My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 4:48:12 PM
Creation date
11/8/2018 10:21:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2006-2012.PDF
QuestysFileName
COMPLIANCE INFO 2006-2012
QuestysRecordDate
7/5/2017 10:08:33 PM
QuestysRecordID
3482644
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209) 468-3420 Fax:(209)468-3433 Web:www.siaov.orD/ehd/unitiii.htrnl <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Faciame.lity Costco Gasoline Facility #658 lacim,B: 3250 West Grant Line Road, Tracy D�pe�tion Sep 21, 2011 <br /> N <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Heath end Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Plesaurlred Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (Ni <br /> 703 CCR 2643(4) Triennial line test for conventional suction piping not performed(pre-January 1, 1964) (Mf) <br /> Other Vloletlona <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS L CLASS II,or MINOR-"g— <br /> LIST <br /> g—UST Inspection: Routine and Annual Monitoring System Certification <br /> 206. The designated operator employee training for several fuel station attendants were not performed <br /> on an annual basis or unclear if training was received. <br /> There is no documented training for the following employees: <br /> - Jesse Johnson, Michaell Lwatate, Jayson Thompson, Ashley Deaton, Joey Christmas, Joseph Jorge, <br /> Seth Anderson, Maria Bermudez, Leo Bobadilla, Andres Cabrera, Jennifer Eborlas, David Elizondo, <br /> Ashley Fernandez, Jeff Fernandez, Roy Hampton, Donald Jeffrey, Chase Chaynez, Eric Williams, Erik <br /> Kerbel, Adrian Bobadilla, Alex DaSilva <br /> The following employees have not received their annual training within the last 12 months (last training <br /> date): <br /> - Christine Hernandez (03/2010), Elgie Grant (07/10), Bryan Woods (7/10), Cameron Cardoza (07/10), <br /> Eddie Ceron (02/10) <br /> The designated operator shall train facility employees for which he or she is responsible in the proper <br /> operation and maintenance of the UST system once every 12 months. The training shall include, but is <br /> not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and <br /> submit a copy of the training records to the EHD. <br /> Submit to SJC EHD within 30 days (10/21/11): <br /> 1. one copy of the completed "Return to Compliance Certification" form <br /> 2. a written corrective action statement for the above violation how to ensure employees receive their <br /> annual training <br /> 3. Designated Operator's employee training log <br /> ALL EHD STAFF TIME ASSOCIATED HATH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL 13E BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> I^ePeda Received B TNe: <br /> EHD 23-02 Rev 09/011 1 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.