Laserfiche WebLink
�GHA CIVIL ENGINEERING,LAND PLANNING,SURVEYING,ENVIRONMENTAL SERVICES <br /> P ►�j�VF n [�pp�/] �I <br /> �� ( <br /> J. <br /> January 9, 2004 <br /> Facsimile: (209)468-3433 JAN 3 0 2004 <br /> S'A'G ENG�N� <br /> ENVIRONMENT HEALTH <br /> Michele Sterni Le PERMIT/SERVICES <br /> San Joaquin County <br /> Public Health Services <br /> Environmental Health Division <br /> 304 East Weber Avenue, 3rd Floor <br /> Stockton,CA 95202-2708 <br /> RE: Underground Storage Tank Plan Addendum <br /> Costco Wholesale Stockton Fueling Facility <br /> 1616 East Hammer Lane, Stockton, California <br /> Costco Loc. No. 38/Our Job No. 10199 <br /> Dear Michele: <br /> On behalf of Costco Wholesale (Costco), Barghausen Consulting Engineers Inc., is responding to clarify <br /> the questions that you have regarding the Plan Addendum submittal for the project referenced above. <br /> The Environ coaxial tee fittings shown on Detail D/T-6 shall have removable test plugs in the <br /> tees so that the secondary containment can drain into each of the respective dispenser sumps <br /> pursuant to your requirements (see the enclosed revised detail). <br /> "The cross connection between 87 octane tanks has been removed." This plan revision in the <br /> addendum does not affect the siphon piping, which is to remain as shown. The cross <br /> connection that was being referred to in the January 5, 2004 addendum submittal letter was <br /> the pressurized manifold piping, which used to be shown on the plans to run between the <br /> 87 octane turbines. This former pressurized manifold piping was normally closed with ball <br /> valves so that if there were a turbine failure, the ball valves could have been opened allowing <br /> one turbine to serve the entire site. This "87 octane cross connection piping" has been <br /> removed from the plans. <br /> I hope that this will clarify the questions that you have regarding the Plan Addendum Please notify me <br /> when the permits are ready to be issued, as well as of any outstanding permit issuance fees. If you have <br /> any questions or comments regarding the plans during your review, please contact me at (425) 251-6222. <br /> Thank you. <br /> ectfully, <br /> Stephen H. Kirk <br /> Project Engineer <br /> SHK/dm/ath [10199c.054.docl <br /> enc: As Noted <br /> cc: Kim Sanford;Costco Wholesale <br /> Jeanne Blissett,MulvannyG2 Architecture <br /> Jay S. Grubb, Barghausen Consulting Engineers, htc. <br /> F. Al Kendall,Barghausen Consulting Engineers,Inc. <br /> John Ellingsen,Barghausen Consulting Engineers,Inc. <br /> Harley Mattson,Barghausen Consulting Engineers,Inc. <br /> 18215 72ND AVENUE SOUTH KENT,WA 98032 (425)251-6222 (425)251-8782 FAX <br /> BRANCH OFFICES ♦ OLYMPIA,WA ♦ TEMECULA,CA ♦ WALNUT CREEK,CA <br /> w .barghausen.com <br />