My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 1:02:11 PM
Creation date
11/8/2018 10:22:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HAMMER\1630\PR0518624\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Items#35 <br /> Probe Models <br /> Mae Plus Probes for Alternative Mag Plus Probes for Alternative <br /> Fluids with Water Detection Part NW Fluids without Water Detection Part No- <br /> Tank I.D. o.t OPH Leak 0.2 OPH Leak Inventory 0.7 OPH Leak 0.2 OPH Leak Inventory <br /> Detection Detection On Detection Detection Only <br /> 4' 846391-101 846391-201 846391-301 846391-401 846391-501 1 646391-601 <br /> 5' 846391-102 846391-202 846391-302 846391-402 846391-502 846391-602 <br /> 5'4" 846391-103 846391-203 646391-303 846391-403 846391-503 846391-603 <br /> 6' 846391-104 846391-204 846391-304 846391-404 846391-504 846391-604 <br /> 7' 846391-105 846391-205 846391-305 846391-405 846391-505 846391-605 <br /> 7'6" 846391-106 846391-206 846391-306 846391-406 846391-506 846391-606 <br /> 8' 846391-107 846391-207 846391-307 846391-407 846391-507 846391-607 <br /> 9' 846391-108 846391-208 846391-308 846391-408 846391-508 846391-608 <br /> 916" 846391-117 846391-217 846391-317 846391-417 846391-517 846391-617 <br /> 10' 846391-109 846391-209 846391-309 846391-409 846391-509 846391-609 <br /> _ 10'6" 846391-110 646391-210 846391-310 846391-410 846391-510 846391-610 <br /> 11' 846391-111 846391-211 846391-311 846391-411 846391-511 846391-611 <br /> 12 846391-112 846391-212 846391-312 846391-412 846391-512 846391-612 <br /> 2.OM 846391-113 846391-213 846391-313 846391-413 846391-513 846391-613 <br /> 2.510 846391-114 846391-214 846391-314 846391-414 846391-514 846391-614 <br /> 2.67M 846391-116 846391-216 846391-316 846391-416 846391-516 846391-616 <br /> 3.OM 846391-115 846391-215 846391-315 846391-415 846391-515 846391-615 <br /> Custom 846391-199 846391-299 846391-399 846391-499 846391-599 846391-699 <br /> Length <br /> k6'r.�wemed segs erey fiwn poh[a.,raterflxle Trot ieCwnmaMe]rw M1s'A4'ii05 wim'2r1m a a <br /> Floats Match Table <br /> 1111 Probe Functions Float Kit <br /> Inventory:Yes <br /> Mag Plus Probe for Alternative Fluids with Water Detection Leak Detection:Yes Gasoline Float Kit <br /> P/N 846391-1 xx or-2xx Water detection:Yes P/N 846400-xyo' <br /> Gasoline(<=20%Alcohol) Inventory Only Mag Plus Probe for Alternative Fluids with Inventory:Yes Case note for <br /> definitionxy <br /> Water Detection Leak below)Detection:No below)) <br /> P/N 846391-3xx Water detection:Yes <br /> Alcohol/Ethanol(<=100% Mag Plus Probe for Alternative Fluids without Water Inventory:Yes Alternative Fluids <br /> Alcohol,including E85) Detection Leak Detection:Yes Float Kit <br /> Methanol(<=100%Alcohol) PM 846391-4xx or-5xx Water Detection:No P/N 846400-xy4- <br /> ETBE(<=100%Ether) Mag Plus Probe for Alternative Fluids without Water <br /> MTBE(<=100%Ether) Detection 'Notes: <br /> Used Oil P/N 846391-13zz x=O->4"floats <br /> Inventory:Yes x=1->2"floats <br /> Fuel Oil#4 Leak Detection:No x-->3'floats <br /> Fuel Oil#4 Mag Plus Probe for Alternative Fluids without Water Detection:No <br /> Ethylene Glycol Water Detection y=o->5'cable <br /> Propylene Glycol P/N 846391-6xx y=1 ->10'cable <br /> Windshield Washer Fluid y=2->20'cable <br /> Leak Test Performance (Third Party Certified for all <br /> TLS-3xx Consoles') <br /> PROBE TEST TYPE PON PfFA-I TEST TIME <br /> 0.1 GPH Mag IF,[,e 0.1 GPH 99% 1% 3 Hours <br /> 0.1 GPH Mag Probe 0.2 GPH 99% <.1% 2 Hours <br /> 0.1 GPH Mag Probe w/CSLD 0.2 GPI 99% <.l% Continuous <br /> 0.2 GPH Mag 2 0.2 GPH 99% <.1% 2 Hours <br /> Ye la--Foorresa'ves the rantmtlwigepvdct soeGrtcedxnwnlwefeMaMe rolke.geese assure mef yeu es usig Me <br /> erect vavm dpmucr utdatua <br /> tfI VEEDER-ROOT O 2007 Veeder-Root Company • 125 Powder Forest Drive • Simsbury CI 06070 • USA <br /> 1111111111119:!�� Telephone:860-651-2700 • Fax:860-651-2719 • www.veeder.com <br /> VR 12960 P/N 577013-054 Rev.0 VR 6/07 <br />