Laserfiche WebLink
Z GILBARCO DISPENSER WIRE COLOR REFERENCE GENERAL NOTES <br /> >'oti K m a�, 1 . BLACK #12: HOT TO A-2 (CD MODULE) & VARISTOR 1 . SEE MATERIALS LIST (T-2) FOR DESCRIPTION ON EQUIPMENT USED IN THIS <br /> �o�o N o 2. GREEN #12: TO A-10 (GROUND) 2. ROUTING C HTIONOWN ARE SCHEMATIC, FINAL LOCATIONS SHALL BE SHOWN ON AS-BUILT <br /> GRANT LINE RD 4. VAR3. ITE ES ES #12: NEUTRAL TO A-13#12: TO (UNLEADED #1(RDD);0(UNLEADED #2-RED/WHITE) DRAWINGS. 00 <br /> PROJECT LOCATION 5. BLUE #12: TO (PREMIUM) 3. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE CA BUILDING STANDARDS CODE, Q t <br /> 205 W 11TH ST T T ACY > 6. YELLOW #12: TO (DIESEL WHEN USED) MANUFACTURE'S INSTRUCTIONS AND OWNER'S GUIDELINES, WHICHEVER IS MORE STRINGENT. Q <br /> 7. YELLOW #14: SPARE 4. FUNCTIONS OF THE CONTINUOUS MONITORING: o Z Q r <br /> 0 8. PURPLE #14 SPARE NOTE: -MONITORING OF ALL ANNULAR SPACES. J J <br /> WORK 9. PINK #14: SPARE ALL WIRE TO BE THWN, -MONITORING OF ALL PRODUCT PIPING AND FILL SUMPS. W <br /> AREA OIL AND RESISTANT IL <br /> -PROVIDE .1 GPH PRESSURE LINE LEAK DETECTION (PLLD) OF w Z V <br /> Of 10. BROWN #14: SPARE NO EXCEPTIONS PRODUCT LINES. N J <br /> Lo <br /> o e 11. #14: TO B-9 (GRIND TWO WIRE OUT (-)) BLACK TWISTED PAIR -PROVIDE CONTINUOUS TANK LEVEL MONITORING. w <br /> >NON SHIELDED <br /> \� LL <br /> ��m 12. #14: TO B-19 (GRIND TWO WIRE IN (+)) WHITE -MONITORING OF ALL DISPENSER SUMPS. Z Q W <br /> NOT TO SCALE TWISTED PAIR THE CONTINUOUS MONITORING DEVICE SHALL PROVIDE POSITIVE SHUTDOWN OF TURBINES o J Q Z_ <br /> NOT TO SCALE 13. #14: TO A-9 (PUMP TWO WIRE OUT (-)) BLACK >NON SHIELDED AND DISPENSERS AUTOMATICALLY IN THE EVENT OF A LIQUID RELEASE AND MANUALLY Q U J <br /> 14. #14: TO A-19 (PUMP TWO WIRE IN (+)) RED THROUGH THE ESO SWITCH LOCATED ON THE CONTROLLER ENCLOSURE AND REMOTE ESO Q <br /> VICINITY MAP LOCATOR MAP DISPENSER WIRING NOTE: SWITCH AS INDICATED ON SITE PLAN. cn <br /> o U U) <br /> EXIT ROW OF DISPENSERS SHALL BE WIRED FOR TANK#1 & TANK#3 " ( ) Q Q <br /> ENTRANCE ROW OF DISPENSERS SHALL BE WIRED FOR TANK#2 & TANK#3 5. ALL CONDUCTORS SHALL BE CONTINUOUS (WITH NO SPLICES) STRANDED COPPER WITH CD L W W (� <br /> 75°C THWN INSULATION, OIL AND GAS RESISTANT. C/') Q J O <br /> 6. A SEAL OFF MUST BE INSTALLED PRIOR TO ENTERING AND LEAVING A o Y W 0 0 <br /> CLASSIFIED AREA. CONDUITS FIRST EMERGENCE FROM BELOW GRADE MUST BE <br /> N co <br /> CONNECTED TO A SEAL-OFF. Q m C* O <br /> 7. ALL CONDUITS SHALL HAVE INSULATED GROUNDING BUSHINGS INSTALLED AND TIED TOGETHER W/ #10 BARE U <br /> COPPER WIRE. BOND ALL INSULATED GROUNDING BUSHINGS AND GUTTER BOX BACK TO POWER CENTER GROUND. o 0 <br /> DO NOT PENETRATE INTRINSICALLY SAFE BARRIERS. o _ <br /> EXISTING TURBINE EXISTING TANK ANNULAR a z° ~ <br /> SUMP 8. ALL ELECTRICAL INSTALLATIONS SHALL COMPLY THE CURRENT 2013 CA ELECTRICAL CODE MINIMUM STANDARDS. <br /> (TYP. OF 3) (TYP. OF 4) <br /> EXISTING FILL SUMP 9. ALL EQUIPMENT SHALL BE U.L. APPROVED. <br /> (TYP. OF 3) KEYEDNOTES M-A <br /> 1 CONTRACTOR TO VERIFY DURING BID IF EXISTING WIRING CAN BE EXTENDED (RE-USED AND p <br /> NOT SPLICED) AND TO VERIFY THERE ARE EXISTING TWISTED PAIRS. OTHERWISE PROVIDE NEW 00 <br /> ° ° TANK <br /> ° WIRING TO EACH DISPENSER IN EXISTING CONDUIT: J z <br /> (92 OCTANE) 5#12 THWN; 4#14 THWN SPARE, (2)#14 TWISTED PAIR & 1 #12 GND. Q W Z <br /> ETHERNET CONDUIT INSTALLATION UNDER SEPARATE PERMIT : W O <br /> ) <br /> USE EXISTING ETHERNET CONDUIT FOR THE NEW ETHERNET CABLES. J <br /> PROVIDE, (3) BELDEN CABLE #7826A FROM DISPENSER TO THE EXISTING IDF CABINET, THEN O Z <br /> CONNECT (1 ) CABLE VIA THE NEW ETHERNET DISCONNECT FROM THE IDF AND BACK TO THE � w U <br /> EXISTING IDF PATCH PANEL. KEEP (2) AS SPARE COILED CABLE FOR FUTURE CONNECTION TO THE Q Q <br /> TANK #2 C=D EXISTING OR ADDITIONAL ETHERNET DISCONNECT IN THE IDF CABINET. Q J <br /> (87 OCTANE) REFER TO BLOCK DIAGRAM BELOW. <br /> ETHERNET DISCONNECT POWER: Q <br /> UTILIZE AND EXTEND THE EXISTING DISPENSER DATA DISCONNECT RECEPTACLE POWER O J <br /> EXISTING #4 CIRCUIT WITH 3/4"C, 2#12, 1 &12 GND TO NEW ETHERNET DISCONNECT. PLACE NEW 12CV, V 0 <br /> EXISTING ADDITIVE 20A RECEPTACLE AT THE TOP LEFT SIDE OF THE ETHERNET DISCONNECT. < <br /> ° TANK #1 ° TANK <br /> 1 ,500 4 DISPENSER SITE SPECIFIC WIRING: � <br /> (87 OCTANE) <br /> REMOVE EXISTING VEEDER ROOT CABLING AND USE WIRELESS UNIT. <br /> DISPENSER MONITORING (WIRELESS): lL <br /> EXISTING DOUBLE WALL NEW VAPOR EXISTING UDC SENSOR AND EXISTING BELDEN CABLE SHALL BE REMOVED. ADD NEW MAG <br /> FIBERGLASS (TYP ) PRESSURE SENSO� 7 16 0 SUMP SENSOR, VEEDER-ROOT WIRELESS TRANSMITTER AND BATTERY PACK IN EXISTING UDC. <br /> AT EXISTING VEN <br /> EXISTING CONTROLLER C B PROVIDE 120V POWER TO THE NEW RF CONSOLE IN THE WARMING HUT. UTILIZE EXISTING <br /> ENCLOSURE E-2 E-2JV 6 <br /> CHRIS M. TEBAL f <br /> A- 1 UPS CIRCUIT. <br /> • � C83 15 <br /> EXISTING VEEDER ,4 E WIRELESS TRANSMITTER, BATTERY AND PRESSURE SENSOR AT THE VENT STACK. <br /> ROOT ALARM _ <br /> MONITOR SYSTEM, <br /> MONITORED 24 O • T CIV 14 4�~ <br /> HOURS/DAY TLS-RF WIRELESS NOTE �' OF CA,\- <br /> 3 0 • EXISTING o INSTALLING CONTRACTOR SHALL FOLLOW THE VEEDER-ROOT <br /> 6 WIRELESS INSTALLATION MANUAL NUMBER 577013-964 REVISION F. w X <br /> EXISTING o 0 ~ `-' ~ <br /> EXISTING CANOPY • OVERFILL N 0 Q > Q N <br /> N Z � Z O <br /> OVERHEAD B 4 5 12 14 ALARM Q <br /> EXISTING ISLAND E_2 ADD WIRELESS UNITS) o m > 0 c° <br /> (TYP. OF 6) o 00 <br /> CD <br /> • --EXISTING c <br /> HEALY C.A.S N o ami a °' o <br /> U Q cn <br /> • <br /> cn a_ <br /> W <br /> O <br /> ::D <br /> Z W n <br /> cn g c o <br /> LJw X N <br /> Q Z W N <br /> 1 2 REMOVE EXISTING > rN N N g o E <br /> Not Installed oNr � > �_ <br /> DISPENSER AND cv 0 z Of <br /> REPLACE WITH NEW p � o <br /> O O O GILBARCO ENCORE 700S O N <br /> 0') 00 Z w <br /> SERIES (TYP. OF 6) <br /> 3;: LoLn � Z <br /> EXISTING ESO <br /> ❑ ❑ ❑ a0 W > :5 o <br /> U cn <br /> i <br /> cn <br /> AS BUILT <br /> Gj say <br /> !ONES COVEY GROUP,INC. 1212017 <br /> QQ) <br /> (3 QOn <br /> )® = z <br /> W o <br /> _� C) <br /> Jv� i <br /> DRAWING DISCLAIMER NOTE b8 0 °`'� <br /> U <br /> THIS SITE PLAN HAS BEEN PREPARED WITHOUT BENEFIT OF TITLE REPORT, E <br /> SURVEY, OR LEGAL DESCRIPTION. BARGHAUSEN CONSULTING ENGINEERS DOES <br /> Ln <br /> a NOT WARRANT THE ACTUAL LOCATION OF PROPERTY LINES AND SETBACKS NOR g <br /> THE LOCATION OF EXISTING UNDERGROUND PIPING AND EQUIPMENT. IT IS THE � 0 i <br /> Call RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO VERIFY PROPERTY LINES � o <br /> SCALE 1= 10' 811 AND SETBACK DISTANCES WHERE THEY MAY AFFECT THE PLACEMENT OF NEW Z r 0 0 <br /> ELECTRICAL S PLAN 0 5 10 20 TWO EQUIPMENT AS A PART OF THIS PROJECT. THE DRAWING REFLECTS EXISTING o i <br /> WORKING DAYS SITE CONDITIONS AS PROVIDED BY COSTCO FROM ARCHIVE RECORDS. T <br /> BEFORE YOU <br /> DIG <br />