Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited. Chapter 6.7,Health and Safety Code;Chapter 16, Division 3, Title 13, California Code of Regulations <br /> This form most be used to document testing and servicing of monitoring equipment. A seoamte certification or report mast be orenared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner'operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> FacilityName: PG&E Bldg.No.: <br /> Site Address: 4040 West Ln City: Stockton Zip: 95204 <br /> Facility Contact Person: Michelle Le Contact Phone No.: (209) 602-7038 <br /> Make/Model of Monitoring System: TLS-350 Date of Testing/Servicing: 11/25/2008 <br /> B. Inventory of Equipment Tested/Certiffed <br /> Check the nate boxes to indicate s teifie meat 1 ected/servleed: <br /> Tank fill: Unleaded TanktD: Diesel <br /> N In-Tank Gauging Probe. Model: MOE2700 N lin-Tank Gauging Probe. Model. 578013-730 <br /> Z Annular Space or Vault Season. Model: 794390420 N Annular Space or Vault Sensor. Model: 794390420 <br /> Z Piping Sump'Trench Seasot(s). Model: 794380-208 Z Piping Sump i Trench Semot(s). Model: 794380.208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Seasons). Model: <br /> ❑Mechanical Lire teak Detector. Model: ❑Mechanical Litre Leak Detector. Model <br /> N Electronic fine Leak Detector. Model. 848480.001 Z Electronic fine Leak Defector Model: 848480-001 <br /> ❑Tank Overfill/High-Level Sersor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑thha(specify equipment type and model in Section E on Page 2). ❑Other( equipment specify eq p type and model in Section E on Page 2). <br /> Tank ID: Waste Oil Tank m: <br /> ❑In-Tank Gauging Probe. Model. ❑In-Tank Gauging Probe. Model: <br /> N Annular Space or Vault Sensor. Model: 794390420 ❑Anular Space or Vault Sensor. Madel: <br /> Z Piping Sump/Trench Stations). Model: 794380.208 ❑Pipung Sump;Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Seasot(s). Model: <br /> ❑Mechanical lane Leak Detector. Model: ❑Mechanical line Leak Detector. Model: <br /> N Electronic fine Irak Detector. Model: 848480-001 ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill i High-Level Sensor. Model: ❑Tank Overfill High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1/2 Diesel Dispenser ID: 1 Unleaded <br /> N Dispenser Containment Senscos), Model: 794380.208 N Itspenser Containment Sensor(s). Model: 794380-208 <br /> Z Shear Valve(s). N Shear Valve(s). <br /> Z Dispenser Containment Float(s)and Charts) Z Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: 2 Unleaded Dispenser 1D: <br /> N Dispenser Containment Sensor(s). Model: 794380.208 ❑Dispense Containment Sensor(s). Model: <br /> N Shear Valve(s). ❑Shear Valve(s). <br /> N Dispenser Containment Floats)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser tD: Dispenser ID: <br /> ❑Dispenser Containment Sensors). Model: ❑Dispeasa Contaimnent Sertums). Model: <br /> ❑Sheer Valve(s). ❑Sbrar Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s)_ ❑Dispenser Conuaimncnt Finials)and Chain(s). <br /> -if the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -1 certify that the equipment identified in this document was inspected/serviced In accordance with the manufacturers' <br /> guidelines. Attached to this Certification is Information (e.g. manufacturers' checklists) necessary to verify that this Information Is <br /> correct and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports,1 have also <br /> attached a copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): Christopher Thornton Signature: <br /> Certification No.: A31M License.No.: 220793 <br /> Testing Company Name: Gettler-Ryan ine. Phone No.:(925) 5513777 <br /> Testing Company Address: 6747 Sierra CL,Ste J, Dublin Ca Date of Testing/Servicing: 11/25/2008 <br /> Pap 1 of 3 <br /> Rev(Z(o8) <br />