My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 4:34:29 PM
Creation date
11/8/2018 10:21:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2013-2015.PDF
QuestysFileName
COMPLIANCE INFO 2013-2015
QuestysRecordDate
7/5/2017 11:14:25 PM
QuestysRecordID
3483232
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
..� San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.swaov.Org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Costco Wholesale#658 3250 W GRANT LINE RD, Tracy at <br /> 25 2U14 <br /> UST System Observations <br /> 324 CCR 2635(b) Nospill bucket installed or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 325 1 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ■V ❑R ■COS <br /> 326 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements ❑V ❑R ❑COS <br /> ❑V o ❑COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status <br /> 328 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve u V R u COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R u COS <br /> Other Violations <br /> 2010 See below unlisted Administration/Documentation violation ❑V u R n COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑v o R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 305 VPH monitoring of the interstitial spaces of the UST system is not maintained. The Lubrizol vent sump (1-12)sensor <br /> failed when tested. The sensors monitoring the liquid level in the interstitial space shall be maintained so that a breach <br /> in the primary or secondary containment is detected before the hazardous substance is released into the environment. <br /> The sensor was replaced and retested during the inspection. A"UST Retrofit Verification with Inspector Already Onsite' <br /> form has been completed and provided to the operator and contractor. This is a minor violation. CORRECTED. <br /> 321 All releases in secondary piping do not flow to a collection sump. All jumper hoses in UDCs 1/2 through 7/8 were still <br /> attached and boots were not pulled back, and jumper hoses in UDC 9/10 were disconnected but were pointing upward. <br /> Any potential release from the primary containment into the secondary containment in the product piping does not flow <br /> into a collection sump. All secondary containment systems shall be sloped so that all releases will flow to a collection <br /> sump located at the low point of the underground piping. The technician onsite disconnected all pertinent jumper hoses <br /> and ensured that any potential release from the primary containment into the secondary containment in the product <br /> pi in does flow into a collection sump. This is a Class II violation. CORRECTED. <br /> 325 Spill container failed to contain a minimum capacity of five gallons. The 91-octane spill container was repaired prior to <br /> testing. All spill containers shall have a minimum capacity of five gallons and be capable of containing a spill or overfill <br /> until it is detected or cleaned up. The technician onsite replaced the"O" ring, cleaned the drain valve, and tested the <br /> spill container with passing results. This is a minor violation. CORRECTED. <br /> Overall Inspection Comments: <br /> Consent to perform the inspection, take photos and collect samples was given by Troy Dominici, station <br /> Received by(initial): Inspector: hone: ate: <br /> ELENA MANZO, REHS (209) 953-7699 09/25/2014 <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.