My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 4:34:29 PM
Creation date
11/8/2018 10:21:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2013-2015.PDF
QuestysFileName
COMPLIANCE INFO 2013-2015
QuestysRecordDate
7/5/2017 11:14:25 PM
QuestysRecordID
3483232
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. PIPING SUMP TESTING REGEiV�® <br /> Test Method Developed By: ❑ Sump Manufacturer N Industry Standard ❑ ProfiesFEY24IM15 <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ®MWWONMENTAL <br /> ❑Other(Specify) HFA!T,H r1FP4rMApkr <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: <br /> Sump#87-1 Sump# 87-2 Sump# 91 Sump# <br /> Sump Diameter: 48" 48" 48" <br /> Sump Depth: 56" 56" 61" <br /> Sump Material&Manufacturer: Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 30" 22" 16" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 18" 22" 21" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Fair Fair Fair <br /> Portion of S Tested' Above highest Above highest Above highest Above highest <br /> Wrap penetration penetration penemlon penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes[-]No N NA [-]Yes[-]No N NA []YesElNo N NA [_1 Yes[-INoN NA <br /> product and water)? <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe ❑Yes❑No N NA ❑Yes❑No N NA ❑Yes❑No N NA ❑Yes❑No N NA <br /> shutdown? <br /> Was fail-safe verified to be <br /> operational?* [-I Yes ElNo N NA ❑Yes E]No N NA [:]Yes[-INo N NA ❑Yes❑No N NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 30 minutes 30 minutes 30 minutes 30 minutes <br /> test: <br /> Test Start Time: 12:29pm 12:29pm 12:56pm <br /> Initial Reading(RO: 4.8910 1.9416 1.4650 <br /> Test End Time: 12:44pm 12:44pm 1:11pm <br /> Final Reading(RF): 4.8919 1.9428 1.4652 <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-R,): 0.00093 0.00128 0.00020 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: N Pass ❑Fail N Pass ❑Fail N Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? N Yes❑No❑NA NYes❑No❑NA NYes❑No❑NA N Yes❑No❑NA <br /> Was sensor properly replaced and <br /> verified functional after testin ? N Yes❑No❑NA NYes❑No❑NA NYes❑No❑NA N Yes❑No❑NA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />