My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
INSTALL_2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 1:06:52 PM
Creation date
11/8/2018 10:22:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2004
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HAMMER\1630\PR0518624\2004 INSTALL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• California Edition:January 2002 <br /> Marley Pump Co. <br /> Red Jacket FX1, FX2; FX1V; FX2V Flexline <br /> (for Flexible Pipelines) <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification: Leak rate of 3.0 gph with Pr,= 100%and PFA=0%. <br /> Leak Threshold: 2.0 gph. A pipeline system should not be declared tight if the test result indicates a loss <br /> that equals or exceeds this threshold. <br /> Applicability: Gasoline,diesel, aviation fuel. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification: System tests pressurized flexible pipelines. <br /> Pipeline Capacity: Maximum of 49 gallons. <br /> Waiting Time: None between delivery and testing. <br /> None between dispensing and testing. <br /> Test Period: Response time is less than 3 minutes. <br /> System Features: Permanent installation on pipeline. <br /> Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Restricted flow to dispenser if leak is declared. <br /> Calibration: Equipment must be checked annually for capability of detecting a line leak of 3.0 <br /> gph and, if necessary,calibrated in accordance with manufacturer's instructions. <br /> Comments: Enviroflex pipeline with a bulk modulus`of 1,280 psi was used during this evaluation. <br /> To perform a valid test,time delays must be integrated into electronic dispensing <br /> equipment or retrofitted in junction box. Without this delay,there is no guarantee that a <br /> nozzle will be closed for sufficient time to allow leak detector to perform pipeline test and <br /> provide uninterrupted service. <br /> *See glossary. <br /> Marley Pump Co. Evaluator: Ken Wilcox Associates <br /> 500 East 59th St., P.O. Box 3888 Tel: (816)443-2494 <br /> Davenport, IA 52807 Date of Evaluation: 03/22/94 <br /> Tel: (888)262-7539 <br /> 136 <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of <br /> the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.