My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:59:06 PM
Creation date
11/8/2018 9:59:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
8/2/2018 4:41:39 PM
QuestysRecordID
3952362
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9255517888 Line 1 11:38:29 09-24-2013 3112 <br /> GETTCER-RYAN INC. • • R,G 1Job# 20-59217,8 <br /> 1 <br /> D. Results of TestinglServicing E(;E i V ®17U <br /> Software Version Installed, 120.02 SEP 24 2013 <br /> Complete the following checklist: <br /> [Z yes D NO' Is theaudiblealarmoperalional? _ <br /> [Z Yes [I No' Is the visual alerts operational? <br /> E Yes D No' Were all sensors visually Inspected functionally tested,and confirmed operational? <br /> [Z Yes No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> prapere ratbn7 <br /> Yes p No' /alarms are relayed to a remote monitoring slogan,is all communication equipment(e.g.modem)operational? <br /> N/A <br /> ry Yes No' For pressurized piping systems,does the turbine alltomatWy shut down if the piping secondary containment monitoring system <br /> 0 NIA detects a teak,falls to operate,or is electrically disconnected?If yes:which sensors Initiate positive shut-down?(Check all that apply) <br /> 11 Sump/trench Sensor, E Dispenser Containment Sensor.Did you confirm positive shut-down due to leaks Mit sensor <br /> failure/disconnection? E Yes; L] No. <br /> 0 Yes 0 No' For tank systema mat utilize me monitoring system as the primary tank overfill warning device(.e.rw mechanical overfill prevention <br /> N/A valve is installed),is the overfill waming alarm visible and audible at the tank fill point(s)and operating properly?If so,at whet percent <br /> of tank capacity does the alarm trigger? <br /> Yes (y No Was any monitoring equipment replaced?If yes,Identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement parcs in Section E,below. <br /> Yes No Was liquid found Inside any secondary containment systems tlesigned as dry system?(Check all that appy) Qprotlucl; Water. If <br /> yes,describe causes in Section E,below. <br /> F Yes 0 No' Was monitoring system set-up reviewed to insure proper settings?Attach set-up reports,If applicable. <br /> Yes No' Is aA monitoring equipment operational per manufacture's specifications? <br /> In Section E below,dosed be how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> All Ok <br /> Site is equiped with hydraulic oil tank that has an L12& 113 (pin 794390420)sensors <br /> Monitoring System Certification Page 2 of 4 12107 <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.