COMPLIANCE INFO 1985-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
853
>
2300 - Underground Storage Tank Program
>
PR0231460
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 2:52:58 PM
Creation date
11/8/2018 10:04:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231460
PE
2381
FACILITY_ID
FA0001369
FACILITY_NAME
7-ELEVEN INC. STORE #21756
STREET_NUMBER
853
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
853 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\853\PR0231460\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
8/10/2017 4:54:42 PM
QuestysRecordID
3567749
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> California Edition:September 1997 <br /> Vaporless Manufacturing <br /> Vaporless LD 2000E and LD 2000E-S <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification: Leak rate of 3.0 gph with Pp=100% and PFA=0% <br /> Leak Threshold: 2.0 gph. A leak is declared if the output of the measurement system equals or exceeds <br /> this threshold. <br /> Applicability: Gasoline, diesel, aviation fuel and solvents. <br /> Specification: System tests flexible pipelines. <br /> Tests are conducted at operating pressure. <br /> Pipeline Capacity: Maximum of 59.6 gallons. <br /> Waiting Time: None between dispensing and testing. <br /> None between delivery and testing. <br /> Test Period: Response time is 30 seconds. <br /> System Features: Permanent installation on pipeline. <br /> Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> LD2000E - restricts flow to dispenser if leak is declared. <br /> LD2000ES -pump shutoff if leak is declared. <br /> Calibration: System must be checked annually for capability of detecting a line leak of <br /> 3.0 gph. <br /> Comments: Enviroflex piping with a bulk modulus* of 1,352 psi was used during evaluation. <br /> *See glossary. <br /> Vaporless Manufacturing Evaluator: Ken Wilcox Associates <br /> 9234 E. Valley Rd., Suite C Tel: (816)443-2494 <br /> Prescott Valley, AZ 86314 — <br /> Tel: (602)775-5191 Date of Evaluation: 12/11/92 <br /> 270 <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of <br /> the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.