Laserfiche WebLink
Z \2 <br /> po m e Z <br /> q� U) O o Q V00 <br /> GRANT LINE RD a- 0 <br /> PROJECT LOCATION AS BUILT � <br /> EXISTING TURBINE EXISTING TANK ANNULAR <br /> SUMP TYP. OF 4 205 w. 11TH ST T T ACY 9� 1)ONESCO^ ,INC. 12/2017 r°-� <br /> (TYP. OF 3) ( ) - I Fn <br /> o >0 <br /> � J <br /> Of W r , <br /> EXISTING FILL SUMP Z Z v <br /> (TYP. OF 3) of w (� Q <br /> o WORK w W J LL <br /> EXISTING < AREA L <br /> TANK #3 0 W Z Q Z <br /> (92 OCTANE) I o " o U Q <br /> 20,000 I <br /> GALLON 0 0 � Q J <br /> =D <br /> 0NOT TO SCALE NOT TO SCALE z 0- V � <br /> C) w � Q Q <br /> VICINITY MAP LOCATOR MAP W HCD (� <br /> cn <br /> a <br /> EXISTING D a W 0 <br /> TANK #2 <br /> (87 OCTANE) i PIPING LEGEND Cs z u <br /> 20,000 o I I W N (n <br /> GALLON ° ° ° 0DO I J T <br /> EXISTING 2" FLEXIBLE DOUBLE WALL PRODUCT PIPING IN 4" GEODUCT ¢ 00 � 0 <br /> I � U <br /> - EXISTING 2" OR S' F.G. DOUBLE WALL VAPOR RECOVERY PIPING Q <br /> EXISTING 3" DOUBLE WALL FIBERGLASS VENT PIPING N <br /> EXISTING <br /> H <br /> TANK <br /> # a <br /> (87 OCTANE) I EXISTING �4 Z <br /> 20,0ADDITIVE INSTALLATION NOTES <br /> GALLON 0 0 O I TANK 1 ,500 <br /> GALLON REMOVE (6) SIX EXISTING "ENCORE 500" DISPENSERS AND REPLACE WITH (6) SIX NEW "GILBARCO ENCORE"-700S <br /> SERIES SINGLE HOSE PER SIDE, 2+0-PRODUCT DISPENSERS AS SHOWN. DISPENSERS TO BE FITTED WITH NEW HEALY <br /> STAGE II HOSES AND NOZZLES, BREAKAWAY VALVES PER CARB VR-202. GENERAL CONTRACTOR TO PURGE LINESI� <br /> THROUGH EACH METER/NOZZLE WITH 50 GALLON PURGE. ANY AIR POCKETS OR START UP PROBLEMS DUE TO M—A N <br /> EXISTING DOUBLE WALL I IMPROPER INSTALLATION OR INCORRECT WIRING THAT DESTROYS ELECTRONICS WILL BE BILLED BACK TO THE O <br /> FIBERGLASS TANKS _ _ I _ _ _ _ O CONTRACTOR. AFTER PURGING THE PRODUCT LINES OF AIR, CONTRACTOR IS TO REPLACE THE FACTORY INSTALLED 00 <br /> (TYP.) I GASOLINE FILTERS WITH THE COSTCO SUPPLIED FILTERS. J 0) <br /> Q Z <br /> EXISTING L FLEXIBLE - - - - - O PERFORM REQUIRED REGULATORY TESTING ON NEW DISPENSERS EQUIPMENT/HARDWARE. REQUIRED REGULATORY (n > 0 <br /> DOUBLE WALL PR \ • • TESTING TO BE COMPLETED BY COSTCO'S 3RD PARTY TESTER, COORDINATED BY CONTRACTOR." <br /> PIPING FLEXIBLE <br /> V <br /> • <br /> EXISTING 4" OVER 3" O\ XISTING 0 Z <br /> DOUBLE WALL O VENT RISERS = W <br /> FIBERGLASS VAPOR ( 3 REMOVE DISPENSER SUMP SENSOR & REPLACE WITH MAG SUMP SENSOR. INSTALL ONE (1) VEEDER-ROOT WIRELESS �L (n <br /> RECOVERY RF TRANSMITTER AT EACH DISPENSER FOR UDC SENSOR. INSTALL ONE (1) VEEDER-ROOT WIRELESS RF TRANSMITTER 0 J Q <br /> ILAT EACH DISPENSER FOR VAPOR FLOW METER. <br /> 0 EXISTING ESO Not Installed V <br /> � � 2 <br /> EXISTING CONTROLLER EXISTING UPGRADE VEEDER-ROOT PANEL SOFTWARE AS REQUIRED FOR ADDITION OF SMART SENSOR MODULES AND WIRELESS <br /> XISTING CANOPY ENCLOSURE • OVERFILL ® RF SYSTEM. PERFORM VEEDER-ROOT COLD START & MONITOR SYSTEM CERTIFICATION. 0 <br /> OVERHEAD EXISTING VEEDER ROOT ALARM / , <br /> ALARM MONITOR U 0 <br /> EXISTING ISLAND SYSTEM, MONITORED 24 (a REMOVE EXISTING VAPOR PRESSURE SENSOR AT DISPENSER. INSTALL NEW VAPOR PRESSURE SENSOR KIT AT VENT STACK. REFER Q <br /> ® HOURS/DAY TO SHEET T-3 FOR DETAILS co <br /> • —EXISTING <br /> HEALY C.A.S <br /> II • O <br /> LL <br /> O0 0 COMPLIANCE NOTESQ �/���I <br /> n n <br /> Lui <br /> 1. ALL DIMENSIONS AND CONDITIONS SHALL BE CHECKED AND VERIFIED IN THE FIELD BEFORE STARTING ANY WORK. ANY ,�� CHRIS M. TEBAL I <br /> LTJ I of DISCREPANCY SHALL BE CALLED TO THE ATTENTION OF THE OWNERS CONSULTANT FOR HIS DECISION BEFORE PROCEEDING WITH <br /> r <br /> THE WORK. C83 15 <br /> O 2• GENERAL CONTRACTOR SHALL OBTAIN NECESSARY PERMIT FROM APPLICABLE AGENCIES FOR EXCAVATIONS OF TRENCHES 5'-0" <br /> OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND. <br /> O T O O 3. ALL MATERIALS SHALL BE COMPATIBLE WITH USE FOR THE INTENDED PURPOSE AS PER NATIONALLY RECOGNIZED CODES, LOCAL Civ 1 L <br /> CODES AND GOVERNING AUTHORITIES. OF CA's-0 <br /> I <br /> 4. ALL MONITORING DEVICES SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. <br /> EXISTING ESO � � � v o o <br /> 5. PRIOR TO FUEL BEING PUMPED, STATION MUST HAVE VEEDER ROOT FUNCTIONAL AND MONITORING ANNULAR SPACES OF TANK c X <br /> AND DISPENSER SUMPS. N z :Ez <br /> v� 0 Q> Q& 00 <br /> 6. EVIDENCE OF FINANCIAL RESPONSIBILITY SHALL BE SUBMITTED TO GOVERNING AGENCY (BY COSTCO), IF REQUIRED. N <br /> Q <br /> 7• 2305.6 WARNING SIGNS. WARNING SIGNS SHALL BE CONSPICUOUSLY POSTED WITHIN SIGHT OF EACH DISPENSER IN THE m o � \ 00 <br /> FUEL-DISPENSING AREA AND SHALL STATE THE FOLLOWING: m <br /> 1. NO SMOKING. -0 0 rn o <br /> ® 2. SHUT OFF MOTOR. cv <br /> 3. DISCHARGE YOUR STATIC ELECTRICITY BEFORE FUELING BY TOUCHING A METAL SURFACE AWAY FROM THE NOZZLE. rn 3 c o V <br /> •N � N a <br /> 4. TO PREVENT STATIC CHARGE, DO NOT REENTER YOUR VEHICLE WHILE GASOLINE IS PUMPING. " a cn <br /> 5. IF A FIRE STARTS, DO NOT REMOVE NOZZLE-BACK AWAY IMMEDIATELY. <br /> 6. IT IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOLINE INTO UNAPPROVED CONTAINERS. w Q <br /> 7. NO FILLING OF PORTABLE CONTAINERS IN OR ON A MOTOR VEHICLE. PLACE CONTAINER ON GROUND BEFORE FILLING. z > <br /> Z w o <br /> 1 2 A B \ 8. 2305.5 FIRE EXTINGUISHERS. APPROVED PORTABLE FIRE EXTINGUISHERS COMPLYING WITH SECTION 906 WITH A MINIMUM RATING cn g N <br /> 3 5 2 2 OF 2-A: 20-B:C SHALL BE PROVIDED AND LOCATED SUCH THAT AN EXTINGUISHER IS NOT MORE THAN 75 FEET (23 860 MM) w -J <br /> FROM PUMPS, DISPENSERS OR STORAGE TANK FILL-PIPE OPENINGS. =Dx o z <br /> REMOVE EXISTING \ -w- Z i:� Z w N <br /> DISPENSER AND w N g z <br /> 9• INSTALLATION SHALL COMPLY WITH ALL APPLICABLE SECTIONS OF CHAPTER 23, 2013 CALIFORNIA FIRE CODE. > E <br /> REPLACE WITH NEW Q o N 00 � <br /> c� <br /> GILBARCO ENCORE 700S o 00 cv r- Z > o <br /> SERIES (TYP. OF 6) \ N Q 00 uj <br /> Z w <br /> Lo Ln CD Z o <br /> 3 <br /> —� LO LO j <br /> SHEET INDEX: ° YLn <br /> v C) N <br /> 1 OF 5 DISPENSER REPLACEMENT SITE PLAN <br /> UTILITY CONFLICT NOTE 2 OF 5 DISPENSER DETAILS sa�� <br /> CAU110N: 3 OF 5 VAPOR PRESSURE SENSOR KIT DETAILS .� <br /> THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE CAUTION! POTENTIAL UTILITY CONFLICT. CONTRACTOR SHALL 4 OF 5 ELECTRICAL SITE PLAN Q c� o <br /> T <br /> LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES FIELD VERIFY ALL EXISTING AND NEW UTILITIES PRIOR TO 5 OF 5 VEEDER-ROOT WIRELESS DETAILS = W <br /> 0 <br /> WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE CONSTRUCTION. SEE UTILITY CONFLICT NOTE �' o <br /> UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION A� <br /> PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY THE EXISTING WATER, STORM, AND SANITARY SEWER SERVICE SHOWN IS Jv <br /> LOCATE © (800) DIG-RITE AND THEN POTHOLING ALL OF THE APPROXIMATE, BASED ON FIELD SURVEYS AND AS-BUILT RECORDS. n �' > b N5 <br /> EXISTING UTILITIES I RITE ONS OF NEW UTILITY CROSSINGS TO THE GENERAL CONTRACTOR SHALL "POTHOLE" THE EXISTING UTILITIES ID, ; DRAWING DISCLAIMER NOTE Eel <br /> 0 CO <br /> TO VERIFY THE DIAMETER AND LOCATION (INCL. ELEVATIONS) PRIOR TO THIS SITE PLAN HAS BEEN PREPARED WITHOUT BENEFIT OF TITLE REPORT Q) <br /> PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS THIS <br /> ANY DISCREPANCIES IN THE LOCATION OF THE <br /> OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON SURVEY, OR LEGAL DESCRIPTION. BARGHAUSEN CONSULTING ENGINEERS DOES Ln <br /> UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. EXISTING PIPE OR INCOMPATIBILITY OF THE DESIGN SHALL BE a NOT WARRANT THE ACTUAL LOCATION OF PROPERTY LINES AND SETBACKS NOR g <br /> IF CONFLICTS SHOULD OCCUR THE CONTRACTOR SHALL CONSULT BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNERS REPRESENTATIVE, THE LOCATION OF EXISTING UNDERGROUND PIPING AND EQUIPMENT. IT IS THE � i <br /> BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL AND BARGHAUSEN CONSULTING ENGINEERS (425-251-6222). Call RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO VERIFY PROPERTY LINESE LO o <br /> DISPENSER REPLACEMENT SITE PLAN PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. SCALE 1= 10 W AND SETBACK DISTANCES WHERE THEY MAY AFFECT THE PLACEMENT OF NEW -0 0 V) CD <br /> 0 0 <br /> 0 5 10 2G WORKIN(iODAYS EQUIPMENT AS A PART OF THIS PROJECT. THE DRAWING REFLECTS EXISTING 0 r <br /> BEFORE YOU SITE CONDITIONS AS PROVIDED BY COSTCO FROM ARCHIVE RECORDS. <br /> DIG <br />