My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1999 TANK TOP UPGRADE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
3011
>
2300 - Underground Storage Tank Program
>
PR0231883
>
INSTALL_1999 TANK TOP UPGRADE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:52 AM
Creation date
11/8/2018 10:24:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1999 TANK TOP UPGRADE
RECORD_ID
PR0231883
PE
2351
FACILITY_ID
FA0002111
FACILITY_NAME
BEN HOLT SHELL
STREET_NUMBER
3011
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
10018010
CURRENT_STATUS
02
SITE_LOCATION
3011 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\B\BENJAMIN HOLT\3011\PR0231883\TANK TOP UPGRADE 1999.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> UNION1 11 1 poll I <br /> 1 1/2" 0 SAFETY <br /> IMPACT VALVE <br /> 2" VAPOR FROM <br /> DISPENSER MANIFOLD ELECTRICAL CONDUIT TO EXTEND <br /> 112' PAST TOP LIP OF BOX <br /> DISPENSER <br /> SEAL JOINT BETWEEN ANCHOR <br /> BOX & DISPENSER WGORTEX <br /> JOINT SEALANT (TYP� <br /> SECONDARY CONTAINMENT SYSTEM <br /> It I:Typ� <br /> LOCATE AS DISP, <br /> MOUNTING BOLTS <br /> DISPENSER <br /> CONTAINMENT BOX <br /> FIBERGLASS <br /> VAPOR RECOVERY,,.; , " <br /> PIPING <br /> FIBERGLASS PIPE WITH <br /> SECONDARY CONTAINMENT <br /> ISLAND 18(w)"METRIC <br /> �o <br /> -- CONC ISLAND WITH DISP TERMINATE STAGE 11 LINE WHEN <br /> 6" MIN LAP <br /> STAGE !l VAPOR RECOVERY IS <br /> CONTAINMENT PAN ASPHALT PAVING <br /> NOT REQUIRED, MARTS STUB AT 6" REINF CONIC stAB <br /> DISPENSER GRADE W/ (BRASS OR CERAMIC <br /> JUNCTION l30X <br /> YARD GRADE MARKER. <br /> DISPENSER <br /> - B A <br /> ANCHOR PEAGRAVEL <br /> UNION B LTS " MCN <br /> 6" MIN � 2 DIA MIN <br /> REDDING L/t7PEAGRAVEL <br /> SHEAR VALVE--- DI PENSER <br /> FGLS PRODUCT OR VAPOR PIPING, FILTER FABRIC <br /> C NTAINMENT BOX SLOPE 1/$" PER FT' (MIN) DOWN — s" MIN <br /> DISPENSER ISLAND TO TANKS. USE MAXIMUM PITCH TANK SHOWN: 2" FGLS �/ 2'_e" MUTE: E <br /> EXPLOSION— LINES CONTAINED- FOR CLARITY, STAGE 11 VAPOR RECOVERY NOT SHOWN. <br /> • PROOF CROSS AVAIiABLE, NO P�-TRAPS ALLOWED, IN 4" HOPE PIPE HOWEVER, WHERE REQUIRED, DETAILS ARE 2"' &/OR 3" <br /> SINGLEWAI_L FGLS LINES AS ILLUSTRATED ON D-•-97004 <br /> •�• MINIMUM MINIMUM <br /> I WITH OPW60VS SHEAR VALVES AT EACH DISPENSER. <br /> DRIVE SLAB 8 UNDER CONCRETE UNDER ASPHALT <br /> POTTED RELAY LEVEL LINE _-�^` PIPE SIZE AREA (A) (B) SAID VALVES TO BE MOUNTED TO ISLAND CONCRETE <br /> ASSEMBLY <br /> � � USING SAME ANCHOR STRUCTURE AS PRODUCT SHEAR <br /> BOTTOM OF 2" UNCONTAINEO ISLANDS 12" 15" VALVES, TOPS OF VAPOR SHEAR VALVES MUST BE <br /> 3" UNCONTAINED ISLANDS 13" s" RIGIDLY ANCHORED TO DISPENSER STRUCTURE (NOT <br /> EXCAVATIONS 2"/4" CONTAINED ISLANDS 14" »" SHEETMETAL) OR VALVES WILL NOT OPERATE PROPERLY, <br /> ALT. YARD 18" 1 g, <br /> PRODUCT & VAPOR PIPING PEAGRAVEL SPECIFICATION IS THE SAME AS FOR FIBERGLASS <br /> — - - TANKS. THE MINIMUM 6" BEDDING MUST BE LAID & GRADED <br /> TO THE PROPER FALL BEFORE PIPE RUNS ARE INSTALLED. <br /> IF PEAGRAVEL IS NOT AVAILABLE, CLEAN MECHANICALLY COMPACTED SEE D•-97004, D-97013, <br /> SLOPE DOWN SAND MAY BE USED, SAND BACKFILL OVER PIPING SHOULD BE & 0 -97014 FOR MORE <br /> _... MECHANICALLY COMPACTED IN LAYERS OF 12" OR LESS TAKING DOUBLEWALL FIBERGLASS <br /> CARE NOT TOP TRAP PIPING 1N THE PROCESS. SAND MI��T' BE PIPING DETAILS, <br /> SEPARATED FROM PEAGRAVEL IN TANK AREA BY FILTER FABRIC. <br /> WHERE SAND BACKFILL IS USED UNDER ASPHALT IN YARD AREA, <br /> EYS FIBERGLASS BRIDGE TRENCH WITH 4" (MIN) UNREINFORCED CONCRETE PRIOR <br /> L.Ic�T1Y PRODUCT LINE FLEX BOOT, DO NOT USE f'ERNCO TO PAVING OVER WITH ASPHALT, CONCRETE MUST EXTEND AT <br /> CONNECTORS HEM: LEAST 8" BEYOND EDGES OF TRENCH. ASPHALT PAVING OVER <br /> Im_ SECONDARY Ic THIS CONCRETE BRIDGE MUST BE AT LEAST 1--1/2" THICK. <br /> CONTAINMENT 1Q WHERE NO METALLIC CONDUIT EXISTS IN PIPE TRENCH, OPTIONAL TO ADD <br /> FLEX CONNECTOR LINE 2" FRP STRAIGHT J 12 GA BARE COPPER WIRE TERMINATED IN TURBINE SUMPS AND DISPENSER <br /> FANS/SUMPS. BY PLAC}NG A SMALL D,C, CURRENT ON SAID WIRE, PIPING <br /> (MIN RADIUS 6") <br /> COUPLING, 45' ELL CAN BE TRACED WITH A METAL DETECTOR. <br /> T... _ OR 90' ELL. <br /> NOTI=„ SEAL ALL PRODUCT & VAPOR PIPING THRU DISPENSER These drawings and specifications are Shelf Oil Company's <br /> CONTAINMENT BOX WALL LIQUID AND VAPOR TIGHT �" STAINLE generic depictions of one or more components of its <br /> CLAMP TYP) standard retail service station designs. They are not <br /> ��� /\ A Ii"""`'� �P""'►•��1'"°'1� \Q�1 intended for use on specific projects. Thaw drawings and <br /> specifications are the confidential and proprietary property <br /> of Shell Oil Company and shall not be copied or reproduced <br /> Illwithout Shell's written authorization. <br /> h I' <br /> 2" FRP PIPE \ <br /> Shell Oil Company. All Rights Reserved 1997 <br /> REV IDATE1 I BY IAPPD <br /> SECONDARY CONTAINMENT L L a OIL PRODUCTS <br /> PIPE <br /> ti.. COMPANY <br /> �--- --- -�-� HOUSTON, TX <br /> F__ <br /> UNDERGROUND PRODUCT PIPING <br /> T DOUBLE WALL FIBERGLASS <br /> 3011 WEST BENJAMIN HOLT DRIVE <br /> CALIFORNIA STOCKTON, <br /> 2" FRP TEE SECONDARY CONTAINMENT 't TEE N <br /> SCALE: NONE" ENGR.: OR MARSHALL <br /> DATE: 4/l/1997 WIC#:E30Oa <br /> T/ TEE N R DWN, BY. GR MARSHALL <br /> GHKD, BY; DR- 97012 -- 00co <br /> i <br />