My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 4:34:29 PM
Creation date
11/8/2018 10:21:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2013-2015.PDF
QuestysFileName
COMPLIANCE INFO 2013-2015
QuestysRecordDate
7/5/2017 11:14:25 PM
QuestysRecordID
3483232
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIPHON MANIFOLDED TANKS 8 2:UNLEADED 87B `.IQUID SENSOR SETUP - - <br /> T#: NONE - - - - - - - <br /> LINE MANIFOLDED TANKS TYP:1 .5/21N ENVIRN GFLXD <br /> T#: NONE 1 .5IN DIA LEN: 0 FEET L 1 :87A TANK 1 ANNULAR <br /> TRI-STATE (SINGLE FLOAT) <br /> DELIVERY DELAY 1 MIN 2.xIN DIA LEN: 225 FEET CATEGORY : ANNULAR SPACE <br /> PUMP THRESHOLD 10.00% <br /> 0.20 GPH TEST: REPETITIV <br /> 0.10 GPH TEST: AUTO L 2:87B TANK 2 ANNULAR <br /> SHUTDOWN RATE: 3.0 GPH TRI-STATE (SINGLE FLOAT) <br /> LOW PRESSURE SHUTOFF:YES CATEGORY : ANNULAR SPACE <br /> LOW PRESSURE 5 PSI <br /> T 2:Unleaded <br /> DISPENSE MODE: L 3:PREMIUM ANNULAR <br /> STANDARD TRI-STATE (SINGLE FLOAT) <br /> SENSOR: NON-VENTED CATEGORY : ANNULAR SPACE <br /> PRESSURE OFFSET: O.OPSI <br /> LEAK TEST METHOD MECHANICAL BLENDER: NO <br /> TEST ON DATE : ALL TANK L 4:ADDITIVE ANNULAR <br /> JUN 6, 2008 DUAL POINT HYDROSTATIC <br /> START TIME : DISABLED CATEGORY : ANNULAR SPACE <br /> TEST RATE :0.20 GAL/HR <br /> DURATION : 2 HOURS <br /> TST EARLY STOP:DISABLED L 5:87A FILL SUMP-HYDRO <br /> DW SUMP 2-1 <br /> LEAK TEST REPORT FORMAT CATEGORY : PIPING SUMP <br /> NORMAL <br /> G 3:PREMIUM L 6:87A TANK I STP <br /> TYP:USER DEFINED DUAL FLT. DISCRIMINATING <br /> 1ST LINE LEN: 0 FEET CATEGORY : STP SUMP <br /> 2ND LINE LEN: 320 FEET <br /> 2ND LINE DIAM: 2.00 IN. L 7:87B FILL SUMP-HYDRO <br /> 2ND BULK MOD: 11000 PSI DW SUMP 2-1 <br /> THERMAL COEFF :0.000700 CATEGORY : PIPING SUMP <br /> 0.20 GPH TEST: REPETITIV <br /> 0.10 GPH TEST: AUTO <br /> PRESSURE LINE LEAK SETUP PASSIVE 0.10 GPH: NO L 8:87B TANK 2 STP <br /> SHUTDOWN RATE: 3.0 GPH DUAL FLT. DISCRIMINATING <br /> LOW PRESSURE SHUTOFF:YES CATEGORY : STP SUMP <br /> LOW PRESSURE 5 PSI <br /> 0 I :UNLEADED 87A T 3:Premium <br /> DISPENSE MODE: L 9:PREM FILL SUMP-HYDRO <br /> TYP:USER DEFINED STANDARD DW SUMP 2-1 <br /> IST LINE LEN: 0 FEET SENSOR: NON-VENTED CATEGORY PIPING SUMP <br /> 2ND LINE LEN: 225 FEET PRESSURE OFFSET: O.OPSI <br /> 2ND LINE DIAM: 2.00 IN. <br /> 2ND BULK MOD: 11000 PSI MECHANICAL BLENDER: NO L10:PREMIUM STP <br /> THERMAL COEFF :0.000700 DUAL FLT. DISCRIMINATING <br /> 0.20 GPH TEST: REPETITIV CATEGORY : STP SUMP <br /> 0.10 GPH TEST: AUTO <br /> PASSIVE 0.10 GPH: NO <br /> SHUTDOWN RATE: 3.0 GPH L11 :ADDITIVE STP-HYDRO <br /> LOW PRESSURE SHUTOFF:YES DW SUMP 2-1 <br /> LOW PRESSURE 5 PSI CATEGORY : STP SUMP <br /> T ! :Unleaded <br /> DISPENSE MODE: L126ADDITIVE VENT-HYDRO <br /> STANDARD DW SUMP 2-1 <br /> SENSOR: NON-VENTED CATEGORY : PIPING SUMP <br /> PRESSURE OFFSET: O.OPSI LINE LEAK LOCKOUT SETUP <br /> MECHANICAL BLENDER: NO LOCKOUT SCHEDULE L13:DISPENSER PAN 1-2 <br /> DAILY TRI-STATE (SINGLE FLOAT) <br /> START TIME: DISABLED CATEGORY : DISPENSER PAN <br /> STOP TIME DISABLED <br /> L14:DISPENSER PAN 3-4 <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br /> L15:DISPENSER PAN 5-6 <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.