My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO 1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2023 10:49:21 AM
Creation date
11/8/2018 10:02:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\1434\PR0231465\COMPLIANCE INFO 1998-2003.PDF
QuestysFileName
COMPLIANCE INFO 1998-2003
QuestysRecordDate
6/26/2017 11:25:13 PM
QuestysRecordID
3467494
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATE 2s o3 <br /> SAN JOAQUIN COUNTY PR# <br /> ENVIRONMENTAL HEALTH DEPARTANT PAGE <br /> 304 E.Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION <br /> REPORT <br /> Facility Name TAG(�QD�- roarO MAf' - Facility Address l y3`-f W- T OS2M ik 4W - <br /> FaciltyContactVc �'-- Cing140VQTitle 0lr4RA— Phone # 73-2 � ?92 <br /> UST#q Product Qom_ UST# S Product 005 UST#& Product 11 'C" • UST#_Product <br /> Overfill Prevention: ❑AudibleNisual )$,'Mechanical Monitoring Panel: 2 T(-S MSO <br /> Piping System: O Gravity XPressure O Suction Violations: inor O Major o ^w <br /> Automatic Pump Shut Down Satisfies CCR 2636 Yes U No Dispenser Pan: XYes O No 6"kv1L^,- <br /> INSPECTION TYPE: p Routine Monitoring Certification OComplaint /O�ln�sttall�❑Removal ❑Repair/Upgrade <br /> COMPANY NAME: I-ANK TPV, TECHNICIAN NAME: z°4 V cw�� �� PHONE: <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance & monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> month/36 month) 21 CCR 2636 (f)(4) Annual line tightness test <br /> 3 CCR 2711(b)& (c) Current State Forms A& B 22 CCR 2630 (d) Annual line leak detector test <br /> 4 V HSC 25292.2 Certification of financial 23 CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring &20 containment <br /> 7 HSC 25291 (e) Water in secondary(20)cont 26 CCR 2643 (e) Biennial tightness test of gravity <br /> 8 HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously <br /> 9 CCR 2636 (f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12 CCR 2636(f)(1) Continuous monitoring system 30 HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13 CCR 2635 (b)(1) Spill container 31 HSC 25298 (b) Permit to temporarily close US- <br /> 14 CCR <br /> S"14CCR 2635 (b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed and <br /> 16 HSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1 000'of Public Well, no ELD <br /> unauthorized release 35 CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 CCR 2632 (d) Monitoring & response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19 CCR 2712 (i) Monitoring &response plan is 37 Violation(s) not listed above <br /> on site <br /> EHD INSPECTOR: 197J PHONE: <br /> Y6 i— <br /> RECEIVED TITLE: <br /> UNITIIVUSTIINSP(rev 724102) <br />
The URL can be used to link to this page
Your browser does not support the video tag.