Laserfiche WebLink
San Joaquin County i <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Costco Wholesale #658 3250 W GRANT LINE RD, Tracy September 23, 2015 <br /> UST System Observations <br /> 319 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) o V o R COS <br /> 320 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion ❑V ❑R D COS <br /> 25290.2(c3) <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump ❑V ❑R ❑COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ■V ■R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep It empty n V o R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons o V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V ❑R u COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden n V ❑R ❑COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status o V o R ❑COS <br /> 329 CCR 2717.1(g) Tampered with red tag ❑V ❑R o COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R n COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms n V ❑R in COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements ❑V n R ❑COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements o V o R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not property sloped or incorrect'located check valve o V o R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation D V o R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V in R ❑COS <br /> 2060 See below Unlisted Design/Construction violation o V o R n COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> ?01 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Alarm logs for the following alarms were not documented by the Costco gas station technician: sensor L 7:87B fill <br /> sump-hydro piping sump sensor out alarm 2/4/2015, Q 3: Premium gross line fail 2/12/2015, and L13: dispenser pan <br /> 1-2 dispenser pan fuel alarm 5/12/2015. Provide the alarm logs to the Environmental Health Dept. if available. <br /> This is a minor violation. <br /> Receiv Inspector: Phone: Date: <br /> (ini GARRETT BACKUS, Lead Senior REHS (209) 468-2986 09/23/2015 <br />