My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:56:03 PM
Creation date
11/8/2018 9:59:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
7/23/2018 8:37:33 PM
QuestysRecordID
3946151
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> D. Results of Testing/Servicing JUN 14 2017 <br /> Software Version Installed: 120.02 ENVIRONMENTAL HEALTH <br /> Complete the following checklist: DEPARTMENT <br /> ❑X Yes ❑No* Is the audible alarm operational? <br /> ❑X Yes ❑No* Is the visual alarm operational? <br /> Q Yes ❑No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> ❑X Yes ❑No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their <br /> proper operation? <br /> ❑ Yes ❑No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem) <br /> ❑X N/A operational? <br /> ❑ Yes ❑No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary <br /> ❑X N/A containment monitoring system detects a leak,fails to operate,or is electrically disconnected?Ifyes:which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> ❑Sump/Trench Sensors; ❑DispenserContainmentSensors. Did you confirm positive shut-down <br /> due to leaks and sensor failure/disconnection? <br /> ❑Yes; ❑No. <br /> ❑ Yes ❑No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> mechanical overfill prevention valve is installed),is the ovetfill warning alarm visible and audible at the <br /> 0 N/A tank fill point(s)and operating properly?If so, at what percent of tank capacity does the alarm trigger? <br /> =Yes- 0 No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑Yes* ❑X No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that <br /> apply) ❑Product; ❑Water.If yes,describe causes in Section E,below. <br /> ❑X Yes ❑No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ❑X Yes ❑No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were orwill be corrected. <br /> E. Comments: <br /> Other sensors from page one: <br /> L16: Waste Oil drain pan sensor :794380-208 Certified <br />
The URL can be used to link to this page
Your browser does not support the video tag.