Laserfiche WebLink
Sep 25 06 01:22p Mike Dotten 209-533-2650 p.1 <br /> 1-we <br /> Alltech Petro Inc. <br /> 17759 Buttercup Circle, Sonora, CA 95370 <br /> Phone: 209-532-7320; Fax: 209-533-2650 <br /> California Contractor 623541 A-Haz <br /> Mike@AlltechPetro.com. <br /> MONITORING SYSTEM CERTIFICATION �FMA <br /> A. General Information <br /> Facility Name: Costco# Costco 658 Tracy Date of Testing/Servicing: September 12, 2006 <br /> Facility Address: 3250 W Grant Line Rd., Tracy CA 95304 <br /> Service Station Supervisor: Robert Mendoza Hut Phone: 834-1247 Warehouse Phone. 830-5343 <br /> LIA: San Joaquin Health; Inspector: Willy Ng; LIA Phone: 468-3448;LIA Fax: 468-3433 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> B. Inventory of Equipment Tested/Certifred: <br /> Tank to:Regular I Tank Tank m:Regular 2 Tank <br /> ®in-Tank Gauging Probe. Model:Mag I S In-Tank Gauging Probe_ Model:Mag 1 <br /> ®Annular Space Sensor, Model:Single-Float Brine S Annular Space Sensor. Model Single-Float Brine <br /> ®Piping Sump Seasor(s). Model:Discriminating Sensor ®Piping Sump Sensor(s). Model:Discriminating Sensor <br /> Fill Sump Sensor(s). Model:Discriminating Sensor ®Fill Sump Sensor(s). Model:Discriminating Sensor <br /> ®Mechanical Line Leak Detector. Model:Vaporless ®Mechanical Line Leak Detector. Model:Vaporless <br /> ®Tank Overfill/High-Level Sensor. Model:V-R Audible ®Tack Overfill/High-Level Sensor. Model:V-R Audible <br /> ® <br /> Fillspill Bucket Tested: ®Pass ❑Fail M Fillspill Bucket Tmhed: ®Pass []Fail <br /> ® Fire extinguishers inspected and ed: MOK ❑Not OK S Fire extinguishers inspected and ed: ROK ❑Not OK <br /> Tank m:Premium Tank: Tank ID:None <br /> ®In-Tank Gauging Probe. Model:Mag 1 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space Sensor. Model:Single-Float Brine ❑Annular Space Sensor. Model: <br /> ®Piping Sump Sensor(s). Model:Discriminating Sensor ❑Piping Sump Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model:Discriminating Sensor ❑Fill Sump Sensor(s). Model: <br /> S Mechanical Line Leak Detector, Model:Vaporless ❑ Line Leak Detector. Model: <br /> S Tank Overfill/High-Level Sensor. Model:V-R Audible ❑Tank Overfill/High-Level Sensor. Model: <br /> ® <br /> Fillspill Bucket Tested: []Pass ®Fail ❑Fillspill Bucket Tested: ❑Pass []Fail <br /> ® Fire extin 'stets in ected and[a ed: MOK ❑Not OK ❑ Fire extinguishers inspected and ed; ❑OK []Not OK <br /> Dispenser ID: 1&2 19 Sump:®Dry[]Water❑Product Dispenser m:3&4 M Sump:MDry❑Water❑Product <br /> S Dispenser Containment Sensor(s). Model:Non-Discriminating S Dispenser Containment Sensor(s). Model:Non-Diseriminating <br /> S Shear Valve(s) (Functional test) S Shear Valves) (Functional test) <br /> S Fire extinguisher inspected and : MOK ❑Not OK S Fire extinguisher inspected and to d: SOK ❑Not OK <br /> Dispenser M:5&6 M Sump:®Dry❑Water❑Produot Dispenser ID:7&8®Sump:MDry❑Water❑Product <br /> S Dispenser Containment Sensor(s). Model:Non-Discriminating S Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> S Shear Valve(s) (Functional test) S Shear Valve(s) (Functional test) <br /> S Fire extinguisher inspected and to OK ❑Not OK S Fire extinguisher iected and : MOK ❑Not OK <br /> Dispenser ID:9&10 M Sump:®Dry❑Water❑Product Dispenser ID:11&12 M Sump:MDry[]Water❑Product <br /> S Dispenser Containment Senser(s). Model:Non-Discriminating ®Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) S Shear Valve(s) (Functional test) <br /> S Fire eXtiagaishcr inspected and tagged: ®OK ❑Not OK S Fire extinguisher inspected and : MOK ❑Not OK <br /> Dispenser ID: ❑Sump: []Dry❑Water❑Product Dispenser ID. ❑Sump:❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑ Fire extinguisher inspected and ed: ❑OK ❑Not OK I ❑ Fire extinguisher inspected and ed: ❑OK []Not OK <br /> C. Certification - I eery that the equipment identified in this document was irepected/serviced in accordance with the manufacturers' guidelines. <br /> Attached to this Certirkaattiioonn�is Plot Plan showing the tayout of monitoring equipment For any equipment cepahk orgeneratiag such reports,I hav <br /> also attached a copy Of the Syste et-u ®Alarm history report e <br /> Technician: Mike Dotteo,California Contractor 623541 A-Flaz <br /> Certification: Veeder-Root:006-05-0789;Level 4. ;ICC UST Service Teehniciar 0 5259412-OT. <br />