Laserfiche WebLink
ANIL <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Costco Wholesale#658 3250 W GRANT LINE RD, Tracy September 22, 2016 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status V R COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status n V n R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑C05 <br /> 326 HSG 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R D COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSG 25298 Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V D R D COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V D R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed D V D R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R n COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V n R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V o R D COS <br /> 2060 See below Unlisted Design/Construction violation V ❑R c COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> The Lubrizol UST piping and fill sump lid is missing the required gasket between the sump top and the sump lid. <br /> Secondary containment shall be impervious to the liquid and vapor of the substance contained and constructed to <br /> prevent structural weakening as a result of contact with any hazardous substances released from the primary <br /> containment. Have a licensed, certified technician install the gasket and provide a corrective action statement to the <br /> EHD. <br /> This is a repeat violation from last year's inspection, Class 11. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements. <br /> The light used as the external visual part of the overfill prevention system is not currently functional on the UST <br /> system. The light bulb was replaced and retested during the inspection. Violation resolved. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> FA0013810 PRO518288 SCO01 09/22/2016 <br /> EHD 23-01 Rev 09/22/16 Page,3 of 4 Underground Storage Tank Program OIR <br />