INSTALL INSTALLATION 2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
678
>
2300 - Underground Storage Tank Program
>
PR0516874
>
INSTALL INSTALLATION 2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:23 PM
Creation date
11/8/2018 10:01:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
INSTALLATION 2001
RECORD_ID
PR0516874
PE
2361
FACILITY_ID
FA0002463
FACILITY_NAME
PAQ Inc. DBA Food-4-Less
STREET_NUMBER
678
Direction
N
STREET_NAME
WILSON
STREET_TYPE
Way
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
678 N Wilson Way
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\678\PR0516874\INSTALLATION 2001.PDF
QuestysFileName
INSTALLATION 2001
QuestysRecordDate
3/21/2018 5:08:04 PM
QuestysRecordID
3832327
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPW 233 SE <br />EXTRACTOR FITTINGS <br />OPW 233 Series Extractor Fittings thread into 4" NPT openings on underground dstorage <br />tanks. A 4" riser pipe threads into the top of the 233 for use in Stage I Vapor Recovery <br />or to access a ball Float. The 233 Extractor Fittings have threaded single -outlet <br />connections for attaching tank vent lines or multiple outlets used to manifold tank <br />vents or accommodate Stage II vapor return lines from dispensers. Internal threads <br />on the 233 are designed to install a ball Float or test plug in the extractor. <br />Features Include <br />• Duragard® Coated Cast Iron Body — <br />Helps prevent rust and corrosion for <br />long service life. <br />• ZA12 Zinc/Alloy Cage Assembly — <br />Eases installation and removal of ball <br />float vent valves and test plugs. <br />OPW 233 <br />• Precision Machined Threads — Help <br />prevent cross threading of the ball Float <br />or tank riser pipe. <br />The OPW 233 Extractor Fittings are designed for use with all OPW 30MV and 3" 53VML <br />Ball Float Vent Valves that include an extractor cage (the OPW 233 does not include an <br />extractor cage). The 233 Extractor incorporates either single -outlet or multiple outlet threads. <br />OPW 233V <br />The OPW 233V Extractor Fittings are designed for use with all OPW 53V 2" Ball Float <br />Vent Valves (the OPW 233V includes an extractor cage). The 233V is a threaded <br />single -outlet extractor designed to connect vent lines to the underground tank. <br />OPW 233VM <br />The DPW 233VM Extractor Fittings are designed for use with all OPW 53V 2" Ball Float <br />Vent Valves. (The OPW 233VM includes an extractor cage). The 233VM is a multiple - <br />outlet extractor used to manifold tank vents or accommodate Stage II vapor return lines <br />from dispensers. <br />OPW 233VP Extractor Test Plug <br />The OPW 233VP Extractor Fitting Test Plug is used on all OPW 233, 233V and 233VM <br />Series Extractor Fittings. The 233VP incorporates an 0 -ring above the threads (on the <br />Plug) to isolate the tank from the vent piping systems during a tank test. <br />OPW 233VMP Extractor Test PI <br />The OPW 233VMP Extractor Fitting Test Plug is used with the OPW 1611VR Slide Sleeve <br />Vapor Recovery Adaptor System. The 233VMP incorporates an 0 -ring below the threads <br />(on the plug) to isolate the tank from the vent piping systems during a tank test. <br />Ordering Specifications <br />Product No. <br />Top Thread <br />in. mm. <br />Outlet Thread <br />in. mm. <br />Bottom Thread <br />in. mm. <br />Weight <br />lbs kgs <br />233-4420 (Tee)' <br />4" <br />102 <br />2" <br />51 <br />4" <br />102 Ext. <br />13A <br />6.31 <br />233.4430 (Tee)` <br />4" <br />102 <br />3" <br />76 <br />4" <br />102 ExL <br />14.06 <br />6.39 <br />233.4422 (Cross)' <br />4" <br />102 <br />2" x 2" <br />51 x 51 <br />4" <br />102 Ext. <br />1518 <br />6.90 <br />233.4433 (Cross)' <br />4" <br />102 <br />3" x 3" <br />76 x 76 <br />4" <br />102 Ext. <br />15-54-7.06 <br />233.4432 (Cross)' <br />4" <br />102 <br />3" x 2" <br />76 x 51 <br />4" <br />102 Ext. <br />17.29 <br />7.86 <br />233V-4420 (Tee) <br />233V-4430 (Tee) <br />233VM-4422 (Cross) <br />--- <br />233VM-4433 (Cross) — <br />4" <br />- 4" <br />4" <br />4" <br />102 <br />102 <br />102 <br />102 <br />2" <br />3" <br />2" x 2" <br />3" x 3" <br />51 <br />76 <br />51 x 51 <br />76 x 76 <br />4" <br />4' <br />4" <br />4" <br />_102EA <br />102 Ext. <br />102 Ext. <br />102 Ext. <br />15.33 <br />12.50 <br />16.62 <br />--- <br />16.98 <br />6.99 <br />5.68 <br />7.55 <br />7.72 <br />233VM-6045 (Cross) <br />233VM-604L (BSPP) <br />4" <br />4" <br />102 <br />102 <br />3" z 2" <br />3" x 2" <br />76 x 51 <br />76 x 51 <br />4 <br />4" <br />102 EA. <br />102 EzL <br />16.61 <br />16.62 <br />8.51 <br />8.51 <br />' without cage assembly <br />(TEE) <br />(CROSS) <br />Replacement Parts <br />DPW 233V and 233VM <br />Part No. Description <br />H-8932 Cage SA <br />
The URL can be used to link to this page
Your browser does not support the video tag.