Laserfiche WebLink
u �.I <br /> T 2:-UP <br /> PRODUCT CODE 2 <br /> THERMAL COEFF : .000700 <br /> TANK DIAMETER : 120.00 <br /> TANK PROFILE : 20 PTS <br /> FULL VOL' : 5001 <br /> 114.0 INCH VOL : 4905 T 3:DIESEL <br /> 108.0 INCH VOL : 4737 PRODUCT CODE 3 OUTPUT RELAY SETUP <br /> 102.0 INCH VOL : 4526 THERMAL COEFF : .004500 - - - <br /> 96.0 INCH VOL : 4284 TANK DIAMETER : 120.00 <br /> 90.0 INCH VOL : 4018 TANK PROFILE : 20 PTS R 1 :REG <br /> 84.0 INCH VOL : 3734 FULL VOL : 5001 NORMALLY CLOSED <br /> 78.0 1NCH VOL : 3436 114.0 INCH VOL : 4905 <br /> 72.0 INCH VOL : 3129 108.0 INCH VOL : 4737 LIQUID SENSOR ALMS <br /> 66.0 INCH VOL : 2814 102.0 INCH VOL : 4526 L 2:FUEL ALARM <br /> 60.0 INCH VOL : 2497 96.0 INCH VOL : 4284 L S:FUEL ALARM <br /> 54.0 INCH VOL : 2179 90.0 INCH VOL : 4018 L 6:FUEL ALARM <br /> 48.0 INCH VOL : 1865 84.0 INCH VOL : 3734 L 7:FUEL ALARM <br /> 42.0 INCH VOL : 1557 78.0 INCH VOL : 3436 L B:FUEL ALARM <br /> 36.0 INCH VOL : 1260 72.0 INCH VOL : 3129 L 2:SENSOR OUT ALARM <br /> 30.0 INCH VOL : 976 66.0 INCH VOL 2814 L 5:SENSOR OUT ALARM <br /> 24.0 INCH VOL : 711 60.0 '1 NCH VOL 2497 L 6:SENSOR OUT ALARM <br /> 18.0 INCH VOL : 470 54.0 INCH VOL 2179 L 7:SENSOR OUT ALARM <br /> 12.0 INCH VOL : 260 48.0 INCH VOL 1865 L B:SENSOR OUT ALARM <br /> 6.0 INCH VOL : 93 42.0 INCH VOL 1557 L 2:SHORT ALARM <br /> 36.0 INCH VOL 1260 L 5:SHORT ALARM <br /> 30.0 INCH VOL 976 L 6:SHORT ALARM <br /> WATER WARNING 1 .5 24.0 INCH VOL 711 L 7:SHORT ALARM <br /> HIGH WATER LIMIT: 1 .5 18.0 INCH VOL 470 L B:SHORT ALARM <br /> 12.0 INCH VOL 260 <br /> OVERFILL LIMIT 90% 6.0 INCH VOL 93 R 2:SUP <br /> 4503 NORMALLY CLOSED <br /> MAX VOLUME LIMIT: 90% <br /> 4503 WATER WARNING 1 .5 LIQUID SENSOR ALMS <br /> HIGH LEVEL LIMIT: 90% HIGH WATER LIMIT: 1 .5 L 3:FUEL ALARM <br /> 4503 L 5:FUEL ALARM <br /> DELIVERY LIMIT 5% OVERFILL LIMIT 95% L 6:FUEL ALARM <br /> 250 4753 L 7:FUEL ALARM <br /> MAX VOLUME LIMIT: 90% L B:FUEL ALARM <br /> LOW LEVEL LIMIT 250 4503 L 3:SENSOR OUT ALARM <br /> LEAK ALARM LIMIT: 1 HIGH LEVEL LIMIT: 90% L S:SENSOR OUT ALARM <br /> SUDDEN LOSS LIMIT: 20 4503 L 6:SENSOR OUT ALARM <br /> TANK TILT 0.00 DELIVERY LIMIT 5% L 7:SENSOR OUT ALARM <br /> NIAPIfFOLDED TANKS 250 L S:SENSOR OUT ALARM <br /> L 3:SHORT ALARM <br /> TO: NONE LOW LEVEL LIMIT 250 L 5:SHORT ALARM <br /> LEAK ALARM LIMIT: i L 6:SHORT ALARM <br /> LEAK MIN ANNUAL 50 SUDDEN LOSS LIMIT: 20 L 7:SH0RT ALARM <br /> PERIODIC TEST TYPE TANK TILT 0.00 L 9:SHORT ALARM <br /> STANDARD MANIFOLDED TANKS R 3:DIESEL <br /> ANNUAL TEST FAIL TO: NONE NORMALLY CLOSED <br /> ALARM DISABLED LEAK MIN ANNUAL 50 LIQUID SENSOR ALMS <br /> PERIODIC TEST FAIL PERIODIC TEST TYPE L 4:FUEL ALARM <br /> L <br /> ALARM DISABLED STANDARD L 6:FUEL ALARM <br /> 6:FUEL ALARM <br /> GROSS TEST FAIL ANNUAL TEST FAIL L 7:FUEL ALARM <br /> L B:FUEL ALARM <br /> ALARM DISABLED ALARM DISABLED <br /> L 4:SENSOR OUT ALARM <br /> TANK TEST NOTIFY: OFF PERIODIC TEST FAIL L 5:SENSOR OUT ALARM <br /> L 6:SENSOR OUT ALARM <br /> ALARM DISABLED <br /> DELIVERY DELAY 5 MIN L 7:SENSOR OUT ALARM <br /> GROSS TEST FAIL L B:SENSOR OUT ALARM <br /> AL 4:SHORT ALARM <br /> ALARM DISABLED <br /> L 5:SHORT ALARM <br /> TANK TEST NOTIFY: OFF L 6:SHORT ALARM <br /> L 7:SHORT ALARM <br /> DELIVERY DELAY 5 MIN L B:SHORT ALARM <br /> R 4: <br /> NORMALLY OPEN <br /> NO ALARM ASSIGNMENTS - <br />