My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL INSTALLATION 2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
678
>
2300 - Underground Storage Tank Program
>
PR0516874
>
INSTALL INSTALLATION 2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:23 PM
Creation date
11/8/2018 10:01:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
INSTALLATION 2001
RECORD_ID
PR0516874
PE
2361
FACILITY_ID
FA0002463
FACILITY_NAME
PAQ Inc. DBA Food-4-Less
STREET_NUMBER
678
Direction
N
STREET_NAME
WILSON
STREET_TYPE
Way
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
678 N Wilson Way
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\678\PR0516874\INSTALLATION 2001.PDF
QuestysFileName
INSTALLATION 2001
QuestysRecordDate
3/21/2018 5:08:04 PM
QuestysRecordID
3832327
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19• <br />20. <br />21. <br />22. <br />23. <br />24. <br />25. <br />_ Piping (cross-sectional tram, including connections to tank and di3�Ensers). <br />(A) Vent and tank riser primary containment system equipped with overfill prevention system that: <br />V Restricts delivery of flow to tank [Section 2635 (b).(2) (B) or (C)], or <br />Provide positive shut off of flow to the tank at no more than 95 % [Section 2635 (b)(2)(01, or <br />(B) ✓ Vapor recovery piping designed so it cannot contain liquid phase product, or <br />(C) Suction piping (below grade piping operates at less than atmospheric pressure) [Section 2636 (a) (3)] <br />Sloped so contents of the pipe will drain back into the storage tank if the suction is <br />released. <br />No valves or pumps installed below grade. <br />V inspection method provided to demonstrate compliance with section 2636 (a) (3). <br />(D) ✓ Corrodible underground piping protected against corrosion (section 2636 (b)). <br />(E) Underground primary piping will meet all of the following requirements <br />_ Primary piping in contact with hazardous substance under normal operation conditions shalt be: <br />installed inside a secondary containment system in the form of: secondary pipe_Vault or <br />_lined trench to be sloped to a collection sump at the low point of the piping. <br />_✓ Primary piping and secondary containment systems will be installed in accordance with industry <br />code of practice and voluntary consensus standards.. <br />_✓ Lined trench used as secondary containment <br />_✓ Material compatible with the substance stored. <br />V' Covered and capable of supporting any expected vehicular traffic. <br />(F) Underground piping with secondary containment will be equipped and monitored as follows: <br />f Secondary containment will be equipped with a continuous monitoring system connected to an audible <br />and visual aLarm system. <br />Automatic line leak detectors wilt be installed on pressurized piping <br />Manufacturer: tl"'"/Qe�_ Model: TG5 - 3S0 <br />Annual monitoring will be conducted on the pressurized piping with secondary containment. <br />_ Annual line tightness test wilt not be required if the continuous monitor shuts down the pump and <br />activates the alarm system when a release is detected and when the continuous monitoring system <br />fails or is disconnected. <br />State Water Resources Control Board "Facility (A)" and "Tank Permit (B)" application forms submitted. <br />✓ Plan review and operating permit fees paid. `•L..' �,, ,.d <br />_ What is the approximate depth to ground water: %�9A �^e4 <br />(include source of information - borehole logs, monitoring well data, water <br />studies, etc.) <br />Total number of tanks on site after installation: t <br />✓ County/City Fire District and Building Department notified. <br />in the event contamination is observed, confirmed or suspected as a result of a leaking UST system it is your <br />responsibility [in accordance with (CCR) Title 23, Division 3, Chapter 16, Article 11, Corrective Action <br />Requirements] as an owner or operator to submit a workplan to PHS-EHD Site Mitigation Unit prior to initiating any <br />assessment or remediation activities. For further assistance contact the Site Mitigation Unit at (209) 469-3450. <br />The owner or operator must acknowledge this responsibility for workplan submittal by signature and date below. <br />Name Title Date <br />T n A- 1 .. n n <br />CONDITIONS OF APPROVAL: <br />7 S � c�ti-¢ems <br />., / �. i:' <br />U <br />
The URL can be used to link to this page
Your browser does not support the video tag.