INSTALL_2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
INSTALL_2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 1:06:52 PM
Creation date
11/8/2018 10:22:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2004
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HAMMER\1630\PR0518624\2004 INSTALL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEFT_ WALL ELEVATION � REAR WALL ELEVATION RIGHT WALL ELEVATION n FRONT WALL ELEVATION <br /> E-2 SCiA' C' E-2 SCALE: 1 "=1 '-O" E-2 SCALE: 1 "= 1 '-0" � �SCALE 1 "- 1 '-O" <br /> E-2 <br /> 6" 5'-9" 1 '-6° <br /> 5'-9 a <br /> 25" 36 8" 6" 4" w z Q # <br /> 116" <br /> 40 ' 171) 311 <br /> a Q J Z O <br /> U <br /> LEFT WALL WINDOW o 02 z p <br /> ORIENTATION THIS SIDE GILBARCG r O o <br /> D-BOX o w ENCLOSURE / W W Q <br /> U POWERBOX DROP CEILING 1 ~ Q V" <br /> 95 z o DISTRIBUTION o W <br /> U-15 I I CENTER SEE NOTE #4 / / W J Q Z Z <br /> A-1 - --1 (PDC) 0- W = J <br /> SIDE GRIND <br /> ALLIED SEE NOTE #5 1 VEEDER R OT 1 ���/ o N w 5 OO O <br /> N _ _ ANDI I 96 / - Q W Y Q <br /> A-9 B-9 BOX CONDUIT LOCATION UNDER U-14 ALIGN HV/LS. PARTITION IN � \ o o w w W Q U (� <br /> A-19 + B-19 + ( I o m I— <br /> 1 N POWERBOX CENTER ® a A-1 WIREWAY WITH HV/I.S. DIVISION �4/ AIR Z W F- <br /> 94 p CONDITIONER 0) W <br /> CONTRACTOR DISCRETION. w (fl O <br /> I ON VEEDER ROOT MODULE m (n .- (A <br /> -� U- 15 1 ARRANGE TO MINIMIZE I 105 o tp <br /> 6' 7 6" O ) O 1 CAMERA POWER <br /> / 93 A-1 CROSSING OF CONDUCTORS I w 111 I / A-33,35 i s i s Y Z <br /> MEDIA FILTER GSM i <br /> / VFC VFC VFC BOX 109 J - a _� w 1 122 N U <br /> 10 I N CONDUIT ENCLOSURE UNDER 1 w 0 <br /> w o 92 104 U-14 LIGHT SWITCH N N N O U <br /> PHONE BOARD 6"x6"x36" 110 110 110 r CABINET BY G.C. I z 8-20 1 6"x6"x18" 6"x6"x42" A-1 6"x6"x18 PRE-WIRED <br /> WIREWAY W 6'x6'x36" 0 0 0 o FIBER o F REQUIRED w g7 HV o 0 31 o Z <br /> / A B C WIREWAY o 0 0 0 TERMINATION z N y o o WIREWAY WIREWAY WIREWAY LLLJJJ A- 12 a o N M g <br /> 11 DIVIDERSEl \ U-11 U-15 BOX 1 w cn I 106 98 I I.S. LV 1 �, o o IP m +� <br /> 0 U-15 64 63 62 13 15 17 23 1 N 24 1 5 34TT 5A-1 28 6 7 65 8 9 101112 14 16 22 Tsii- <br /> L 34 22 32 40 42 44 38 36 4/ I <br /> 66 62 65 57 25 26 29 31 33 <br /> ww 63 64 24 23 27 30 32 58 g <br /> SEALOFFI z w I 1 <br /> Z <br /> ' (TYP.) I w 103 U ZO) i 1 <br /> W I W Q V =I > FINISHED <br /> p I I _ \ <br /> O FLOOR 1 \ <br /> � <br /> Q g I I I <br /> I I I I <br /> LL <br /> GILBARCO DISPENSER WIRE <br /> 0 <br /> ! I <br /> CAMERA WIRING LAYOUT COLOR REFERENCE <br /> I I I I I I 1 1 1 1 I I I I <br /> z " <br /> LL CAMERA #1 - POINTS TO DISPENSERS 1 AND 2 <br /> CAMERA #2 - POINTS TO DISPENSERS 3 AND 4 1. BLACK #12: HOT TO A-2 (CD MODULE) & VARISTOR <br /> CAMERA #3 - POINTS TO DISPENSERS 5 AND 6 2. GREEN #12: TO A-10 (GROUND) <br /> CAMERA #4 - POINTS TO DISPENSERS 7 AND 8 I t I I I 3. WHITE 2: NEUTRAL TO A-13 (CD MODULE) & VARISTOR <br /> IF i i i i i i „ I CAMERA #5 - POINTS TO DISPENSERS 9 AND 10 <br /> I I I 4. RED 12: TO STPi MTRt <br /> I CAMERA #6 - POINTS TO DISPENSERS 11 AND 12 # / <br /> CAMERA 7 - POINTS 0 CONTROLLER ENCLOSURE I\ <br /> I # T 5. BLUE #12: TO STP2/MTR2 Cl <br /> CAMERA #8 - FONTS TO TANK FARM s. YELLOW #12: SPARE W 0 <br /> 1 1 1 1 1 1 I I <br /> - - - - - - - - - - - - - - - - -ITS - - � I- I- I ' <br /> - - - <br /> ' 7. YELLOW #14: SPARE J <br /> ® Q <br /> 8. LIGHT BLUE #14: SPARE ®_ ? <br /> 9 PIN W ` <br /> I - - - - - - - - - --- - - - <br /> - - - - - - - - - - _ _ - - - - - - - - - - - - - - - - - - - - -- - -- - - - - - - - - - - - ) j K #14: SPARE �[ <br /> - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - <br /> - - - - - - - - - - - - <br /> ( _ _ _ _ _ _ �' 1 I I� 10. BROWN #14: SPARE O Q <br /> it ( - -- - -- - - - --- - - -- — - - --- - <br /> -`" -- -- - - - - - ------ - - - -- - ` - -- - - - *1 11. #14: TO B-9 (GRIND TWO WIRE OUT (-)) BLACK h d <br /> - - - - - - - - - _ --� - - I 12. #14: TO B-19 (CRIND TWO WIRE IN (+)) WHITE > <br /> TWISTED PAIR o 0) U) <br /> y <br /> - 1 13. #14: TO A-9 (PUMP TWO WIRE OUT (-)) BLACK \ (� <br /> /> LD <br /> TWISTED PAIR <br /> I _ — <br /> 14. #14: TO A-19 (PUMP TWO WIRE IN (+)) WHITE <br /> II I <br /> I <br /> ENTRANCE EXIT AREA OVERFILO SHEET NOTES <br /> 1 1 <br /> ALARM AND ACKNOWLEDGE SWITCH <br /> (ALWAYS) & REMOTE EMERGENCY 1 . ROUTE CONDUIT TO EQUIPMENT AS INDICATED ON SHEET E- 1 . i <br /> \ '- - -- - - - - - - - - - - -- -- - - <br /> SHUT-OFF SWITCH IF REQUIRED I FILL EN 2. ROUTE CONDUIT TO EXTERIOR ENCLOSURE WALL AS INDICATED ILL <br /> 87 a4 i I 87 64 ' I 87 64 ' I � ' � �* <br /> ON SHEET E-1 . <br /> I \ JUNCTION BOX FOR O O I 10 O <br /> I I I 31 I 31 I 31 <br /> FUTURE EQUIP. (TYP. 3. GASOLINE CONTRACTOR TO TERMINATE CAMERA CONDUITS <br /> - --- ' <br /> _�� - moi '- � AT ALL EXIT SIDE - -- 121 i I I\ I i BELOW CANOPY DECK INTO ELECTRICAL BOX, LEAVING <br /> COLUMNS) - - - APPROXIMATELY 3' LENGTH OF WIRE/CABLE FOR FINAL O <br /> a 56 3 3 ENTRANCE 1 (TYP.) (1) 1 C W�_ ¢ <br /> 2 ss 35 EQUIPMENT HOOKUP BY GASOLINE CONTRACTOR. FIBER LENGTH <br /> 1g (4) BELDON #88760 <br /> SEE NOTE 9 19 (i) #12 GND TO BE 20' EXTRA @ EACH END. ( �Q <br /> 3/4" C (2) #10 3/4" C (2) #10 #3 (TYP.) o° N � r g° 4. FUNCTIONS OF THE CONTINUOUS MONITORING: �_j0 `J <br /> ^� J� ESD P ROOM �/ O +(1) #10 GND +(1 ) #10 GND 92 xoo v - -MONITORING OF ALL ANNULAR SPACES. � O ) <br /> (E.D.P. ROOM LOCATION POINTED A7 z J z w z w N -MONITORING OF ALL PRODUCT PIPING SUMPS. 0jl�o <br /> \\, <br /> SHOWN SCHEMATICALLY, TANKS a z °3 z °? a ° -PROVIDE .1 GPH PRESSURE LINE LEAK DETECTION (PLLD) OF W.- <br /> CONTRACTOR <br /> TO POINTED CL CONTROLLER ❑ 64 ❑ 64 ❑ ~ � (1) 3/4"BELD C PRODUCT LINES.DETERMINE ACTUAL ENCLOSURE (TYP.) 64 (3) BELDON 188760 -PROVIDE CONTINUOUS TANK LEVEL MONITORING. � <br /> LOCATION.) 87 87 87 (1) #12 GND -DISPENSER SUMP MONITORING, <br /> WAREHOUSE 39 37 37 , THE CONTINUOUS MONITORING DEVICE SHALL PROVIDE POSITIVE <br /> O4 O O7 2_ 11 SHUTDOWN OF TURBINES AND DISPENSERS AUTOMATICALLY IN <br /> THE EVENT OF A LIQUID RELEASE AND MANUALLY THROUGH m <br /> 51 51 51 VENT THE ESO SWITCH LOCATED ON THE KIOSK ENCLOSURE AND z <br /> TURBINE END STACK REMOTE ESO SWITCH AS INDICATED ON SITE PLAN. <br /> 5. ALL WIRES ENTERING CONTROL PANELS, MAIN PANELS, ° <br /> LEGEND <br /> AND SUB PANELS SHALL BE MARKED WITH PHASE TAPE y c�+I y til <br /> NOTE: CODING AS FOLLOWS: <br /> WAREHOUSE G.C. SHALL INSTALL A DEDICATED, POWER CONDUIT "A" PHASE = BLACK v x <br /> UNSWITCHED FOURPLEX OUTLET IN EDP ROOM AND C "B" PHASE = RED <br /> A DEDICATED, UNSWITCHED DUPLEX OUTLET BY P01NEft & DATA ONDUIT "C" PHASE = BLUE g $ <br /> BURGLAR PANEL IN EDP ROOM. FOR EXISTING CAMERA/COMM. CONDUIT CONTRACTOR TO LABEL TURBINES AND CONTROLLERS AS TO <br /> WAREHOUSE OR GAS FACILITY EXPANSION, BY GAS - INTRINSICALLY SAFE CONDUIT WHICH SIDE OF THE STATION THEY SERVE. GREEN CONTROLLER <br /> STATION G.G. CONDUIT RUN SCHEMATIC FROM KIOSK ENCLOSURE a INDICATES ITEM ON MATERIALS LIST SEE DWG. T-7 LIGHTS ARE TO GO OUT WHEN TURBINES ARE OFF OR LOSE <br /> POWER, v <br /> A -- - _ <br /> NTS # INDICATES DISPENSER NUMBERING AND POSITION 6. SEE DETAIL "J" ON DWG. T-5 AND DETAILS "A", "D" & "G" ON z <br /> DWG. T-4 FOR TANK MONITORING DEVICES. oN 3 N o <br /> - - - <br /> UJ x <br /> CONDUIT SCHEDULE Ll <br /> = w <br /> --- '-`-' N N N S Z o <br /> 00 <br /> CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT Q O [Nv <br /> PURPOSE FILL FILL PURPOSE FILL PURPOSE FILL PURPOSE FILL W Z - o <br /> # - SIZE. _ - # SIZE # SIZE # SIZE # SIZE Z rn 1 1 w w <br /> �< 01 2" PHONE SERVICE TO EDP ROOM 25 PAIR PHONE WIRE, (1) #12 GND 1® 1" DISPENSER POWER 5#12 THAN; 8#14 & 1#12 GND. ® 3/4" LOOP TO CAMERA PANEL (2) #12 THWN, (2) #12 GND * (NOT USED) © (NOT USED) r N N 5 c� <br /> < 0 2" SPARE TO EDP ROOM 25# PULL CORD a 1" DISPENSER POWER 5#12 THWN; 8#14 & 1#12 GND. � 1" LOOP TO RIGHT WALL RECEPTICAL (2) #12 THWN, (1) #12 GND ** � (NOT USED) • ® 3/4" LOOP FOR POWER TO MET'S � ��N w � I\ <br /> r < a) 1" EDP TO BURGLER PANEL ® ENTRY AREA (2) 18-2, (1) 18-6 • 1® (NOT USED) 7" LOOP TO RIGHT WALL E.S.O. AND V.R. (5) #12 THWN, (2) #72 GND ** (NOT USED) • ® 3/4" LOOP FOR POWER TO VFC'S 00 Y a;� � N o <br /> < CONTROLLER ENCLOSURE TO * ® ) / / (5) #12 THWN, (1) #12 GND ® 1" CAMERA @ CANOPY (LV) (3) RG59U COAXIAL, (3) #18-2 STRANDED • ® 3/4" LOOP FOR POWER TO VFC'S P <br /> 1" FIBER OPTIC - TO EDP BOO ,TWELVE STRAND (5MM K JACKET) 1 (NOT USED ¢ 3. 4" ESO VEEDER ROOT ALARM © ENCLOSURE <br /> (� 3 d" LOOP TO- 11 PHONE (2 PR) PHONE CABLE, (1) #12 GND ** ® (NOT USED) 1" VEEDER ROOT ALARM ® WAREHOUSE ENTRY/EXIT (3) #10 THWN, (1) #10 GND 1" CAMERA ® CANOPY (LV) (2) RG59U COAXIAL, (2) #I8-2 STRANDED • ® 3/4" LOOP FOR POWER TO VFC'S v0 e ONX S a <br /> • 6 1" UNLEADED TANK 1 TURBINE POWER (3) #10 THWN, 1 70 GND ** NKA ° � y 6S w <br /> Q # O # (NOT USED) 1" S. REM TANK #3 MONI GRIN DEVICES (5�Bc DE ABL #8 760�(T GND (9 1" CAMERA ® CANOPY (LV) (3) RG59U COAXIAL, (3) #18-2 STRANDED ® 3/4" FUTURE EQUIPMENT (4) #10 + (2) #10 GND <br /> • 07 3/4" UNLEADED TANK #1 TURBINE POWER (SPARE) 25# FULL CORD ® 1" LOOP TO VEEDER ROOT 25# PULL CORD ® 1" UNLEADED TANK #2 MONITORING DEVICES (5) BELDEN CABLE #88760 (1) #72 GND * (NOT USED) ® NOT USED <br /> • ® 1" UNLEADED TANK #2 TURBINE POWER (3) #10 THWN, (1) #10 GND ® 3" LOOP TO POWER CENTER AS NECESSARY 1" UNLEADED TANK #1 MONITORI . D . ICES (5) BL�UEN CABLE #88760 (1) #12 GND ** ® (NOT USED) ® NOT USED <br /> • 90 3/4" UNLEADED TANK #2 TURBINE POWER (SPARE) 25# PULL CORD 2" LOOP TO DISCONNECT (4) 3/0, (4) #4 GND 4 3/4" DISP NSER SENSOR & FUTURE ISD COMPONENTS (2) BELDEN CABLE #88760 (1) #12 GND * ® (NOT USED) QpOFE (�` <br /> • ® 1" SUPREME TANK #3 TURBINE POWER (3) #10 THAN. (1) #10 GND (a 3/4" FUTURE AIR/WATER REEL 25# PULL CORD + 3/4" DISPENSER SENSOR & FUTURE ISD COMPONENTS (3) BELDEN CABLE #88760 (1) #12 GND « (NOT USED) - _ 4 • PVC COATED RIGID METAL CONDUIT. 0.�Q�,F" / i V' ' F� V� 0 C❑�9 <br /> • 11 3/4" SUPREME TANK #3 TURBINE POWER (SPARE) 25# PULL CORD ® 3/4" FASCIA LIGHTS (3) #10 THWN, (1) #12 GND ® 3/4" DISPENSER SENSOR & FUTURE ISD COMPONENTS (2) BELDEN CABLE #86760 (1) #12 GND ® 3" CAMERA CABLES & SECURITY 70 WARHOUSE EDP (8) RG59U COAXIAL, (2) 18-2, (1) 18-6 * REQUIRED ONLY IN 4 ISLAND OR 3 ISLAND EXPANDABLE TO 4 ISLAND � ; - -''�2 m m <br /> CONFIGURATIONS. ydj �' co 0 BO <br /> © i" DISPENSER POWER 5#12 THWN; 8#14 & 1#12 GND. I� 1" CANOPY LIGHTS (6) #10 THWN, (1) #12 GND 3/4" DISPENSER SENSOR & FUTURE ISD COMPONENTS (2) BELDEN CABLE #88760 (1) #12 GND ® 3/4 LOOP TO PHONE PANEL - 2 #1 TH , (2) 2 NK ** REQUIRED ONLY IN 5 ISLAND OR 4 ISLAND EXPANDABLE TO 5 ISLAND � - 9-302 - A <br /> © 1" DISPENSER POWER 5#12 THWN; 8#14 & 1#12 GND. ® 1" LOOP FROM HV TO VFC WIREWAY 25# PULL CORD 3/4" DISPENSER SENSOR & FUTURE ISD COMPONENTS (2) BELDEN CABLE #88760 (1) #12 GND / ® i" FUTURE VENT STACK SENSOR 25# PULL CORD CONFIGURATIONS. 1 -✓ �, <br /> < NEW WAREHOUSE, WIRE PULL BY COSTCO I.S. GROUP, EXISTING WAREHOUSE ALL PULLS o <br /> ® 7" DISPENSER POWER 5#12 THWN; 8#74 & 1#12 CND. 3/4" ESO TO DISPENSERS (2) #12 THWN, (1) #12 GND ® 3/4" DISPENSER SENSOR & FUTURE ISD COMPONENTS (2) BELDEN CABLE #88760 (1) #12 GND ® (NOT USED) BY GAS STATION G.C. '� cm E � o <br /> + ADDITIONAL WIRING FOR IN-SYSTEM DIAGNOSTICS (ISD) PRESSURE SENSOR REQUIRED AT o 'O <br /> i <br /> ® 1" DISPENSER POWER 5#12 THWN; 8#14 & 1#12 CND. ® 3/4" ESO TO DISPENSERS (2) #12 THWN, (1) #12 GND * (NOT USED (NOT USED) DISPENSER CLOSEST TO TANKS. CONTRACTOR TO FIELD VERIFY LOCATION. r w W a <br /> o; <br />
The URL can be used to link to this page
Your browser does not support the video tag.