Laserfiche WebLink
*J~ UNDERGROA STORAGE TANK MOAORING PLAN <br /> IN For use by Unidocs Member Agencies or where approved by your Local Jurisdiction <br /> Authority Cited: Title 23 CCR, Sections 2632(d)(1), 2634(d)(2), and 2641(h) <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION Mol. <br /> PLAN TYPE ❑ MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. Moe. <br /> (Check one item only) ® THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): l ) Unleaded R (1) Diesel <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agen Use Only) <br /> FACILITY NAME StoC On Service Center Moa. <br /> FACILITY SITE ADDRESS 40 West Lane M00 C Stockton M05. <br /> 11. QUIPMENT TESTING AND PREVENTIV MAINTENANCE <br /> State law requires that testing,prevent a maintenance,and calibration of monitoring equipment(e.g.,Yfisors,probes,line leak detectors,etc.)be performed in M06. <br /> accordance with the equipment manufactrs'instructions,or annually,whichever is more frequent. uch work must be performed by qualified personnel. <br /> MONITORING EQUIPMENT IS SERVIC ® 1.ANNUALLY ❑ 99.OTHER(Specify): MOT <br /> III. MONITORING LQCATIONS <br /> This monitoring plan must include a Site Plan sI Ing the general tank and piping layouts d the locations where monitoring is performed(i.e.,location of each sensor, <br /> line leak detector,monitoring system control panel, tc.). If you already have a diagram .g.,current UST Monitoring Site Plan from a Monitoring System Certification <br /> form,Hazardous Materials Business Plan map,etc.)ftich shows all required informatiplin,include it with this plan. <br /> IV. TANK NITORING <br /> MONITORING IS PERFORMED USING THE FOLLO G METHOD(S):(C ck all that apply) MM <br /> ® L CONTINUOUS ELECTRONIC MONITORING OFNK ANNULA INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) <br /> SECONDARY CONTAINMENT IS: ® a.DR ❑ b. QUID FILLED ❑ c.UNDER PRESSURE ❑ it.UNDER VACUUM Mr, <br /> PANEL MANUFACTURER: VeederROOt M12, MODEL#: 350 M13, <br /> LEAK SENSOR MANUFACTURER: VeederRoot M1° MODEL#(S): 794390-420 Mls. <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USEDT ONITOR SINGLE WALL TANKS) <br /> PANEL MANUFACTURER: M16. MODEL#: MIT <br /> IN-TANK PROBE MANUFACTURER: MIS MODEL#(S): M19, <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUO S ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY M20. <br /> ❑ d.MONTHL ❑ e.OTHER(Specify): M21. <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h ❑ b.0.2 g. .h. ❑ c.OTHER(Specify): Mzz. Mz3, <br /> ❑ 3.INVENTORY RECONCILIATION ❑ a.MANU L PER 23 CCR§2646 ❑ b.STATISTICAL PER 23 CCR§2646.1 Mx°. <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG) ER 23 CCR§2645 <br /> TESTING PERIOD: ❑ a.36 OURS ❑ b.60 HOURS M25. <br /> ❑ 5.INTEGRITY TESTING PER 23 CCR§2643. <br /> TEST FREQUENCY: ❑ a. NNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): Mee. Mn. <br /> ❑ 6.VISUAL MONITORING DONE: ❑ DAILY ❑ b.WEEKLY(Requires eneyapprovap <br /> ❑ 99.OTHER(Specify): M28. <br /> V. PIPE MONITORING <br /> MONITORING IS PERFORMED USING E FOLLOWING METHOD(S)(Check all that apply) Mao. <br /> ® 1.CONTINUOUS ELECTRONIC M NITORING OF PIPING SUMP(S)/TRENCH(ES)AND OT R SECONDARY CONTAINMENT <br /> SECONDARY CONTAMM NT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c. DER PRESSURE ❑ d.UNDER VACUUM M31. <br /> PANEL MANUFACTURE :VeederROot M3z. MODEL#: 350 M33. <br /> LEAK SENSOR MANUF CTURER: VeederROOt M3°, \TESTS <br /> : 794380-208 Mas. <br /> WILL A PIPING LEAK ALARM TRIGGER AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOW ® a.YES ❑ b.NO M36. <br /> WILL FAILURE/DIS NNECTION OF THE MONITORING SYSTEM TRIGGER AUTOMATITDOWN? ® a.YES ❑ b.NO M31 <br /> ❑ 2.MECHANICAL LINE AK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g.p.hTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WH A LEAK IS DETECTED <br /> MLLD MANUFA TURER(s):VeederROot _ M3s. M39. <br /> 3.ELECTRONIC LIN LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK <br /> ELLD MANUFACTURER:VeederRDOt M4°, MODEL#: M41 <br /> PROGRAMMED LINE INTEGRITY TESTS: ❑ a.MINIMUM MONTHLY 0.2 h. ❑ b.MINIM M ANNUAL0.1 g.p.h. M42- <br /> gp <br /> WILL ELLD DETECTION OF A PIPING LEAK TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a.YES ❑ b.NO M43. <br /> WILL ELLD FAILUREIDISCONNECTION TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a.YES ❑ b.NO M44 <br /> ❑ 4.INTEGRITY TESTING <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) M45. M46. <br /> ❑ 5.VISUAL MONITORING DONE: ❑ a.DAILY ❑ b.WEEKLY' ❑ C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED" M47. <br /> •Requires agency approval '•Allowed for monitoring of unburied emergency generator fuel piping only per HSC§252815(b)(3) <br /> ❑ 6.PIPING IS SUCTION PIPING MEETING ALL REQUIREMENTS FOR EXEMPTION FROM MONITORING PER 23 CCR§2636(a)(3) <br /> ❑ 7.NO PRODUCT OR REMOTE FILL PIPING IS CONNECTED TO THE USTS) <br /> ❑ 99.OTHER(Specify) M48. <br /> UN-022A-1/5 www.unidocs.org Rev.10/14/03 <br />