My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO 2006 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:03:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2012
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\707\PR0505151\COMPLIANCE INFO 2006 - 2012 .PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2012
QuestysRecordDate
7/19/2016 8:32:58 PM
QuestysRecordID
3145718
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
351
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s*qov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> FacilityFacillly 707 N Yosemite Avenue, Manteca Dt,: 1O° Oct 24, 2012 <br /> Name: Quick:-kleen Address: Dale: <br /> VIOLATIONS <br /> HSC=CA HeaXh antl SaF Code;CFR=Code of Federal Regulations <br /> # C1 C2 M Code Section Ci=Class 1 violation;C2=Class 2 vidation;M=Minor viola..... <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) IM11 <br /> 703 CCR 2643(d) Tdennial line test for conventional suction piping not pertormed(pre-January 1,1984) (M1) <br /> Other violations <br /> 999 Other See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1 CLASS II,or MINOR-Notice to Comply) <br /> 104. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. Complete and submit a copy of the <br /> financial responsibility within 30 days of receiving this report. Received 2 set of financial responsibility <br /> certification dated 9/12/11 and 9/12/12, during inspection. <br /> 305. The Diesel turbine sensor failed to clear out of alarm when tested to ensure continuous monitoring <br /> of the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm <br /> or stop the flow of product at the dispenser when it detects a leak. Correct immediately by having a <br /> properly licensed, trained, and certified contractor replace the failed component with a functional <br /> component (LG 113-x listed, if applicable) and obtain a permit within 1 business day from the EHD. If <br /> the failed component can't be replaced immediately, there is a possibility that the diesel UST system <br /> may be red tagged to prevent fuel inputs. <br /> 310. Liquid was observed in the diesel STP sump. If water could enter into the secondary containment <br /> by precipitation or infiltration, it must be removed and disposed of properly. Immediately remove this <br /> liquid, make a hazardous waste determination per Title 22 hazardous waste regulations, and manage it <br /> accordingly. Ensure that all the sumps are maintained free of liquid. Technician removed the water and <br /> put it in the facility's hazardous waste drum. <br /> Notes <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation to the EHD within 30 days of receiving <br /> this report. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> ReceMe4 Title: <br /> J/ fh, G� uGeh <br /> EHD 23-02 Rev 04119/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.