Laserfiche WebLink
SEE NOTES t 2 <br /> TYPICAL TANK MONITOR OUTPUTS <br /> w 00 <br /> = oU <br /> W fn Z <br /> Rt Z 15 W <br /> STANDARD EM01 1NI`. Q Q (n Z T <br /> O <br /> o aJ <br /> L)C I Lo <br /> FUEL SHUTDOWN -- <br /> TANK MGNI rG W W Q <br /> PI PREPO <br /> PI PR LI PO PI PR LI PO� PI PR LI PO ® U W <br /> - _ X Q Z Z <br /> \J ® = J <br /> z m <br /> SWITCH (!J Q <br /> W <br /> U <br /> a Q ¢ a o o w w 0 W O <br /> _.— m Go DO o 3P/20A o 3P/20A AC1RCUI BREAKERS (p o <br /> POWER FROM 3P/20A o 3P/20A <br /> ADDITIONAL CIRC'U 1 BREAKER o BREAKER o BREAKER o BREAKER o NISTA tD IN (rD h <br /> STANDARD REMOTE MOUNTED 13R[F AKF RS SCD C0'� � � POWERBOX N N � N <br /> FUEL SHUTDOWN SWITCH 0-� i3Y G IERS <br /> REMOTE MOUNTED ADDITIONAL REMOTE 0 0 0 0 Y Y Y U <br /> FUEL SHUTDOWN LOCATED IN THE EM02 MOUNTED FUEL RESET ~ ~ ~ ~ ", <br /> SWITCH LOCATED IN EM01 . N/C MOMENTARY SWITCH LOCATED IN EM02 <br /> N/C MOMENTARY (IF USED) N/0 MOMENTARY <br /> d M N <br /> (IF USED) <br /> 1 <br /> MOUNTEDDITTIONAL EMOTEFUE / z <br /> SWITCH LOCATED IN EM01 . <br /> N/C MOMENTARY �r, <br /> / <br /> P 0 W R LG A QLD IN <br /> (,GIN r R 0 L <br /> PODULKBOX <br /> CON FACTORS S1 S2 S3 S4 UEI_INC CONTROLS <br /> SE=CYTON <br /> L`J <br /> FACTORY INSTALLED JUMPERS`�� <br /> REMOVE WHEN CONNECTING <br /> OPTIONAL SWITCH DEVICES. <br /> E E E E E <br /> TERMINAL STRIP LOCATED M M M M M !, <br /> IN DISPENSER/PUMP CONTROLS <br /> SECTION, <br /> L1 1_2 1_3 G L1 1_2 L3 G L1 1_2 1_3 G �Ll 1_2 L3 G <br /> ( '�> TYPICAL EMERGENCY STOP AND RESET BUTTONS MAY ALSO BE SUBIMERS BLE HOOK HOOK VARIABLE HOOK I HOOK �, <br /> LOCATED IN THE CASHIER CONTROL CENTER (CCO1 OR CCO2) PUMP <br /> N N N N SPEED W <br /> J <br /> ALL FIELD WIRING TERMINALS MUST BE WIRED WITH A MINIMUM CONTROLLERS <br /> CONTROLLERS CV <br /> 2 INSULATION RATING OF 60'C IF CIRCUIT IS RATED LESS THAN 100 Q W O <br /> AMPS OR A MINIMUM INSULATION RATING OF 75'C IF CIRCUIT IS <br /> RATED OVER 100 AMPS. FIELD WIRING IS INDICATED BY SOLID LINE. M1 M2 M3 G M1 M2 M3 G M1 M2 M3 G M1 M2 M3 G 0) <br /> I I J � 0) <br /> 0 <br /> = W � <br /> 3a = <br /> c Remote Shutdown And Reset Q <br /> E-6 NOT TO SCALE 0 0) O <br /> OAU) <br /> FROMU) <br /> WIRING TERMINALS TERMINAL STRIP U <br /> (BREAKOUT MODULE) �- <br /> H = Hot or 120V Line (In & Out) SUBMERSIBLE <br /> N = Neutral (In & Out) TURBINE M M M G M M M G M M M G M M M G <br /> HL = Hot for Lights 1 2 3 N 1 2 3 N 1 2 3 N 1 2 3 N <br /> 1 = Pump 1 or 1A Authorization - 'OiMPS D D D D <br /> 2 = Pump 2 or 2A Authorization 1� r PATENT 000 0 0 <br /> 3 = Pump 3 Authorization �` NE WORK BUS <br /> 4 Pump 4 Authorization n01, �- f o <br /> 87-1 87-2 92 SPARE <br /> CRT BREAKER <br /> G i INPUT - 20A <br /> DISP OUTPUT 120VAC MAX STAND ALONE STAND ALONE STAND ALONE STAND ALONE <br /> z CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION <br /> Z VARill AELF SPEED VARIABLE SPEED VARIABLE SPEED VARIABLE SPEED �W� 4 <br /> STP STP STP STP Q <br /> Wq <br /> 0 Pt 0 P2 0 P3 O P4 DIPOWER R W D 1 <br /> �������� ON TO BREAKER FOR DISPENSER #1 POWER �0 <br /> 21AUTH <br /> TYPICAL OF ALL DM-EX MODULES E5 �' <br /> n (20 AMP MAX - #12 AWG.)OFF m✓ <br /> o� SEE NOTE 5 <br /> DM-Exm m NETWORK BUS DISPENSER/PUMP CONTROLS <br /> INIMUM MODULE ® p . . . N $ z r z <br /> �1 z AwG 9u <br /> TERMINAL STRIP CONNECTION CHART <br /> 0 <br /> J <br /> - N NEUTRAL CONNECTION TO SUBMERSIBLE PUMP CONTROLLERS N N ' <br /> M <br /> D-Box171 <br /> r N YI ml <br /> TYPICAL MULTI-PRODUCT— t z a a G GROUND CONNECTION <br /> DISPENSER (MPD) o <br /> v d <br /> 5 PUMPS TO ADDITIONAL LP 120V LINE PRESSURE POWER (OFF DURING EMERGENCY STOP) <br /> RIBBON CABLE <br /> N z N z TYPICAL1-8 TYPICAL 1-8 DISPENSER MODULES o o $ o <br /> w F 1A PRODUCT #1 ; UMP AUTHORIZATION FROM DISPENSER <br /> N DISP #1 DISP #1 <br /> Z i - a <br /> DATA + 00 1B PRODUCT #1 PUMP CONTACTOR CONTROL POWER (IN POWERBOX PDC) <br /> PUMP SIDEGRIND SIDE 2A PRODUCT #2 PUMP AUTHORIZATION FROM DISPENSER <br /> DISPENSER #1 CARD ® to v <br /> READER TWISTED PAIR PER ( 2B PRODUCT #2 PUMP CONTACTOR CONTROL POWER ( N POWERBOX PDC) x c;v <br /> MANUFACTURER'S SPECIFICATIONS `TERMINAL LP MUST BE - <br /> COMMUNICATION JUMPED TO THE "B" N G L [Al1 z z 3 3 4 4 3A PRODUCT 3 PUMP AUTHORIZATION FROM DISPENSER 0 z DATA (DC) WIRING D 0 0 0 0 0 O SEE NOTE # ID1 5 IR <br /> TERMINAL FOR EACH STP) x a a <br /> 3B PRODUCT #3 PUMP CONTACTOR CONTROL POWER (IN POWERBOX PDC) w L< <br /> GENERAL NOTES ® ® 4A PRODUCT #4 PUMP AUTHORIZATION FROM DISPENSER (IF USED) wN N w 5z 8 <br /> 06 <br /> 4B PRODUCT #4 PUMP CONTACTOR CONTROL POWER (IN POWERBOX PDC) (IF USED) a00 (D m z o <br /> 1 ) Wiring is typical of all dispensers. A Ground Conductor (12 <br /> z rn I <br /> Awg) must also be run from each dispenser to the ground V V � N N <br /> bar of the Panel which powers the dispensers. Y 11 WL <br /> GENERAL NO z E <br /> TO DISPENSER/PUMP CONTROLS LOCATED z N N <br /> 2) See dispenser installation diagrams for termination labeling. IN POWERBOX PDC ENCLOSURE REFER TO TANK MONITOR MANUAL FOR ALL WIRING CONNECTIONS - Y d v N S <br /> AND OTHER SPECIFICATIONS REQUIRED BY MANUFACTURER, U <br /> 3) All field wiring terminals must be wired' with a minimum N o oNv ' <br /> THE TANK MONITOR IS TYPICALLY MOUNTED OUTSIDE THE POWERBOX sa w <br /> insulation rating of 90°C. O PDC ENCLOSURE ON AN ADJACENT WALL. Jy ay <br /> Q L Z o <br /> 4) Factory installed "Remote Off" jumpers on DM-EX Modules THE TERMINAL STRIP SHOWN IS FOR THE STANDARD DM-EX DESIGN. m N <br /> must remain in place during normal operation. Removal of THE STANDARD DM-EX DESIGN MAY BE CUSTOMIZED FOR ADDITIONAL = f1 �_ <br /> this jumper and wiring into a "Pan Sensor" System provides PUMP DEVICES, THERE BY ALTERING THE STANDARD DESIGN SHOWN. <br /> individual shutdown of each dispenser. PLEASE REFER TO ALL INFORMATION TO DETERMINE THE NUMBER OF QPOFEssjo ad' oNy°v <br /> DEVICES FOR EACH JOB LOCATION. �p� F 8 o c E <br /> 5) The wire size and number of conductors required forFGN2c v <br /> communication/data (DC) wiring must be determined by the �4ro/„oleo Z m o <br /> specifications of the dispenser manufacturer. Typically 2 Dispenser Wiring a Tank Monitoring System And Submersible Turbine Pump Wirpg <br /> conductors (Twisted Pair) are required when a card reader - - -- -- - >R a <br /> O O <br /> E-6 SCALE: NTS E-G SCALE: N F E <br /> s used In the Dispenser. - �T CML <br /> O <br /> $ r W a <br /> G <br /> Lt <br />