Laserfiche WebLink
-- - - - - <br /> Facility name: Insuection date: <br /> Costco Gasoline Facility #658 1 September 28, 2010 <br /> Facility address: UST# 1 2 3 <br /> 3250 W. Grant Line Rd., Tracy 87 87, 91. <br /> Facility contact: Title: Phone: <br /> Dennis Bock Compliance Mgr. (425)427-7653 <br /> ' - .. .._.. i Piping system: �6vme.Z",anical <br /> l prevention: Violations: <br /> Veeder-Root TLS-350 1❑XPressurizedauction❑Graviry [1101-RDeted❑M2-RPrev❑M3-Both j <br /> ❑X Audible/visual <br /> (inspection type: Designated operator: ICC exp.date: <br /> QRoutlne Qmonitoring Certification L]Installation E]Other JhustinAbdela 9/26/11 <br /> On site Service Technician's name: ICC exp.date: Manufacturer's training: <br /> Isaac Anderson 6/9/12 VMI x. 3/10/11 VR x. 8/5/12 <br /> _ VIOLATIONS = <br /> HSC=CA Health&Safety Code: CCR=CA Code of Regulations; V=Violation: RV=Re eat Violation <br /> 1 HSC 25284 No permit tooperate <br /> I <br /> conducting the test <br /> 3 CCR 2711 b) Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 6 CCR 2712(i) Monitoring plan,response plan,and/oroperating permit and all conditions not onsite <br /> i <br /> results of inventory readin s and reconciliations <br /> 8 CCR 2643(d) Daily monitorinq of suction piping(pre-January1, 1984)not performed (Mt) <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST Mt <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest o ortunit IMt) <br /> (Mt) <br /> containment <br /> - Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (Mt) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sum <br /> 17 CCR 2636(f)(2)__-_ Line leak detectors)not installed or failed to detect a 3-gallon per.hour leak at 10 psi (Mt) <br /> (11112) <br /> -"- to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section 111112) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction in ) tMz) <br /> F45 1-a=_ is Water in 2'containment not removed,analyzed&properly disposed of <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight (M1) <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a I _CCR [715;a1 Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b ;esi nated operator did not possess a current ICC UST System Operator certification <br /> EHD ived by: Title: <br />