My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1987 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
244
>
2300 - Underground Storage Tank Program
>
PR0231137
>
COMPLIANCE INFO 1987 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 1:16:56 PM
Creation date
11/8/2018 10:22:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987 - 2007
RECORD_ID
PR0231137
PE
2361
FACILITY_ID
FA0001554
FACILITY_NAME
MIRACLE MILE MARKET
STREET_NUMBER
244
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13708014
CURRENT_STATUS
01
SITE_LOCATION
244 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HARDING\244\PR0231137\COMPLIANCE INFO 1987 - 2007 .PDF
QuestysFileName
COMPLIANCE INFO 1987 - 2007
QuestysRecordDate
7/21/2016 3:39:19 PM
QuestysRecordID
3146929
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ytutN <br /> „ <br /> SAN JOAQUIN COUNTY ,,I <br /> t ENVIRONMENTAL HEALTH DEPARTMENT <br /> 304 East Weber Avenue, 3rd Floor, Stockton, CA 95202-2708 <br /> Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.sjgov.org/ehd <br /> <rFo'isN <br /> UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: In action Date: <br /> Pzzo MoTvAo <br /> Facilit a rens: UST# <br /> S44 WY IVl __ Product <br /> Facility Co tact: Title: Phones <br /> Mon-ori ]Panel- I Piping system: Overfill prevention: <br /> Pressurized 11 Suction ❑Gravit _ Mechanical [IAudible/visual <br /> Inspect- n type: iolations: <br /> outine Monitoring Certification ❑Installation ❑Other: ❑Ml-RDetect ❑M2-RPrev ❑M-3 Both <br /> # Code Section <br /> VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R V=Violation;RV=Re eat Violation V <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 & c Current Unified Program Consolidated Forms on file with EHD(Facility and tank forth) <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 c 2 D Monitoring&response plan is current and filed with the local agency <br /> 6 CCR 2712 i Monitoring&response plan is onsite <br /> 7 CCR 2712 6 Maintenance&monitoring records Ml <br /> 8 CCR 2643 d Daily monitoring of suction piping(pre-January, 1, 1984 <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present Ml <br /> 11 CCR 2630 d UST system monitoring equipment is properly located to detect a leak (Mi) <br /> 12 HSC 25291 UST system monitoring equipment isoperational M2 <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping&UDC is present Ml) <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 a) 2 Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak detector(s)are installed (MI) <br /> 18 CCR 2635 1 Spill container M2 <br /> 19 CCR 2635 2 Overfill prevention system (M2) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&20 containment <br /> 21 HSC 25291 (e) Water in 20 containment anal zed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases Ml <br /> 23 1 CCR 2715 Designated Operator: a Statement from UST owner, c-e Monthly inspection;(f)Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test Ml <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636(f)(4) Annual line tightness test Ml <br /> 28 CCR 2661 Repair for tank/piging has had tightness test M2 <br /> 29 CCR 2643 a Biennial tightness test of gravity piping( re-Jams 1, 1984 <br /> 30 CCR 2643 d Triennial line test for conventional suction piping(pre-Jamiary1, 1984) Ml <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 6 Permit to temporarily close UST system <br /> 35 HSC 25298 c) Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a Illegal abandonment of UST system <br /> 38 Other: <br /> E D INS ECPin gillOR: PHONE: UIC <br /> � Septic system: <br /> l ❑Serves>_20 people/day <br /> C V D Bt: 1 TITLE: 11 Receives other than sanitary waste <br /> ©w V1 PiL Other disposal methods: <br /> ❑Dry wells/French Drains <br /> EHD 23-02 <br /> 1/3/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.