Laserfiche WebLink
Jul 31 02 07: 12p K Curtis Construction 2 1t%-234-2411 p- 5 <br /> Nim"UNIUM VERIFICATION LABORATORY ANALYSIS <br /> oxVeGNAMS <br /> TANK TANK TPH-G TPH-D BTX&E CL HC TOTAL MTBE (MTBE. %=ALS PCB <br /> p CONTENTS 8015 8015 8020 8010 LEAD 8020 TBA.DIPE. ICAP/ETeE- AES 8270 <br /> _ 8260 8260 8260 8240 7420 8260 TAME) - or 8080 <br /> 8260 7421 8260 AA i <br /> LEADED GAS X X X X <br /> Z UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X X <br /> UNK FUEL X X X X X <br /> PROD. OIL X X X <br /> CHLOR. X <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTS X X <br /> LWASTED <br /> USED OIL X X X X X X X <br /> Ll SWEEMENNIN sassonnin I -- <br /> L All analysis methods are the designated EPA methods described in EPA SW 846,Third Edition. Those methods not found in SW <br /> 846 are specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix D(B),Table 3-5 on page A20 for <br /> minimum detection limits for motor vehicle fuel(gasoline and diesel). Refer to "Tri-Regional Board Staff Recommendations for <br /> Initial Evaluation and Investigation of UST's" for the waste and motor oil minimum detection limits. <br /> L Detection Limits that remain below the MCL,SILC or Allowable Limit or the contaminant in question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> L TPH-G Toul Petroleum Hydrocarbon.Gasoline,GC/FID(5030)8015 mod or GC/MS 8260 <br /> TPH-D Total Petroleum Hydrocarbon, Diesel.GC/FID(3550),8015 mod or GC/MS 8260 <br /> BTX&E Benzene,Toluene,Xylene&Ethyl Benzene,GCIPID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon.GC115D 8010.GC/MS 8240 or 526D <br /> TOTAL LEAD Total lead,AA 7420, AA 7421 or ICP-AES 601D <br /> L OXYGENATES MTBE, ETBE,TAME.DIPE,&TBA GC/MS 8260(For MTBE screen only you may use 8020) <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 601D or Atomic Absorption Spectrometry 7000. <br /> Metals:Cadmium,Chromium III and VI,Lead,Zinc and Nickel. <br /> PCB Polychlorinated Bipheoyls.GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography, Flame Ionization Detection <br /> L I Method 3050 Acid digestion <br /> Method 3540 Soxblet sample preparation <br /> L Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of bemew,bemene-free solvents are to be used. Fused capillary columns are preferred to packed <br /> L i columns:a packed column may be used as a"first cut"with 'dirty'samples or once the hydrocarbons have been characterized and proper <br /> QA/QC is followed. <br /> For drinking water sources. EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the <br /> detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy meal contamination may require further analysis. <br /> PHS-EHD recommends holding arose samples until disposal is indicated. <br /> LEH 23 046 (Revised 05/09/00) Page 8 <br />