My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1111
>
2300 - Underground Storage Tank Program
>
PR0506724
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:12:19 AM
Creation date
11/8/2018 10:22:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0506724
PE
2361
FACILITY_ID
FA0007594
FACILITY_NAME
WINE COUNTRY STATION/7-ELEVEN
STREET_NUMBER
1111
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04931056
CURRENT_STATUS
01
SITE_LOCATION
1111 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\K\KETTLEMAN\1111\PR0506724\COMPLIANCE INFO 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2008 - 2015
QuestysRecordDate
6/27/2018 4:14:35 PM
QuestysRecordID
3926585
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY 10 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.orci/ehd/unibii.html <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Fatality Wincountry e Count Station/7 Eleven Facty 1111 E. Kettleman Ln. Lodi, CA Datlon Oct 20, 2011 <br /> Name: Atltlress: Datte:ec <br /> VIOLATIONS <br /> # C7 C2 M Code Section HSC=CA Health and Safe Code;CFR=Code of Federal Regulations <br /> C1=Class i violation;C2=Class 2 violation'M=Minor violanon <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) IMT) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 1 1 10ther: ISee attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I CLASS 11,or MINOR-Notice to Comply) <br /> On site to witness that annual monitoring system certification testing and perform the routine inspection. <br /> 305. The 91 Bravo box float and chain in the number 5/6 and 7/8 sumps failed to stop the flow of product <br /> at the dispenser when tested. All monitoring equipment shall be maintained to activate an audible and <br /> visual alarm or stop the flow of product at the dispenser when it detects a leak. The service technician <br /> adjusted the chain and verified functionality. Corrected on site. <br /> 310. Approximately one quart of liquid was removed from the 91 turbine sump. If water could enter into <br /> the secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br /> Upon arrival the technician had already removed the liquid from the sump. The water line could be <br /> observed indicating how high the liquid had reached. Technician placed the liquid into the hazardous <br /> waste drum on site. Ensure that the turbine and dispenser sumps are maintained free of liquid. <br /> Corrected on site. <br /> 311. The 87 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable <br /> of detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, <br /> retested it, and it passed. Corrected on site. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by 11-20-11. <br /> I�ou x rrd*� C w��d `--ilk ;s doe. 4'lr <br /> ALL END STAFF TME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inepepan Recelvetl BY: V Title: <br /> EHD 23-02 Rev 09/01/11 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page