generally <br /> per Tank spaced along the length of the Tank A <br /> PIPING AND STOCKPILE <br /> =PIPING SAMPLES I Sample every 20 lineal feet <br /> ' r`v TANK&PIPING STOCKPILE SAMPLES 2 Samples every 50 cubic yards <br /> ' WATER IS PRESENT IN TANK PIT <br /> TANK TANK SIZE MINIMUM NUMBER LOCATION of SOIL MINIMUM NUMBER <br /> �n # (Gallons) of SOIL SAMPLES SAMPLES of WATER SAMPLES <br /> < 10,000 2 from w R=d to tank ends <br /> Single Tank 3 atsoiVgrouudwater interface I <br /> &I below tank <br /> > 10,000 OR 4 froffi,vY -veut-to tank eads <br /> Tank Cluster 5 or more at sod/grotmdwaterinterface 1 <br /> & 1 below each tank- . <br /> SLAB PRESENT IN THE TANK PIT <br /> Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order to <br /> ' collect the samples. (Physical removal of the abstraction will allow sampling according to the above conditions.) <br /> TANK TANK SIZE MINIMUM NUMBER LOCATION of SOIL SAMPLES <br /> �0 It (Gallons) of SOIL SAMPLES <br /> <1,000 3 per Tank Center and Ends OR Sides of Tank <br /> t1,000- 10,000 5 per Tank Center and Ends OR Sides of Tank <br /> > 10,000 5 OR More per Tank Ends and Middle and generally spaced <br /> along the length of the Tank <br /> EH 23 046 (Revised 07/31/08) 7 <br />