My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
853
>
2300 - Underground Storage Tank Program
>
PR0231460
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 2:52:58 PM
Creation date
11/8/2018 10:04:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231460
PE
2381
FACILITY_ID
FA0001369
FACILITY_NAME
7-ELEVEN INC. STORE #21756
STREET_NUMBER
853
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
853 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\853\PR0231460\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
8/10/2017 4:54:42 PM
QuestysRecordID
3567749
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Nominal Nominal Nominal Nominal Wall Nominal Mill Test External Pressure <br /> Pipe Size"' I.D. O.D. Thickness Weig9ht Pressure-Temp. Pressure Max.Rating(psig/MPa) Lenggdom ths <br /> (in.) (in./nm) (in./:im) (in./nm) (lbs:(L/`.g-m) Max.Rating (psig) 75'F/24 C 150`F/66`C (ft. in) <br /> 2.235 2.375 0.070 0.4 250 A @ 150'F 375 88 I <br /> 2 xi.,: c0..i3 '..-S ".•a0 '•.i2 P7�i 66.5-C 2.59 .61 54 46 7.6 9.07 <br /> 3 3.360 3.500 0.070 0.6 175 psig @ 150°F I 300 29 24 15 25 30 <br /> 33.34 33.60 8 ?So 1.21 >.IPa 66.5`C 2.07 .20 .I7 4.6 7.6 9.1 <br /> 4 4.360 4.500 0.070 0.8 125 psig @ 1 SO°F 265 34 30 15 25 30 <br /> IiO.;4 i14.:0 L;3 ... 0.8 1.83 .23 .21 4.6 7.6 9.1 <br /> Bending Radius,Minimum <br /> Nominal <br /> PROPERTY 2',3',4'RED THREAD'IIA Pipe Pipe Size 2' 3' 4' <br /> psi @ 75°F MPa 24,C psi @ 75`F t,IPa @ 66.5-C inches <br /> Axial Tensile(ASTM D2105) FFt. 75 105 140 <br /> Ultimate Stress 15,200 iO4a 13,300 91.7 <br /> Design Stress 3,800 . '6._ 3,325 22.9 <br /> Modulus of Elasticity 1.80 x 10' 124'1 1.4 x 10' 9653 m 22.9 32.0 42.7 <br /> Axial Compression(ASTM D695) 33,300 25,600 177.0 <br /> Ultimate Stress 8,300 ' ' 6,400 44.1 <br /> Design Stress 1.26 x 10' 665" .89 x 10' 6136 (1)All values except pressure-temperature <br /> Modulus of Elasticity maximum rating are nominal values. <br /> Beam Bending(SFPTM) Tolerances or maximum/minimum limits <br /> Ultimate Stress 23,000 j4%." NA NA can be obtained from Smith Fiberglass <br /> Design Stress" 2,900 Z". 1,800 1?.; Products Inc <br /> Modulus of Elasticity 2.18 x 10' i 503 29 <br /> : 1.79 x 10' 142 (2)All sizes can accept full vacuum pressures at <br /> (Long Termper ASTM D2925) maximum temperature ratings. <br /> (3)UL Listed 5'secondary containment piping <br /> Hydrostatic Burst(ASTM D1599) and Non-UL Listed 6'secondary <br /> Ultimate Hoo containment piping are also available from <br /> Tensile a Hoopress 35,000 241.: 41,000 '83.0 Smith Fiberglass Products Inc. <br /> (4)Ultimate and allowable design stresses are <br /> Hydrostatic Design(ASTM D2992) based on minimum reinforced wall <br /> Procedure A thickness.Pipe is manufactured in _ <br /> Cyclic 150 x 10' '" 10,450 °2.1 compliance with AS D2996. _ <br /> Cycles (5) Design bending stress is 1/8 of ultimate to , <br /> account for combined strew(i.e.bending <br /> Coefficient of Linear 0.88 x 10''in./in.r'F and pressure). <br /> Thermal Expansion(SFPTM) .55. '-) -m mm C (6)For RED 7HREAD'If pipe the hydrostatic <br /> cyclic esign stress was determined at 150' <br /> Specific Gravity 1,8 and 200'F,per ASTM D2992 Procedure A. <br /> Flow Factor Based on this data,the extrapolated value at <br /> Hazen-Williams Coefficient 150 75°F is 13,040 psi. <br /> It is the policy of Smith Fiberglass Products to improve its products continually. In accordance with that policy; the <br /> right is reserved to make changes in specifications, descriptions and illustrative material contained in this manual as' <br /> conditions warrant. The information contained herein is general in nature and is not intended to express any <br /> warranty of any type whatsoever nor shall any be implied. <br /> •...r. <br /> 1PEh A1777 . UL 1509001 <br /> SMITH FIBERGLASS PRODUCTS INC. <br /> Little Rock,Arkansas <br /> SMITH RIBI)ERCLASS PROIDUCTS INC. <br /> A Subsidiary of A.O. Smith Corporation <br /> 2700 West 65th Street• Little Rock,Arkansas 72209-8592 •Telephone(501)568-4010 • FAX(501)568-4465 <br /> cCopyright 1992 Smith Fiberglass Products Inc. <br /> and"Trademarks or Smith Fiberglass Products Inc. PRINTED IN U.S.A. 15M1194 <br />
The URL can be used to link to this page
Your browser does not support the video tag.