My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2001-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2024 10:58:05 AM
Creation date
11/8/2018 10:00:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2004
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2001-2004.PDF
QuestysFileName
COMPLIANCE INFO 2001-2004
QuestysRecordDate
5/24/2018 4:08:19 PM
QuestysRecordID
3903911
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Leak Detector Test Data Sheet <br /> "ARCO Products Company <br /> Station # Date 4—7 �q 19 <br /> Address <br /> Test Information <br /> 1 2 3 4 5 <br /> Product 1-7 <br /> Manufacturer L1/1 I ^� -!j <br /> Model <br /> Full Operating Pressure (psi) <br /> Line Bleed Back (ml) <br /> Trip Time (sec) <br /> { <br /> Metering Pressure (psi) q� <br /> F/E Holding Pressure (psi) <br /> l L <br /> Test Leak Rate (mllmin) (gph) �r 1 ��3 G1-\ <br /> r <br /> PASS or FAIL S S ^ 1 S S <br /> Replaced All Failed Leak Detectors Yes No N/A <br /> If No, Replacement To Be Completed By (Date) <br /> This letter certifies that the annual leak detector tests were performed at the above referenced facility <br /> according to the equipment manufacturers procedures and limitations and the results as listed are to my <br /> knowledge true and correct. The mechanical leak detector test pass/fail is determined using a low flow <br /> threshold trip rate of 3 gph at 10 PSI. 704 <br /> / <br /> Inspected By: Contractor <br /> Technician r"/ Lic# <br /> Signature <br /> APC-=5(fl96) <br />
The URL can be used to link to this page
Your browser does not support the video tag.