EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
244
>
2300 - Underground Storage Tank Program
>
PR0231137
>
COMPLIANCE INFO 1987 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 1:16:56 PM
Creation date
11/8/2018 10:22:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987 - 2007
RECORD_ID
PR0231137
PE
2361
FACILITY_ID
FA0001554
FACILITY_NAME
MIRACLE MILE MARKET
STREET_NUMBER
244
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13708014
CURRENT_STATUS
01
SITE_LOCATION
244 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HARDING\244\PR0231137\COMPLIANCE INFO 1987 - 2007 .PDF
QuestysFileName
COMPLIANCE INFO 1987 - 2007
QuestysRecordDate
7/21/2016 3:39:19 PM
QuestysRecordID
3146929
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing 17/ <br /> Software Version Installed: <br /> Complete the foliowin checklist: <br /> Yes ❑ No* I Is the audible alarm operational? <br /> Yes ❑ No* Is the visual alarm o erationA? <br /> Yes ❑ No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with then proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> Pf N/A operational? <br /> 6f Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping4ena <br /> ary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yesensors initiate <br /> positive shut-down? (Check all that apply) ❑ Sump/Trench Sensors; ❑ Dispenser Cont Sensors. <br /> Did you confirm positive shutdown due to leaks and sensor failure/disconnection? ❑Yo.❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill device (i.e. noN/A mechanical overfill prevention valve is installed), is the overfill warning alarm visibledible at the tankfill in s)and o rutin ro rl If so,at what rcent of tank ca aci does the alarr? %Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or oipment replacedand list the manufacturer name and model for all relacement arts in Section E, below. <br /> Yes* No Was liquid found inside any secondary containment systems designed as dry systems? ( ll that apply)❑ <br /> Product; ❑ Water. If yes,describe causes in Section E,below. <br /> Yes ❑ No* Was monitorin s stem set-up reviewed to ensure proper settings?Attach setup reports,if applicable <br /> Yes ❑ No* Is all monitoring equipment oerational per manufacturer's s ecifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> A <br /> Page 2 of 3 03/01 <br />