My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:59:06 PM
Creation date
11/8/2018 9:59:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
8/2/2018 4:41:39 PM
QuestysRecordID
3952362
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i 0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility PG&E: Stockton Service Center Facility 4040 West Ln Stockton, CA Inspection Se 18, 2014 <br /> Name: Address: Date: p <br /> VIOLATIONS <br /> # C1 I C2 I M I Code Section HSC=CA Health and Safety Code,CFR=Code of Federal Regulations <br /> C1=Class 1 violation,C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (Mi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (Mt) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> On site to conduct the Routine Inspection and witness the Monitoring System Certification. <br /> Minor violations: (310, 313): <br /> 310. Liquid was observed in the Diesel STP Sump on the north side (approximately 1 cup) and the <br /> south side of the sump (approximately 1 1/2 cups). If water could enter into the secondary containment <br /> by precipitation or infiltration, it must be removed and disposed of properly. Immediately remove this <br /> liquid, make a hazardous waste determination per Title 22 hazardous waste regulations, and manage it <br /> accordingly. Ensure that the Diesel STP sump is maintained free of liquid. The technician removed the <br /> liquid in the Diesel STP Sump and placed in a hazardous waste drum. The violation was corrected on <br /> site. <br /> 313. The Diesel direct-bury spill container failed when tested. All spill containers shall have a minimum <br /> capacity of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. <br /> Immediately discontinue deposition of petroleum into this tank until the component is repaired or <br /> replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EHD. <br /> If the spill container can't be replaced immediately, there is a possibility that the UST system may be <br /> red tagged to prevent fuel inputs. The technician replaced the cap and the test passed. The violation <br /> was corrected on site. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> I <br /> Received By, Title <br /> nspector : <br /> EHD 2 6 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.