Laserfiche WebLink
0311912e1B 11:17 2094616342 ELITEIV PAGE 65 <br /> IREG <br /> MAR 2013 <br /> ENNArRO-IJ,`AENTAL <br /> n n&.gnAENT <br /> Sensor Input Box Dimensions <br /> The Sensor Input Box housing dimensions are shown in Figure 1. <br /> `�VEWM-ROOT <br /> 2 TO t SENSOR INPUT 9O% <br /> ILVwftE:�'+V ca2.MM1rcF.w'i' <br /> 'jll(iCutTCCa['.x:ii 4liLFG <br /> o n„ ,3u <br /> tlnseaaenoam.ps <br /> Figure 1. Sensor Input Box dimensions <br /> , <br /> Legend for numbered boxes in Figure t <br /> 1. Cover screws TK 10(2) <br /> 2. 2 conductor(#22 AWG),PVC jacketed cable(6 ft.) <br /> 3. Cord grips bushings and nuts from sensor kits(2 ea.) <br /> 4. #10.32 taptite,Phillips head mounting screws(2) <br /> Installation Procedure <br /> 1 Caution!The total length of cable from the console to the sump junction box and from the junction <br /> box to both sensors cannot exceed 1000 feet. <br /> 1. From the installation kit,install the mini-hydrostatic sensor in the brine sump and either a position sensitive or <br /> sump sensor(as ordered)in the base of the sump as per instructions in the manuals included with thoso <br /> sensors.Do not attach the sensor cables at this time. <br /> 2. Figure 2 shows an example installation of the Sensor€npul Box.Attach the unit where practical to a rigid <br /> support member using appropriate fittings from the universal sensor mounting kit. <br />