My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:56:03 PM
Creation date
11/8/2018 9:59:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
7/23/2018 8:37:33 PM
QuestysRecordID
3946151
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ji <br /> y i A <br /> SEF 2 8 WRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> !—"tom <br /> This form is intended for use by contractors performing annual testing of'UST spill c4atlinment structures. The compleied form and <br /> printouts from tests(f applicable),should be provided to the facility owner/operator for submittal to the local regulatory agency. <br /> 1. FACILITY INFORMATION Facility ID: PGE095 <br /> Facility Name: Pacific Gas and Electric Company I Date of Testing: 9-13-2017 <br /> Facility Address: 4040 West Ln. Stockton CA 95204 <br /> Facility Contact: Alex Steele Phone: 209-736-6426 <br /> Date Local Agency Was Notified of Testing: 9/6/17 <br /> Name of Local Agency Inspector(f present during testing): Cesar Ruvalcaba <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name: TAIT Environmental Services <br /> Technician Conducting Test: Garrett Warren <br /> Credentials': ❑x CSLB Contractor ❑x ICC Service Tech. ❑SWRCB Tank Tester ❑Other(Specify) <br /> License Number(s): A B ASB C-10 HAZ,588098 8185019 <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: ❑x Hydrostatic []Vacuum ❑Other <br /> Test Equipment Used: Incon TS-STS Equipment Resolution: .0006 <br /> Identify Spill Bucket(By Tank I Unleaded 2 Diesel 3 Waste Oil 4 <br /> Number, Stored Product, etc.) <br /> ❑x Direct Bury ❑x Direct Bury ❑x Direct Bury ❑Direct Bury <br /> Bucket Installation Type: ❑Contained in Sump ❑Contained in Sump []Contained in Sump ❑Contained in Sump <br /> [I On Top of AST ❑On Top of AST ❑On To of AST []On Top of AST <br /> Bucket Diameter: <br /> Bucket Depth: 14" 14" 13.50" <br /> Wait time between applying 15 min 15 min 15 min <br /> vacuum/water and start of test: <br /> Test Start Time(TI): 9:18am/9:34am 9:18am/9:34am 12:07pm/12:23pm <br /> Initial Reading(Rj): 6.4612/6.4611 5.4976/5.4976 6.7841 /6.7840 <br /> Test End Time(TF): 9:33am/9:49am 9:33am/9:49am 12:22pm/12:38pm <br /> Final Reading(RF): 6.4611 /6.4608 5.4976/5.4972 6.7840/6.7839 <br /> Test Duration(TF—TI): 15 min/15 min 15 min/15 min 15 min/15 min <br /> F <br /> hange in Reading(RF-RI): .0001 /.0003 0/.0004 .0001 /.0001 <br /> ass/Fail Threshold or .002 .002 .002 <br /> riteria: <br /> Test Result: ❑x Pass ❑Fail I ❑x Pass ❑Fail ❑x Pass ❑Fail ❑ Pass []Fail <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Test water was left on site. <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. <br /> Technician's Signature: 66VX&ZUavi" Date: 9-13-2017 <br /> State laws and regulations do not currently require testing to be performed by a qualified contractor.However,local requirements <br /> may be more stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.