My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 4:48:12 PM
Creation date
11/8/2018 10:21:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2006-2012.PDF
QuestysFileName
COMPLIANCE INFO 2006-2012
QuestysRecordDate
7/5/2017 10:08:33 PM
QuestysRecordID
3482644
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sep 25 06 01:22p Mike Dotten 209-533-2650 p.1 <br /> 1-we <br /> Alltech Petro Inc. <br /> 17759 Buttercup Circle, Sonora, CA 95370 <br /> Phone: 209-532-7320; Fax: 209-533-2650 <br /> California Contractor 623541 A-Haz <br /> Mike@AlltechPetro.com. <br /> MONITORING SYSTEM CERTIFICATION �FMA <br /> A. General Information <br /> Facility Name: Costco# Costco 658 Tracy Date of Testing/Servicing: September 12, 2006 <br /> Facility Address: 3250 W Grant Line Rd., Tracy CA 95304 <br /> Service Station Supervisor: Robert Mendoza Hut Phone: 834-1247 Warehouse Phone. 830-5343 <br /> LIA: San Joaquin Health; Inspector: Willy Ng; LIA Phone: 468-3448;LIA Fax: 468-3433 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> B. Inventory of Equipment Tested/Certifred: <br /> Tank to:Regular I Tank Tank m:Regular 2 Tank <br /> ®in-Tank Gauging Probe. Model:Mag I S In-Tank Gauging Probe_ Model:Mag 1 <br /> ®Annular Space Sensor, Model:Single-Float Brine S Annular Space Sensor. Model Single-Float Brine <br /> ®Piping Sump Seasor(s). Model:Discriminating Sensor ®Piping Sump Sensor(s). Model:Discriminating Sensor <br /> Fill Sump Sensor(s). Model:Discriminating Sensor ®Fill Sump Sensor(s). Model:Discriminating Sensor <br /> ®Mechanical Line Leak Detector. Model:Vaporless ®Mechanical Line Leak Detector. Model:Vaporless <br /> ®Tank Overfill/High-Level Sensor. Model:V-R Audible ®Tack Overfill/High-Level Sensor. Model:V-R Audible <br /> ® <br /> Fillspill Bucket Tested: ®Pass ❑Fail M Fillspill Bucket Tmhed: ®Pass []Fail <br /> ® Fire extinguishers inspected and ed: MOK ❑Not OK S Fire extinguishers inspected and ed: ROK ❑Not OK <br /> Tank m:Premium Tank: Tank ID:None <br /> ®In-Tank Gauging Probe. Model:Mag 1 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space Sensor. Model:Single-Float Brine ❑Annular Space Sensor. Model: <br /> ®Piping Sump Sensor(s). Model:Discriminating Sensor ❑Piping Sump Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model:Discriminating Sensor ❑Fill Sump Sensor(s). Model: <br /> S Mechanical Line Leak Detector, Model:Vaporless ❑ Line Leak Detector. Model: <br /> S Tank Overfill/High-Level Sensor. Model:V-R Audible ❑Tank Overfill/High-Level Sensor. Model: <br /> ® <br /> Fillspill Bucket Tested: []Pass ®Fail ❑Fillspill Bucket Tested: ❑Pass []Fail <br /> ® Fire extin 'stets in ected and[a ed: MOK ❑Not OK ❑ Fire extinguishers inspected and ed; ❑OK []Not OK <br /> Dispenser ID: 1&2 19 Sump:®Dry[]Water❑Product Dispenser m:3&4 M Sump:MDry❑Water❑Product <br /> S Dispenser Containment Sensor(s). Model:Non-Discriminating S Dispenser Containment Sensor(s). Model:Non-Diseriminating <br /> S Shear Valve(s) (Functional test) S Shear Valves) (Functional test) <br /> S Fire extinguisher inspected and : MOK ❑Not OK S Fire extinguisher inspected and to d: SOK ❑Not OK <br /> Dispenser M:5&6 M Sump:®Dry❑Water❑Produot Dispenser ID:7&8®Sump:MDry❑Water❑Product <br /> S Dispenser Containment Sensor(s). Model:Non-Discriminating S Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> S Shear Valve(s) (Functional test) S Shear Valve(s) (Functional test) <br /> S Fire extinguisher inspected and to OK ❑Not OK S Fire extinguisher iected and : MOK ❑Not OK <br /> Dispenser ID:9&10 M Sump:®Dry❑Water❑Product Dispenser ID:11&12 M Sump:MDry[]Water❑Product <br /> S Dispenser Containment Senser(s). Model:Non-Discriminating ®Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) S Shear Valve(s) (Functional test) <br /> S Fire eXtiagaishcr inspected and tagged: ®OK ❑Not OK S Fire extinguisher inspected and : MOK ❑Not OK <br /> Dispenser ID: ❑Sump: []Dry❑Water❑Product Dispenser ID. ❑Sump:❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑ Fire extinguisher inspected and ed: ❑OK ❑Not OK I ❑ Fire extinguisher inspected and ed: ❑OK []Not OK <br /> C. Certification - I eery that the equipment identified in this document was irepected/serviced in accordance with the manufacturers' guidelines. <br /> Attached to this Certirkaattiioonn�is Plot Plan showing the tayout of monitoring equipment For any equipment cepahk orgeneratiag such reports,I hav <br /> also attached a copy Of the Syste et-u ®Alarm history report e <br /> Technician: Mike Dotteo,California Contractor 623541 A-Flaz <br /> Certification: Veeder-Root:006-05-0789;Level 4. ;ICC UST Service Teehniciar 0 5259412-OT. <br />
The URL can be used to link to this page
Your browser does not support the video tag.