COMPLIANCE INFO 1986-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1756
>
2300 - Underground Storage Tank Program
>
PR0231300
>
COMPLIANCE INFO 1986-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2019 11:51:24 AM
Creation date
11/8/2018 10:00:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2004
RECORD_ID
PR0231300
PE
2361
FACILITY_ID
FA0001858
FACILITY_NAME
MY MINI MART
STREET_NUMBER
1756
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11721005
CURRENT_STATUS
01
SITE_LOCATION
1756 N WILSON WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1756\PR0231300\COMPLIANCE INFO 1986-2004.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
237
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed: <br /> Com lete the following checklist: <br /> Yes ❑ No* Is the audible alarm operational? <br /> es ❑ No* Is the visual alarm operational? <br /> ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> a-jr/A— operational? <br /> Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> P ositive shut-down? (Check all that apply) Gl'S p/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 3rT s;_T7 No. <br /> ❑ Yes L3 No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> /A mechanical overfill prevention,valve is installed), is the overfill warning alarm visible and audible at the tank <br /> q <br /> l point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? % <br /> ❑ Yes* as any monitoring equipment replaced? If yes,identify specific sensors,probes, or other equipment replaced <br /> d list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* as liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> Product; ❑Water. If yes, describe causes.in Section E,below. <br /> as monitoring system set-up reviewed to ensure proper settings?Attach setup reports,if applicable <br /> Yes all monitoring equipment operational per manufacturer's specifications? <br /> .*In Section E below,describe now and when these deficiencies were or will be corrected. <br /> ,E. Comments: <br /> Page 2 of 3 03101 - <br />