BILLING 1985 - 1992
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
2801
>
2300 - Underground Storage Tank Program
>
PR0231882
>
BILLING 1985 - 1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 1:55:21 PM
Creation date
11/8/2018 9:59:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985 - 1992
RECORD_ID
PR0231882
PE
2381
FACILITY_ID
FA0003555
FACILITY_NAME
AMERICAN MOULDING & MILLWORK
STREET_NUMBER
2801
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11709001
CURRENT_STATUS
02
SITE_LOCATION
2801 N WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\2801\PR0231882\BILLING 1985 - 1992 .PDF
QuestysFileName
BILLING 1985 - 1992
QuestysRecordDate
11/30/2016 12:40:54 AM
QuestysRecordID
3266721
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA,,, WATER RESOURCES CONTRr,.dOARD <br /> FORM B': UNDERGROUND STORAGE TANK PROGRAM `. <br /> TANK TANK PERMIT APPLICATION INFORMATION m <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. _ - Z <br /> IO <br /> MARK ONLY ❑ I NEW PERMIT ❑3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION A ❑ 7 P ANENTLY CLOSED TA <br /> ONE ITEM F-12 INTERIM PERMIT ❑�^T4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE TANK REMOVED /1�/ <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: RIO FARM TANK-YES❑ NC ❑ IV <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A <br /> A. OWNERS TANK ID# B. MANUFACTURED BY'. CTI <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A_ ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑OIL ❑ I PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF 461HAZARDOUS SUBSTANCE STORED&C A.S.# .S <br /> OA .#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,A D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑.r5IINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 6TEEUIRON ❑ 2 STAINLESS STEEL ❑3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑ 99 07HEfl <br /> C. INTERIOR ❑ I RUBBER LINED F] 2 ALKYD LINING F--] 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING Fj�6 UUNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLEWITH IOAMETHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE AW3 GRAVITY A U 91 NONE U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A CU 5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A(6)95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S I VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES E] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION N AGENCY N FACILITY ID S TANK ID N <br /> � CURRENT LOCAL AGENCY FACILITY IDN APPROVED BY NAME PHONE N WITH AREA CODE <br /> �1 PERMITN BER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> \ J CHECK N PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT N BY: C <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED o FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CU RENT FORMA' HAS BEEN FILED <br /> UVJ DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.