Laserfiche WebLink
SEE CIVIL SHEET C-1 FOR REINFORCED CONCRETE SLAB LO <br /> ADJOINING CONDITIONS 18" CONCRETE CROWN (TYP.) SEE CIVIL DRAWING FOR SPECIFICATIONS. J <br /> ti Y W <br /> h 0 <br /> >ORSHOCRE <br /> PACTED SOIL l - xi COMPACTED SOIL - \ O <br /> 3'-0° EXTEND CONTINUOUS /\/vA/ OW EEXTEND CONTINUOUS MIN. ! MIN - - - FILTER FABRIC TO SLAB � / �/\//\//\// / � _ � Q W/FILTER FABRIC TO SLAB MIN. ,C - VVU VSLOPE EXCAVATANK V i VA o w m Z O J <br /> z EXCAVATION PER PROJECT SOILS REPORT, VA//VA \ � PEA GRAVEL -\ PEA GRAVEL /VA//VA/ VV/�A//VA�/ �n U (- O <br /> OSHA SOILS CLASSIFICATION AND TANK iA//A//A <br /> o MANUFACTURER INSTALLATION _f FOURTH LIET OF PEFl //\\\//\//\/�\ \ Q Q U Q <br /> / / / / GRAVEL, FILL TO TOP OF s -g // //\\//\\// /\ /\\// WALL OF o o. w w J W O O <br /> INSTRUCTIONS. ALL SHORING IF REQUIRED \//\//\//\//\ � ��� � /\/\/\/\ \/\ EXCAVATION v m a a <br /> a TO BE UNDERENGINESEPAARATE PERMITED AND PERMTBDY \/�\/�\ j\\/\\/�/\ 20,000FGALLON IBERG FIBERGLASS WALL ZO,000FGALLON IBERG FIBERGLASS WALL 20,000FGALLON IBERG AS DO ABLK WALL NN TANK \%\// //\\\/\\ \ INSTALL HLTER FABRIC g (r0 <br /> o CONTRACTOR. REFER TO ARTICLE 132008 \/\//�/�/�/N/�// UL 1316 LISTED AND UL 1316 LISTED AND UL 1316 LISTED AND \�\ \ AT TANK HOLE <br /> 0- OF PROJECT MANUAL \\//\\�\\\/\\�\\�\/ / / Y Y Y Y <br /> - - s s s s <br /> a \//\/ \// / //�//\/ \ _ METHANOL COMPATIBLE. METHANOL COMPATIBLE. METHANOL COMPATIBLE. d. a "dal a aT ¢u �P ) N N <br /> 10'-6" 0.D. - b 10'-6' O.D. c 10'-6' O.D. c ,c V <br /> mak' d �S <br /> / /\ / / / / ' � iC � al- �, u � dr _g^ THIRD LIFT OF PEA GRAVEL, � � � � �' C( <br /> � D � A�xs, U, i B C", a 2' <br /> I PEA GRAVEL BEDDING AND BACKFILL TYPICAL TO SUB \\�\\\j\\j\\�\\\/\\�\\\/\\ w 7 p O Ol C O C C TAMP GRAVEL BENEATH TANK 0 0 0 0 <br /> GRADE SURFACE (BOTTOM OF CONCRETE) /\/\/\ /\\ /x\ <br /> \\/\/\/\ ? _1r; A d d d C .. d . 1 <br /> / / - <br /> D LIFT OF PEA <br /> NOTE: \ \ \ \ \ \ ,_ Ak, , „ 0 TAMPGRAVEL BENEATH GRAVEL, <br /> ~ <br /> DEADMEN ARE TO BE PRE CAST ABOVE GROUND \\�\/\\/\/\/\/\//\ _ d a1 �,:: .- yo a i <br /> \/ \ \ \ \ \ \ \ \ 1 „- FIRST LIFT OF PEA GRAVEL <br /> AND LOWERED INTO EXCAVATION. \ � \ \ TAMP GRAVEL BENEATH TANK <br /> TAMPED GRAVEL BED <br /> �/xx A� �/��/j\�/��% I B CONC. DEADMEN 36"x12", TYP. OF (Z) <br /> EXTEND 12" GREATER THAN OVERALL <br /> T-3 INSTALL FILTER FABRIC <br /> NOTE: <br /> CONC. DEADMEN 18"x12" B I LENGTH OF TANK (TYP.) AT BOTTOM OF TANK HOLE <br /> FILTER FABRIC (DUPONT TYPAR OR MIRAFI 500X) IS (TYP. OF 2) T-3 (TYP.) <br /> REQUIRED FOR ALL INSTALLATIONS. FABRIC MAY BE I - 13'-0" - - 13'-6" - F- ----- - ---- 13'-0" - - -- - SIEVE ANALYSIS OF PEAGRAVEL IS REQUIRED. <br /> PINNED TO SIDE OF HOLE WITH WIRE, ETC. SEAMS <br /> MUST BE LAPPED 1 ' MINIMUM. IN WET HOLE NOTE: FOLLOW UST MANUFACTURER'S COMPLETE CURRENT INSTALLATION INSTRUCTIONS. NOTE: <br /> INSTALLATIONS FABRIC MUST EXTEND 1 ' ABOVE MAX. OSHA TYPE "C° SIMPLE SLOPE SHOWN IN THIS VIEW IF GROUNDWATER IS ENCOUNTERED DURING EXCAVATION FOR TANK <br /> HIGH WATER TABLE. INSTALLATION OR IF POTENTIAL EXISTS FOR SURFACE RUN-OFF INTO TANK <br /> PIT, CONTRACTOR SHALL STRAP THE TANKS TO THE DEADMEN AND BACK <br /> FILL TO TOP OF TANKS IMMEDIATELY AFTER TANK PLACEMENT, THEN <br /> A Typical Yank Burial CONTRACTOR SHALL ENTIRELY FILL TANKS WITH WATER. THE ABOVE, (TANK <br /> BALLAST & PLACEMENT BY FILLING WITH WATER) SHALL BE DONE IN ONE <br /> T-3 SCALE: 3/16"=1 '-0" CONTINUOUS PROCESS, TANKS SHALL BE PUMPED DRY ONLY AFTER FINAL <br /> BACK FILL AND CONCRETE COVER IS IN PLACE. <br /> W <br /> -� cV <br /> 3/4" GALV. JAW AND EYE TURNBUCKLE_ 48" CONTAINMENT COLLAR R-28 RESERVOIR W > 00 <br /> fl TURNBUCKLE LOCATIONS ON EACH TANK Fr <br /> 1 TO ALTERNATE BETWEEN SIDES OF TANK J 0 Q <br /> - 0 W <br /> 3aa <br /> 1 4"x3" STRAP WITH GUIDES 0 <br /> J <br /> / i 4"x3" STRAP WITH GUIDES BY <br /> / O <br /> ' BY TANK MFG. TO TANK AT � � '� TANK MFG. TO TANK AT ALL <br /> ALL DESIGNED LOCATIONS. DESIGNED LOCATIONS. O <br /> r - (A <br /> / _ <br /> R - <br /> SIDE OF EXCAVATION. � 48 CONTAINMENTCOLLA \ \ O <br /> �Y 1/2" GALVANIZED STEEL <br /> / I STRANDED CABLE. <br /> CO REBAR AT EACH ----,, <br /> CORNER w/ #3 TIES <br /> AT 16" O.C. HOLD \ L <br /> //\ REBAR L5" CLEAR OF 30" FLGD. MANWAY <br /> \�\%/\ FORMED SURFACES. - w/5 (4") NPT FIGS <br /> I L <br /> 18 x�2 <br /> w� 4 <br /> B Tank Hold Down Details Wim ' <br /> �o <br /> T-3 NqT TO SCALE 30" FLGD. MANWAY /jr 0 <br /> w/2 (4") NPT FTGS. }� p <br /> LD <br /> k 36- 1 /2" -� - <br /> BUOYANCY CALCULATION, 20,000 GAL. TANK .. <br /> CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br /> "CONTAINMENT SOLUTIONS" TANK WITH SPHERICAL ENDS, <br /> (10' NOMINAL) <br /> TANK LENGTH: 37' 5-1 /2" TANK DIAMETER 10'-6" g z <br /> ____r,) 7" CONCRETE SLAB AT TRY 38'-6" DEADMAN, EACH SIDE, 18" WIDE X 12" HIGH <br /> 87.6 LB/CF EMPTY TANK UPLIFT = 19,947 GAL \ J <br /> _ = 2667 CU FT <br /> 7.48 GAL/CF ° <br /> 41 ,5' / 2667 CU FT X 62.4 LBS/CF = 166,421 LBS (DISPLACED WATER) <br /> I TANK SUMP UPLIFT = (2) X 3. 14 X 2' X 4' = 100.5 CU FT O <br /> O U 6 O <br /> // i 100.5 CF X 62.4 LBS/CU FT = 6271 LBS (DISPLACED WATER) a <br /> TOTAL TANK UPLIFT = 166,421 LBS + 6,271 LBS = 172,692 LBS f <br /> o N <br /> 4' DIA. = CS <br /> SUMP HOLD DOWN CALCULATION � z � V <br /> - - -1- 3 -- - � TANK SLAB: .58' X 13.5' X 41 .5' = 325 CU FT 0 5 N <br /> O 2 4' MIN. BURY DEPT. 325 CU FT X 87.6 LBS/CU FT = 28,470 LBS a o <br /> 2Q CUBED BACKFILL ABOVE TANK: z z w <br /> TANK 4' X 10.5' X 37.5' = 1 ,575 CU FT - 100.5 CU FT = 1474.5 CU FT ¢ N N ro 50 0 <br /> 10.5' DIA. - ® 1 .5' GRAVEL COLUMN 474.5 CU FTX 57.6 LBS/ CU FT = 84.931 LBS ! Lo Z I <br /> i 9,900 Les CURVED BACKFILL ABOVE TANK: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N Q z w <br /> 6 3.14 X 5.25'ZX 37.5' = 3,245.5 CU FT - - ^ < <br /> 0.5' X 10.5' X 37.5' = 4134.4 CU f7 10" -!� ^^ w E <br /> r �r 1 16- 1 . TYP. N Z N N J > <br /> 1 ' X 1 5' X 38.5' f- - 1 -8 --- -- / ao w > > <br /> 5 4134.4 CU FT - 3,245.5 CU FT = 888.9 CU FT _ 00 Li V v > N <br /> DEADMAN 2 - 444.s cu F _ 5'-6 1 4" - - 6' - 10 1 2" -- - 5' -6" - 4'- 1 1 2" - - 8'-3" ,�--- 5' -6 1 /4" f <br /> 444.5 CU FT X 57.6 LBS/ CU FT = 25.603 LBS / / / d DN <br /> 0 GRAVEL COLUMN ABOVE DEADMEN: 1 <br /> 12 5' X 14.5' X 38.5' X 2_ = 1 ,675 CU FT - - -- - - - - 37'-5 1 /2' - -- - - - - y JC7 s� <br /> I 13'-6" 1 ,675 CU IFX 57.6 LBS/ CU FT = 96.480 LBS �QPOFESS/p Q o <br /> CONCRETE DEADMEN: NOTE: <br /> THE TANK FILL END SHALL BE INSTALLED NOTE: CONTRACTOR SHALL VERIFY EXACT <br /> V X 1 .5' X 38.5' = 57.75 CU FT c� <br /> ONE INCH LOWER IN ELEVATION THAN THE STRAP SPACING WITH TANK MANUFACTURERS b <br /> 57.75 CU FT X 87.6 LBS/ CU FT X (2) = 10,118 LBS ! w6 o�so z ❑, b. Nyo <br /> TOTAL HOLD DOWN: 255.502 LBS = 1 .48 SAFETY FACTOR TANK TURBINE END. �Exe 9-ao- ? M 8 o ca s <br /> I PRIOR TO HOLD DOWN CONSTRUCTION. j ,. <br /> TOTAL TANK UPLIFT: 172,692 LBS © DRY WEIGHT TO TANK: 9 900 LBS <br /> TOTAL HOLD DOWN: 255.502 LBS 1 Containment Solutions � CNt <br /> D <br /> Buoyancy Calculation 20,000 Gallon Tank 1 c 20K Tank Elevation ShowingStrapSpacing TES LIFTING LUG <br /> p g / INDICATES STRAP PLACEMENT LOCATION INDICATES HOLD DOWN STRAP CLIP <br /> ® <br /> T_3 NOT TO SCALE T-3 SCALE: 1 /2"=1 '-O" o p <br /> ,4 <br />