My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2001-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2024 10:58:05 AM
Creation date
11/8/2018 10:00:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2004
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2001-2004.PDF
QuestysFileName
COMPLIANCE INFO 2001-2004
QuestysRecordDate
5/24/2018 4:08:19 PM
QuestysRecordID
3903911
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � <br /> D. Results of Testing/Servicing <br /> Software Version Installed: <br /> Com lete the following checklist: <br /> Yes ❑ No* Is the audible alarm One <br /> Yes Cl No* 1s the visual alarm o erational? <br /> Yes ❑ No* Were all sensors visuall ins erred,functionall tested,and confirmed operational? <br /> Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper o eration? <br /> ❑ Yes ❑ No* If alarms are -relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> JW N/A operational? <br /> Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply)$Sump/Treneh Sensors;0 Dispenser Containment Sensors. <br /> Did You confirm positive shut-down due to leaks and sensor failure/disconnection?X Yes; ❑No. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> A N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fillpoint(s)and operating ro erl ? If so,at what percent of tank capacity does the alarm trigger? % <br /> Yes* ❑ No Was any monitoring equipment replaced? If yes,identify specific sensors, probes,or other equipment replaced <br /> and list the manufacturer name and model for all re lacement parts in Section E, below. <br /> ❑ Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)❑ <br /> Product; ❑Water. If yes, describe causes in Section E,below. <br /> Yes 1 ❑ No* Was monitorings stem set-u2 reviewed to ensure pro2er settings?Attach set up reports,if applicable <br /> Jff—Ys ❑ No* Is all monitoring a ui ment o erational er manufacturer's s ecifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. - <br /> E. Comments: `(ICP aq 1c,ebine men Yz -CCn �LflSd2 n4--�im-hontrig <br /> Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.