PROPERTY LINE 175.00' S88° OS' 30"W� <br />r <br />r .• r/rrr r r r••��• r •r•r�r �-•'-� r r rr�re -® o F�l o <br />r r <br />' EXISTING VENT RISERS TO - <br />REMAIN. REMOVE ANY <br />' RISERS NO LONGER IN USE <br />NEW 2"0 SINGLE-WALL <br />FIBERGLASS VENT LINE <br />(SLOPE 1/4" PER FOOT <br />MINIMUM UPWARD FROM <br />' TANK) <br />(2) NEW NDERGROUND DOUBLE-WALL / <br />�FIBERGLA S STORAGE TANKS 10' DIAMETER <br />& 8' RE INFORCED CONCRETE SLAB ) <br />(TANKS RNISHED BY THE DEALER <br />ED BY THE DEALER'S <br />3 GENERAL CONTRACTOR). ONE TANK <br />IS TO BE A 16,000 GALLON TANK <br />M DIVIDED INTO 10,000 GALLON REGULAR <br />UNLEADED & 6,000 GALLON PREMUM <br />UNLEADED. THE OTHER TANK IS TO BE// <br />41A 15,000 GALLON TANK DIVIDED INTO// <br />8,000 GALLON UNLEADED PLUS & // <br />b177,000 GALLON DIESEL FUEL <br />,000 <br />F <br />t <br />p / N <br />V) <br />O <br />P Q <br />In'ul <br />LLJ <br />:i <br />u /x <br />u <br />3"0 VAPOR 4� <br />RECOVERY <br />1 MANIFOLD R� <br />u� <br />I <br />'NEW 2"0 DOUBLE-WALL FIBER- <br />GLASS PRODUCT PIPING LINES <br />w/ 3"0 FIBERGLASS SECONDARY <br />u( <br />CONTAINMENT PIPE UP SOPE1J 4" <br />PER FOOT MINIMUM UPWARD <br />FROM TANKS) (TYPICAL) <br />M.W. <br />b <br />E'tiS�NG t0 R <br />\O <br />EXISTING EASEMENT & WATER SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT UNDERGROUND PIPING GENERAL NOTES <br />WELL EQUIPMENT TO REMAIN REQUIRED INSPECTIONS. <br />1. SHELL SERVICE STATION SPECIFICATIONS ARE TO BE FOLLOWED <br />FOR ALL WORK PERFORMED AT THIS SITE <br />ALL APPOINTMENTS FOR INSPECTIONS MUST BE MADE AT LEAST 48 HOURS IN ADVANCE 2. ALL WORK, INCLUDING PLUMBING AND ELECTRICAL, SHALL BE <br />FOR THE FOLLOWING: PERFORMED IN ACCORDANCE WITH LOCAL ADOPTED BUILDING <br />CODES AND SUPPLEMENTARY ORDINANCES, ALL AS DIRECTED BY <br />--' - - PRIMARY AND SECONDARY TANK(S) SHALL BE TESTED PNEUMATICALLY AT 3-5 P.S.I. COMPANY REPRESENTATIVE. <br />FOR ONE HOUR; ONE-HALF HOUR FOR PRIMARY TANK AND ONE-HALF HOUR FOR 3. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS AT <br />SECONDARY TANK. DOUBLE WALLED TANKS ARE EXEMPT IF ANNULAR SPACE IS THE SITE. NOTIFY COMPANY REPRESENTATIVE OF ANY DISCREPANCIES <br />EXISTING CATCH BASIN TO BE I <br />RETROFITTED TO INCLUDE NEW <br />1.STREAMGUARD" CATCH BASIN <br />OIL/SEDIMENT FILTER TYPE 11-0. <br />O (TYPICAL OF 4 CATCH BASINS) <br />- - _ (FURNISHED & INSTALLED BY THE <br />-- <br />----------- ----------- - - -- STATION DEALER'S CONTRACTORS) <br />-( <br />EXISTING UNDERGROUND II <br />WASTE OIL TANK & <br />CONCRETE SLAB TO REMAIN II ' <br />it <br />II � <br />11 <br />I O <br />P51 <br />,d 11 EXISTING CANOPY <br />GPq0N�p,�N I I TO REMAIN ' <br />ZO P II f <br />III I <br />E <br />GON MPtJ <br />Ey,S�O ZO V� <br />5 <br />EXISTING CANOPY - <br />COLUMN TO REMAIN <br />NEW DIESEL DISPENSER - <br />(FURNISHED BY THE DEALER <br />& INSTALLED BY THE DEALE <br />GENERAL CONTRACTOR <br />NEW GUARD POST (FURNISHED - <br />EXISTING CONCRETE DRIVE SLAB & INSTALLED BY THE DEALER'S <br />GENERAL CONTRACTOR) (TYPICAL <br />�p TO BE REMOVED .& REPLACED OF 20) <br />II ' <br />K'Cq w/ NEW 6" REINFORCED <br />F CONCRETE DRIVE SLAB -SLOPE II � <br />T ENTIRE SLAB TO DRAIN TO NEW <br />EXSTNG�ANGPY COLUMN TO II <br />2 �S REMAIN (TYPICAL OF 2) CATCH BASIN. II <br />NEW 2"0 SINGLE-WALL FIBERGLASS <br />/ �O OF,yry VAPOR RECOVERY PIPING (SLOPE II <br />1/4' PER FOOT MINIMUM UPWARD <br />4 FROM TAN D II <br />D I I <br />4 ° NEW 2"0 DOUBLE-WALL FIBERGLASS II <br />R - 4 PRODUCT PIPING LINES w/ 3"0 <br />-VR-O FIBERGLASS SECONDARY CONTAINMENT II <br />O Tp O PIPE (SLOPE 1/4" PER FOOT MINIMUM <br />+ II <br />4\ R+ UPWARD FROM TANKS) (TYPICAL) <br />]]]] e 4 O I% EXISTING 10" STORM DRAIN <br />�4 O I °\. a 8 I 4 II PIPE TO REMAIN <br />° N 3 x 2" REDUCERI- 0 <br />° P - FIIQING (TYPICAL) SEE.1 I1 <br />4.DE IL THIS PAGE <br />°4 e°I NEW 24" SQUARE CATCH BASIN II <br />4 w/ TRAFFIC RATED GRATE & <br />xI- \ .I SAND/GREASE TRAP PER CITY II <br />OF LODI STANDARD PLAN #205 <br />/ O..I4 a .' e (FURNISHED & INSTALLED BY I I <br />THE STATION DEALER'S II EXISTING STORM DRAIN- <br />- °_ _ ! - - - - _ _ 4 _ CONTRACTORS) MANHOLE TO REMAIN <br />1----J/_Yq_---1 <br />NEW 3"0 SINGLE -WALL - <br />FIBERGLASS VAPOR <br />RECOVERY PIPING (SLOPE <br />1/4" PER FOOT MINIMUM <br />UPWARD FROM TANK) <br />0 <br />_'_II-- - <br />I _ --------------- <br />_ _ - - - Z = = <br />R= <br />.O O O <br />I'. <br />° T <br />4 e <br />a.4 ° <br />(1 e <br />EXISTING L <br />TO REMAIN <br />B] <br />I <br />-----KEIT <br />EXISTING UNDERGROUND <br />SANITARY SEWER LINE <br />TO REMAIN <br />w <br />N <br />RELOCATED "DRESSER WAYNE" 3 -PRODUCT Q <br />GASOLINE DISPENSER w/ CARD READERS, <br />3 -HOSES EACH SIDE, & BALANCE SYSTEM r <br />(INSTALLED BY THE DEALER'S GENERAL <br />CONTRACTOR) (TYPICAL OF 4 DISPENSERS) I� <br />i' 30" E Q / <br />l <br />_ r r �� r r •�•r- - - �r�r�• <br />EMAN_ <br />71m�7 NOTE! ALL EXISTING ITEMS ARE TO REMAIN <br />0 5 10 15 UNLESS NOTED OTHERWISE. <br />GRAPHIC SCALE <br />+ UNLEADED PLUS <br />D DIESEL <br />I I NEW CONCRETE <br />a <br />© SHELL OIL COMPANY, ALL RIGHTS RESERVED 1995. <br />MONITORED USING EITHER PRESSURE OR VACUUM TESTING. (ALL EXTERNAL CONNECTIONS <br />BETWEEN SITE CONDITIONS AND INFORMATION SHOWN ON DRAWINGS, <br />SHALL BE SOAP TESTED WHILE UNDER PRESSURE). <br />PRIOR TO COMMENCING WORK. <br />PRESSURE PIPING SHALL BE HYDROSTATICALLY TESTED TO 1509 OR PNEUMATICALLY TESTED <br />4. <br />ALL BACKFILL OF UTILITY TRENCHES TO BE CLEAN WASHED SAND. <br />TO 1109 OF MAXIMUM ANTICIPATED SYSTEM PRESSURE BUT NOT LESS THAN 5 LBS. <br />5. <br />PIPING: A.O. SMITH RED THREAD 11 DOUBLE-WALL (PRODUCT). <br />PER SQUARE INCH AT THE HIGHEST POINT OF THE SYSTEM FOR A MINIMUM OF 20 MINUTES. <br />SINGLE-WALL (VENT/VAPOR). <br />ALL LINES OTHER THAN PRESSURE PIPING SHALL BE PRESSURE TESTED AT NOT LESS THAN <br />6. <br />CONTRACTOR SHALL PROVIDE A COMPLETE FUNCTIONING FUEL <br />3 P.S.I. AND NOT MORE THAN 5 P.S.I. FOR A MINIMUM OF 20 MINUTES AND SOAP TESTED <br />DISPENSING SYSTEM MEETING THE LETTER AND INTENT OF THESE <br />WHILE UNDER PRESSURE. <br />PLANS AND SPECIFICATIONS. <br />CONTAINMENT SUMPS SHALL PASS A 24 HOUR LEAK TEST. <br />7. <br />TANKS: 2-15,000 GALLON XERXES UNDERGROUND DOUBLE- <br />WALL FIBERGLASS TANKS (TANKS 10' DIAMETER) <br />OVERFILL PROTECTION SHALL BE CAPABLE OF DRAINING LIQUID BACK INTO FUEL TANKS. <br />8, <br />INSTALL B" REINFORCED CONCRETE SLAB OVER TANKS, SET MANHOLE <br />MONITORING SYSTEM SHALL PASS A FUNCTIONAL TEST. THE FUNCTIONAL TEST SHALL CONSIST <br />COVERS 1 1/2" ABOVE SLAB. GRADE TO DRAIN. <br />OF THE ACTNATION OF THE ALARM VIA THE MONITORING PROBES/SENSORS. <br />9, <br />ALL FITTINGS AND OPENINGS SHALL BE SECONDARILY CONTAINED <br />FINAL INSPECTION AND APPROVAL TO OPERATE WILL BE GRANTED AFTER THE ABOVE <br />PER TANK MANUFACTURERS SPECIFICATIONS. <br />REQUIREMENTS ARE SATISFIED AND A HARD COPY OF THE PRECISION TEST IS SUBMITTED <br />10. <br />ALL FILL BOXES TO BE 5 GALLONS MINIMUM & WATERTIGHT, <br />TO INSPECTOR AT SITE. <br />1" ABOVE SURFACE. (TYPICAL FOR PHASE i VAPOR RECOVERY) <br />THE CONTRACTOR'S APPROVED PRINTSET OF THE UST INSTALLATION SHALL BE KEPT AT THE JOB SITE AND <br />11. <br />ALL MANHOLE COVERS TO BE WATERTIGHT. <br />MUST BE SHOWN TO THE INSPECTOR UPON REQUEST. IN ADDITION, THE LOCAL FIRE DEPARTMENT SHALL <br />APPROVE UST INSTALLATION PRIOR TO COMMENCEMENT OF WORK. 12, <br />IF YOU NEED FURTHER ASSISTANCE, OR WISH TO SCHEDULE AN APPOINTMENT TO DISCUSS THE PLAN REVIEWI3. <br />INSTALL 4-3/4 H.P. SUB -PUMPS WITH A.P.I. DETECTORS, <br />INSTALL 4-2"0 DOUBLEWALL FIBERGLASS UNDERGROUND PRODUCT <br />OR FIELD INSPECTION, PLEASE CONTACT OUR UNDERGROUND STORAGE TANK STAFF AT (209) 463-3427. <br />LINES WITH PRESSURE MONITOR (FOR QUICK SHUT -DOWN), SEE <br />EQUIPMENT LIST & SPECIFICATIONS FOR COMPLETE EQUIPMENT <br />LISTING. ATTACH LIQUID PROBE LEAK MONITOR, WITH PIPING SUMP <br />TO TANKS. <br />I <br />14. <br />INSTALL 1-3"0 UNDERGROUND SINGLE-WALL FIBERGLASS VAPOR <br />RECOVERY LINE, MANIFOLD FROM MULTI -PRODUCT DISPENSERS <br />LJ <br />TO REGULAR UNLEADED TANK. <br />0 <br />15. <br />INSTALL 2-2"0 UNDERGROUND SINGLEWALL FIBERGLASS VENT <br />LINES (ONE FROM EACH TANK TO VENT RISERS.) <br />-_ <br />SLOPE 1/4" PER FOOT MINIMUM BACK TO TANKS. <br />16. <br />SLOPE ALL NEW PRODUCT/VAPOR RECOVERY PIPING 1/4" <br />PER FOOT MINIMUM BACK TO TANKS. <br />O <br />Z <br />17. <br />EXCAVATION FOR TANKS SHALL BE PER OSHA REQUIRMENTS. <br />18. <br />PROVIDE DEADMEN & STRAPS PER SHELL STANDARDS. <br />' <br />pC) <br />19. <br />PROVIDE TANK SHORING. (NOTE, 10' DIAMETER TANKS) <br />1 <br />M <br />20. <br />GENERAL CONTRACTOR SHALL FURNISH & INSTALL DEADMAN <br />HOLD DOWNS FOR ALL TANKS IN ACCORDANCE WITH DETAILS <br />r <br />!� <br />ON TANK DRAWINGS. IT IS CRITICAL THAT YOU MEET THE CROSS <br />SECTIONAL DESIGN & REINFORCEMENT REQUIREMENTS. IF YOU <br />W <br />W <br />ELECT TO USE PRE -FABRICATED CONCRETE DEADMAN HOLD DOWN <br />Z <br />UNITS, SHELL REQUIRES ENGINEERING CALCULATIONS TO CONFIRM <br />THAT SYSTEM IS EQUAL TO SHELL'S DESIGN. <br />J <br />W i <br />21. <br />ALL TESTING REQUIREMENTS (TANKS, LINES, BLOCKAGE TEST, <br />H <br />PRESSURE DECAL, CALIBRATION, ETC.) SHALL BE THE RESPONSIBILITY <br />cr. <br />OF THE GENERAL CONTRACTOR & INCLUDED IN BASE BID, NO <br />w <br />LL <br />f <br />F <br />EXCEPTIONS. <br />0 <br />( <br />22. <br />JTH-LINE PRESSURE MONITOR NOT REQUIRED <br />IL <br />CITY OF LODI <br />H� <br />FIRE DEPARTMENT NOTES <br />1. <br />ALL UNDERGROUND STORAGE TANKS TO COMPLY WITH SAN JOAQUIN <br />Z' <br />COUNTRY ENVIRONMENTAL HEALTH & CITY OF LODI. <br />2. <br />PERMITS TO INSTALL UNDERGROUND TANKS SHALL BE OBTAINED FROM <br />THE FIRE DEPARTMENT. <br />3. <br />EMERGENCY SHUT-OFF VALVE TO BE CLEARLY LABELED. <br />4. <br />NO SMOKING SIGNS TO BE CLEARLY VISIBLE. <br />•�� <br />5. <br />BUILDING PERMIT MAY BE ISSUED WITHOUT ANY FURTHER ACTION BY <br />r <br />THE FIRE DEPARTMENT. <br />I <br />6. <br />NO FIRES SHALL BE PERMITTED TO BURN ON THE CONSTRUCTION <br />SITE FOR ANY PURPOSE. THE USES OF DEVICES. OR TOOLS PRODUCING <br />A FLAME WHEN USED IN AN APPROVED MANNER AND NECESSARY FOR <br />THE CONSTRUCTION OF THE BUILDING WILL BE PERMITTED, <br />I LEGEND <br />7. <br />WHEN EXPOSED TO PROBABLE VEHICULAR DAMAGE DUE TO PROXIMITY <br />f NEW 2"0 DOUBLE-WALL FIBER <br />TO ALLEYS, DRIVEWAYS OR PARKING AREAS, ABOVEGROUND GAS <br />GLASS PRODUCT PIPING LINES <br />METERS, REGULATORS, AND PIPING SHALL BE SUITABLY PROTECTED. <br />w/ FIBERGLASS SECONDARY <br />CONTAINMENT <br />ANMENT PIPE (SLOPE 1/4" <br />8 <br />COMMERCIAL DUMPSTERS AND CONTAINERS WITH AN INDIVIDUAL <br />PER FOOT MINIMUM UPWARD <br />I <br />CAPACITY OF 1.5 CUBIC YARDS OR GREATER SHALL NOT BE STORED <br />FROM TANKS) <br />OR PLACED WITHIN 5 FEET OF COMBUSTIBLE WALLS, OPENINGS, OR <br />COMBUSTIBLE ROOM EAVES LINES UNLESS DUMPSTERS AND CONTAINERS <br />°_ <br />ARE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM. <br />NEW UNDERGROUND SINGLE- <br />ALL CONTAINERS IN WHICH COMBUSTIBLE TRASH, WASTEPAPER, OR <br />WALL FIBERGLASS VENT/VAPOR <br />RUBBISH IS KEPT OR STORED SHALL BE MADE OF METAL AND EQUIPPED <br />p / <br />LINES 2"0 OR 3"0 (SLOPE 1/4" <br />WITH ATIGHT-FITTING METAL LID WHEN LOCATED WITHIN A BUILDING OR <br />O// <br />PER 12' MINIMUM UPWARD FROM <br />ADJACENT TO A BUILDING. <br />TANK). PIPING TO BE 3" AFTER <br />MANIFOLD OF THE VAPOR <br />9. <br />APPROVED NUMBERS OR ADDRESSES SHALL BE PLACED IN SUCH A <br />RECOVERY LINES. <br />POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET <br />OR READ FRONTING THE PROPERTY. SAID NUMBERS SHALL CONTRAST <br />WITH THEIR BACKGROUND AND BE OF THE MINIMUM HEIGHT AS LISTED <br />VR VAPOR RETURN <br />IN THE FOLLOWING TABLE, <br />DISTANCE TO BUILDING ADDRESS SIZE HEIGHT <br />MEASURED FROM BACK OF WALK <br />R REGULAR UNLEADED <br />25 FEET 3 INCHES <br />26-40 FEET 5 INCHES <br />41-55 FEET 9 INCHES <br />P PREMIUM UNLEADED <br />I <br />OVER 55 FEET 12 INCHES <br />l <br />_ r r �� r r •�•r- - - �r�r�• <br />EMAN_ <br />71m�7 NOTE! ALL EXISTING ITEMS ARE TO REMAIN <br />0 5 10 15 UNLESS NOTED OTHERWISE. <br />GRAPHIC SCALE <br />+ UNLEADED PLUS <br />D DIESEL <br />I I NEW CONCRETE <br />a <br />© SHELL OIL COMPANY, ALL RIGHTS RESERVED 1995. <br />