Laserfiche WebLink
r: <br /> Alltech Petro Inc. OCT 072010 <br /> P.O. Box 4208, Sonora, CA 95370 <br /> Phone: 209-532-7320; Fax: 209-533-2650 SANJOAQU; <br /> ] cfhmail( a4me com Contractor 623541 A-Hoz l�a C ,'SR7MEP IN <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: Costco#658 Tracy Date of Testing/Servicing: September 28,2010 <br /> Facility Address: 3250 W Grant Line Rd.,Tracy CA 95304 <br /> Service Station Supervisor: Robert Mendoza Hut Phone: 209-834-1247 Warehouse Phone: 830-5343 <br /> LIA: San Joaquin Health; Inspector: Stacy Rivera; LIA Phone: 209468-3440; LIA Fax: 209468-8392 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> B. Inventory of Equipment Tested/Certified: <br /> Tank ID:Regular 1 Tank Tank ID:Regular 2 Tank <br /> M In-Tank Gauging Probe. Model:Mag 1 M In-Tank Gauging Probe. Model:Mag 1 <br /> ®Annular Space Sensor. Model:794380-301 ®Annular Space Sensor. Model:794380-301 <br /> ®Piping Sump Sensor(s). Model:793380-352 ®Piping Sump Sensor(s). Model:793380-352 <br /> ®Fill Sump Sensor(s). Model:794380-352 ®Fill Sump Sensor(s). Model:793380-352 <br /> ®Mechanical Line Leak Detector. Model:VR PLLD ®Mechanical Line Leak Detector. Model:VR PLLD <br /> ®Tank Overfill/High-Level Sensor. Model:V-R Audible ®Tank Overfill/High-Level Sensor. Model:V-R Audible <br /> ®Fillspill Bucket Tested: ®Pass ❑Fail ®Fillspill Bucket Tested: ®Pass ❑Fail <br /> ® Fire extinguishers inspected and tagged: MOK ❑Not OK ® Fire extinguishers ins ted and tagged: MOK ❑Not OK <br /> Tank ID:Premium Tank: Tank ID:None <br /> M In-Tank Gauging Probe. Model:Mag 1 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space Sensor. Model:794380-301 ❑Annular Space Sensor. Model: <br /> ®Piping Sump Sensor(s). Model:793380-352 ❑Piping Sump Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model:793380-208 ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model:VR PLLD ❑ Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model:V-R Audible ❑Tank Overfill/High-Level Sensor. Model: <br /> ®Fillspill Bucket Tested: ®Pass ❑Fail ❑Fillspill Bucket Tested: ❑Pass ❑Fail <br /> ® Fire extinguishers insviuccteciand tagged: MOK []NotOK ❑ Fire extinguishers inspected and tagged: ❑OK []Not OK <br /> Dispenser ID: 1&2 M Sump:®Dry❑Water❑Product Dispenser ID:3&4 M Sump:®Dry❑Water[]Product <br /> M Dispenser Containment Sensor(s). Model:794380-208 M Dispenser Containment Sensor(s). Model:794380-208 <br /> M Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> ® Fire extinguisher inspected and tagged: MOK []Not Ok M Fire extinguisher inspected and tagged: MOK ❑Not OK <br /> Dispenser ID:5&6 M Sump:®Dry❑Water❑Product Dispenser ID:7&8 M Sump:MDry❑Water❑Product <br /> M Dispenser Containment Sensor(s). Model:794380-208 M Dispenser Containment Sensor(s). Model:794380-208 <br /> ®Shcar Valves) (Functional test) M Shear Valve(s) (Functional test) <br /> M Fire extinguisher inspected and tagged: MOK ❑Not OK M Fire extinguisher inspected and tagged: MOK ❑Not OK <br /> Dispenser ID:9&10 M Sump:MDry❑Water❑Product Dispenser ID: 11&12 M Sump:MDry❑Water❑Product <br /> ®Dispenser Containment Sensor(s). Model:794380-208 M Dispenser Containment Sensor(s). Model:794380-208 <br /> M Shear Valves) (Functional test) ®Show Valve(s) (Functional test) <br /> M Fire extinguisher inspected and tagged: MOK ❑Not OK M Fire extin isher instiected and tagged: MOK ❑Not OK <br /> Dispenser ID:NONE❑Sump:❑Dry❑Water[]Product Dispenser ID:NONE❑Sump: []Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valvc(s) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑ Fire extinguisher inspected and tagged: ❑OK [--]Not OK ❑ Fire extinguisher inspected and tagged: ❑OK []Not OK <br /> C. Certification - 1 certify that the equipment identified in this document was impected/serviced in accordance with the manufacturers' guidelines. <br /> Attached to this Certification is a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,1 have <br /> also attached a copy of the report; M System set-up M Alarm history report <br /> Technician: <br /> Date:9/28/10 <br /> Certification: <br /> Veeder-Root 836878,Level 4 ISD; <br /> ICC UST Service Technician#8005930-UT. <br />