My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2023 9:08:35 AM
Creation date
11/8/2018 10:21:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2016 - PRESENT.pdf
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
416
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N sJ OA Q U I N Environmental Health Department <br /> COUNTY Linda Turkatte, RENS, Director <br /> Greatness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada, REHS <br /> Willy Ng, REHS <br /> January 17, 2018 Muniappa Naidu, REHS <br /> Attn: James Alexander <br /> Wayne Perry Inc. <br /> 30 Main Avenue, Suite #5 <br /> COPY <br /> Sacramento, CA, 95838 <br /> Re: Costco Wholesale Corp SR0078543 <br /> 3250 W. Grant Line Road <br /> Tracy, CA. 95304 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br /> application for a permit to replace piping penetrations (icon custom split insert 2.5xDAM Stop) in the <br /> under dispenser containments (UDCs) 112, 314, 718, 9110, replace the Phil-tite (like for like) vapor spill <br /> containers in 87-1 and 87-2 sumps, and the Phil-tite (like for like) fill spill container in the 87-2 sump on <br /> the underground storage tank (UST) system at the above noted address. The permit has been <br /> approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Betty Ho at (209) 468-3455 to arrange the following inspection appointments (a 48- <br /> hour notice is required for inspection appointments). Please be aware that inspections for <br /> emergency work must be scheduled within five days of permit approval. <br /> a. Sensor functionality: Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of <br /> Regulations and the Health & Safety Code. If it is determined that a cold start is necessary, <br /> a copy of the alarm history shall be printed prior to performing the "cold start" of the Veeder <br /> Root system and made available at the time of EHD inspection. <br /> b. If cold started, overfill prevention verification: Verify that external audio and visual alarm <br /> activates when tank is 90% full. <br /> c. Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic test (or <br /> equivalent) of the 87-2 fill sump spill bucket. Proper drainage must also be verified. <br /> d. Flex pipes: verify drainage into each UDC (jumpers if any, must be disconnected) at end of <br /> the secondary containment testing. <br /> e. Primary piping test: Witness tightness test performed by SWRCB licensed tank tester or <br /> receive passing 0.1 gallon per hour test results from the PLLD (if installed). A visual <br /> inspection is required for PLLD tested lines. <br /> f. 24-hour hydrostatic test (or equivalent) on under dispenser containment sumps listed <br /> above. <br /> 9171 9690 0935 0152 1703 68 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.