COMPLIANCE INFO 2001-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2001-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2024 10:58:05 AM
Creation date
11/8/2018 10:00:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2004
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2001-2004.PDF
QuestysFileName
COMPLIANCE INFO 2001-2004
QuestysRecordDate
5/24/2018 4:08:19 PM
QuestysRecordID
3903911
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MINIMUM VERIFICATION LABORATORY ANALYSIS <br /> OXYGEN <br /> TANK TANK TPH-G TPH-D BTX&E CL HC TOTAL MTBE ATES METAL PCB <br /> # CONTENTS 8015 8015 8020 8010 LEAD 8020 (MTBE, ICRP/ 8270 <br /> 8260 8260 8260 8240 7420 8260 TBA,DIPE, AES or 8080 <br /> ETBE, <br /> 8260 7421 TAME) AA <br /> 8260 <br /> LEADED GAS X X X X <br /> UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X X <br /> UNK FUEL X X X X X <br /> PROD.OIL X X X <br /> CHLOR. X <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTS X X <br /> WASTE\ <br /> USED OIL X X X X X X <br /> X <br /> mmimmmmmemil <br /> All analysis methods are the designated EPA methods described in EPA SW 846,Third Edition. Those methods not found in SW 846 are <br /> specifically noted below. Refer to the "SWRCB LUFT Field Manual",Appendix D (B), Table 3-5 on page A20 for minimum detection <br /> limits for motor vehicle fuel (gasoline and diesel). Refer to "Tri-Regional Board Staff Recommendations for Initial Evaluation and <br /> Investigation of UST's" for the waste and motor oil minimum detection limits. Detection Limits that remain below the MCL,STLC or <br /> Allowable Limit of the contaminant in question will be accepted,however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon,Gasoline,GC/FID(5030)8015 mod or GC/MS 8260 <br /> TPH-D Total Petroleum Hydrocarbon,Diesel,GC/FID(3550),8015 mod or GC/MS 8260 <br /> BTX&EBenzene,Toluene,Xylene&Ethyl Benzene,GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC/HSD 8010,GUMS 8240 or 8260 <br /> TOTAL LEAD Total lead,AA 7420, AA 7421 or ICP-AES 6010 <br /> OXYGENATES MTBE,ETBE,TAME,DIPE,&TBA GC/MS 8260(For MTBE screen only you may use 8020) <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000. Metals: <br /> Cadmium,Chromium III and VI,Lead,Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls,GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and nap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-free solvents are to be used. Fused capillary columns are preferred to packed columns;a <br /> packed column maybe used as a"first cut"with"dirty'samples or once the hydrocarbons have been characterized and proper QA/QC is followed. For <br /> drinking water sources,EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the detection <br /> limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination may require further analysis.PHS-EHD <br /> recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 05/09/00) <br /> 5 <br />