My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO 2006 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:03:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2012
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\707\PR0505151\COMPLIANCE INFO 2006 - 2012 .PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2012
QuestysRecordDate
7/19/2016 8:32:58 PM
QuestysRecordID
3145718
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
351
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
isdYC <br /> Page 4 of 8 AF~ <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: u Sump Manufacturer IM Industry Standard u Professional Engineer <br /> El Other(Specify) <br /> Test Method Used: u Pressure Cl Vacuum u Hydrostatic <br /> u Other(Specify) <br /> Test Equipment Used: Caldwell Equipment Resolution: <br /> 8 F-Sump 1 87-Sump 2 sump Sump <br /> Sump Diameter: 42" 42" <br /> Sump Depth: <br /> Sump Material: Plastic Plastic <br /> Height from Tank Top to Top of 7„ 7" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 4" 4" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry Dry <br /> Portion of Sump Tested' 2"Above Product 2"Above Product <br /> Does turbine shut down when sump <br /> sensor detects liquid(both product and 0 Yes ❑ No 131 NA O Yes O No IM NA u Yes O No O NA O Yes O No O NA <br /> water)?* <br /> Turbine shutdown response time --Turbine Shut Down done during AMC <br /> Is system programmed for fail-safe p Yes ❑ No ® NA ❑Yes u No 131 NA O Yes u No u NA ❑Yes ❑ No ❑ NA <br /> shutdown?' <br /> Was fail-safe verified to be O Yes u No IM NA O Yes u No ® NA O Yes O No O NA u Yes u No u NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 minutes 5 minutes <br /> test: <br /> Test Start Time: 3:15 PM 3:15 PM <br /> Initial Reading(Ri): 0.0025 0.0025 <br /> Test End Time: 3:45 PM 3:45 PM <br /> Final Reading(RF): 0.0025 0.0025 <br /> Test Duration: 30 minutes 30 minutes <br /> Change in Reading(RF-Ri): 0 0 <br /> Pass/Fail Threshold or Criteria: L10IYes <br /> /16"hr 1/16"hr <br /> Test Result: ass ❑ Fail [K Pass ❑ Fail ❑ Pass ❑ Fail u Pass u Fail <br /> Was sensor removed for testing? ❑ No u NAO Yes O No ❑ NA ❑Yes ❑ No ❑ NA ❑ Yes ❑ No O NA <br /> Was sensor properly replaced after ❑ No O NA 131 Yes u No u NA u Yes u No O NA ❑Yes ❑ No ❑ NA <br /> testing? <br /> Comments (include information on repairs made prior to testing and recommended follow-up for failed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page