Laserfiche WebLink
ti SAN JOAQUIN COUNTY ~ <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209) 468-3420 Fax: (209)468-3433 Web:www.sogov.orci/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> Qui O� Cir sh o- - Zp � <br /> Facility address: UST#I <br /> 0-1 C.i GadQ/V1/v` & < ir0 tr"tIT/r�l Ve4O_1 Product <br /> Facility contact: Title: Phone: [� <br /> Monitoring pane Piping system: Overfill prevention: Violations: <br /> �� `2�c,� re ❑Suction O Gravity echanical Mt-RDetect CM2-RPrev OM3-Both <br /> --:020 ❑Audible/visual <br /> Inspection type: XDp.e�sktnated ope ator: (�ObtD ICC exp.date: <br /> �outine Clufondoring Certification - Installation ❑Other �1 IU1�1.y��iy (obi u <br /> On site Service Technician's name: ICC exp.date: Manufacturer's t� Ing. V—' �� <br /> covin Milburn 6� �q � obt� QST TiV Taw r <br /> # Code Section VIOLATIONS V R <br /> HSC=CA Health&Safety Code; CCR=CA Code of Regulations;V=Violation; RV=Re eat Violation V <br /> I I HSC 25284 No permit tooperate <br /> Secondary containment: (a)test not performed; (e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test ) <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current or approved by the EHD <br /> 6 CCR 2712(i) Monitoring Ian, response plan, and/oroperating permit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'h (M+) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results <br /> of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed M+ <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST M+ <br /> 11 CCR 2630(d) UST monitoring.equipment is not installed or maintained to detect a leak at the earliest opportunity(MI) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M+) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (m+) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636 c 1 All releases in secondary piping do not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi M+ <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means (1612) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2 <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (1612) <br /> 21 HSC 25291(e) Water in 20 containment not removed, analyzed&properly disposed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight (M+) <br /> 22 CCR 2650 hours was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCRCC2715 a Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b R 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EHD ins or. Re by: Title: <br /> ip1U <br /> EHD 23-02-002 REV s/10 Page 1 UST INSPECTION REPORT <br />