853
>
2300 - Underground Storage Tank Program
>
PR0231460
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 2:52:58 PM
Creation date
11/8/2018 10:04:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231460
PE
2381
FACILITY_ID
FA0001369
FACILITY_NAME
7-ELEVEN INC. STORE #21756
STREET_NUMBER
853
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
853 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\853\PR0231460\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
8/10/2017 4:54:42 PM
QuestysRecordID
3567749
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16. • ( Tanks subject to float. [Section 2635 (a) (7)I t <br /> C4 A. Anchored by deadman or slab. <br /> « B. Anchors to be installed as specified by manufacturer. <br /> �D C. Installation details provided on plans. <br /> D. Calculations provided. <br /> 17. SPILL AND OVERFILL PREVENTION <br /> OC Underground storage tank equipped with spilt container and an overfill prevention system. (detail drawing of spill <br /> container(s)/piping sump(s) required, including tank fill and all openings). <br /> 04 A. Spill container (Section 2635 (b) (1)1. <br /> If made of metal, exterior wall protected from galvanic corrosion. <br /> 0f Capacity: (minimum of five gallons) S 1:2110n <br /> N Equipped with a drain valve which allows drainage of spilL into primary container. <br /> M Manufacturer: Fo R1GG'o <br /> OC B. Overfill prevention system does not allow for manual override and meets one of the foLLowing requirements: <br /> (1) Alert transfer operator at 90% full by restricting the flow into the tank or triggering an audible <br /> and visual alarm [Section 2635(b)(2)(A)l . <br /> Manufacturer: em(,o Wheaton Made l:: 1100 <br /> _ (2) Restrict delivery flow to the tank 30 minutes before overfill when tank is filled at no more than <br /> 95% capacity and activates an audible alarm at Least five minutes before overfill [Section 2635 <br /> (b) (2) .(8)1. <br /> Manufacturer: Model: <br /> (3) Provide positive shut off at no more than 95% capacity [Section 2635 (b) (2) (C)1- <br /> Manufacturer: Model: <br /> _ (4) Provide positive shut-off of flow to the tank so that the fittings on top of the tank are not <br /> exposed to the product overfilling (Section 2635 (b) (2) (D)I. <br /> Manufacturer: Madel: <br /> 18. PIPING INFORMATION (Pfimay/ �•• ffodud) <br /> PIPING INFORMATION TANK# OI TANK# OLZJ TANK# TANK# <br /> DISTANCE from <br /> DISPENSER to TANK <br /> MANUFACTURER -Total Gantaihmer[-t- <br /> SYSTEM TYPE '' PrztturG <br /> CONSTRUCTION ** Double Wall <br /> MATERIAL * F:I&dble, non -Med'a1tG (enviroflex� <br /> LEAK DETECTION SYSTEM Tidal Ef95 s Sl'em 11ne 1>✓ak dete 'or'ci <br /> 100% METHANOL COMPATIBILITY YES NO <br /> CORROSION PROTECTION YES NO <br /> • System Type; suction, pressure, and gravity <br /> ** Construction: single-walled, double-walled, Lined-trench, etc. <br /> .� Material Type; steel with cathodic protection, stainLess-steeL, fiberglass reinforced plastic. <br /> 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.