Laserfiche WebLink
I min <br /> UNDERGROUND PIPING GENERAL NOTES <br /> 1. SHELL SERVICE STATION SPECIFICATIONS ARE TO BE FOLLOWED <br /> FOR ALL WORK PERFORMED AT THIS SITE <br /> 0 5 10 15 2. ALL WORK, INCLUDING PLUMBING AND ELECTRICAL, SHALL BE <br /> PERFORMED IN ACCORDANCE WITH LOCAL ADOPTED BUILDING <br /> CODES AND SUPPLEMENTARY ORDINANCES, ALL AS DIRECTED BY <br /> GRAPHIC, SCALE COMPANY REPRESENTATIVE. <br /> 3. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS AT <br /> THE SITE, NOTIFY COMPANY REPRESENTATIVE OF ANY DISCREPANCIES <br /> BETWEEN SITE CONDITIONS AND INFORMATION SHOWN ON DRAWINGS, <br /> PRIOR TO COMMENCING WORK, <br /> 4. ALL BACKFILL OF UTILITY TRENCHES TO BE CLEAN WASHED SAND. <br /> S <br /> 5. PIPING: A,O. SMITH RED THREAD II DOUBLE—WALL (PRODUCT), <br /> 6s* 00" PROPERTY LINE 155.00' S75' 22' 34"E SINGLE---WALL (VENT/VAPOR). <br /> 15.01 ' '� " r waw ... ..,, ..■.� 'rte M �rr�■ """ .. w�wrwwe..ww "'"` "'"' ww�www w mm '"" " 'ur" . M � M .,r.r.w..ns " '� "� ir'r' � """ � 6. CONTRACTOR SHALL PROVIDE A COMPLETE FUNCTIONING FUEL <br /> 1© © 7 �� L � DISPENSING SYSTEM MEETING THE LETTER AND INTENT OF THESE <br /> PLANS AND SPECIFICATIONS. <br /> 1 7, TANKS: 2 EXISTING 15,000 GALLON XERXES UNDERGROUND DOUBLE-- <br /> j WALL FIBERGLASS TANKS TO REMAIN, <br /> I 1 8. INSTALL 8" REINFORCED CONCRETE SLAB OVER TANKS. SET MANHOLE <br /> COVERS 1 1/2- ABOVE SLAB. GRADE TO DRAIN. <br /> 9. ALL MANHOLE COVERS TO BE WATERTIGHT. <br /> 10. SLOPE ALL NEW PRODUCT/VAPOR RECOVERY PIPING 1/4" <br /> EXISTING VENT RISERS <br /> TO REMAIN PER FOOT MINIMUM BACK TO TANKS, <br /> r <br /> 10 <br /> 1f 06 11, ALL TESTING REQUIREMENTS SHALL BE THE RESPONSIBILITY <br /> OF THE GENERAL CONTRACTOR & INCLUDED IN BASE BID, NO <br /> EXISTING GAS METER 10 <br /> EXCEPTIONS. <br /> TO REMAIN <br /> - l <br /> f 1 LEGEND <br /> N NEW 2"0 FIBER GLASS PRODUCT <br /> •� PIPING LINES w/ YO FIBERGLASS <br /> SECONDARY CONTAINMENT PIPE <br /> W (SLOPE 1/4" PER FOOT MINIMUM <br /> �!I UPWARD FROM TANKS) <br /> NN <br /> Lo <br /> rTj 1 N f 1 -` 1 � --- --�•- -- NEW UNDERGROUND SINGLE— <br /> EXISTING LUBE BAY �.. WALL FIBERGLASS VENT/VAPOR <br /> LINES 2"0 OR 3"0 (SLOPE 1/4" <br /> N BUILDING TO REMAIN .1 PER 12" MINIMUM UPWARD FROM <br /> TANK), PIPING TO BE 3 AFTER <br /> OF THE VAPOR <br /> RECOVERY LINES, <br /> J <br /> cV f p r r VR VAPOR RETURN <br /> N Q I <br /> • —_ EXISTING WASTE OIL TANF, RH 87 REGULAR UNLEADED <br /> N ----�— <br /> N CONCRETE SLAB TO Rl:'r;iA,IN t <br /> I 92 PREMIUM UNLEADED <br /> Z <br /> r 1 EXISTING (2) 15,000 GALLON a <br /> F— ( „XERXES" UNNRGROUND DOUBLE 4 F4_ NEW CONCRETE <br /> F- NEW 2"0 SINGLE--WALL FIBERGLASS WALL FIBERGLASS STORAGE TANKS <br /> VAPOR RECOVERY PIPING (SLOPE (10' DIA.) TO REMAIN, EXISTING <br /> NEW 6"0 STEEL GUARD POST- CONCRETE SLAB TO BE REMOVED <br /> Q.. 1/4' PER FOOT MINIMUM UPWARD 8c REPLACED BY NEW 8" <br /> (� (TYPICAL OF 16) (BY EQUILON'a FROM TANK) (TYPICAL) NEW `L"0 FIBERGLASS PRODUCT <br /> (r GENERAL CONTRACTOR) PIPING LINE w/ 3"0 FIBERGLASS REINFORCED CONCRETE TANK SLAB. ° <br /> SECONDARY CONTAINMENT PIPE <br /> I I : .' .., _' .' t : ' 4• (SLOPE 1/4" PER FOOT MINIMUM f <br /> • r' UPWARD FROM TANK) (-TYPICAL) NEW REMOTE TANK FILL ° <br /> RELOCATED 'RASH HOOP , ..,':d <br /> (BY EQUILO 'S GENERAL d & TRUCK VAPOR RECOVERY <br /> CONTRACTOR (TYPICAL OF 4} a. ' <' -: `� (TYPICAL 2 PLACES) <br /> ` A. .M.D NOTES <br /> d � d <br /> ! ATED CANOPY (BY EQUILQ,N,'S �" v d 0 1 1. ALL NEW AND/OR EXISTING VAPOR RECOVERY PIPING LINES SHALL <br /> NERAL CONTRACTOR) r �'"� �!? BE 3" DIAMETER MINIMUM AT ANY POINTS IN WHICH THE LINES ARE <br /> I „ d (SELF SER E) � MANIFOLDED (OR SERVE MORE THAN ONE GASOLINE DISPENSER). <br /> NEW REINFORCED <br /> 1 ,r ,+., - ,:♦ T d • �. . Fm <br /> '. ... + q` .�.�.!-! rl NI=w 3"� VAPOR too <br /> CONCRETE SLAB / Q <br /> I _ <br /> RELOCATED CANOPY COLUMN 1, .+. „ * g2?', a M. ° a' c �� 4 RECOVERY MANIFOLD (TYPICAL 01= 2) 2, ALL NEW AND/OR EXISTING VAPOR RECCIVERY PIPING LINES ItiAAY <br /> & SHRQUTI BY F,QUILO,N S. d. L �. ,- _.. .. �; ... a. / <br /> CONTRACTOf 'I ° " �.,d, 4 a 0.? Q BEF2 DIAMETER MINIMUM AT ANY POINT IN WHICH THEY BRANCH <br /> GENERAL rg7 . ' '.+ 92 „ t~V OF T A SINGLE GASOLINE DISPENSER. <br /> (TYPICAL OF 4) '':ra 4" , '" •1 �t�N a <br /> a I �, a e e <br /> RELOCATED "DRESSER WAYNE" MULTI- d. • 'J k �' I � '4 4 _ c 4 3. EXISTING VENT RISERS MUST HAVE PRESSURE VACUUM VALVES. <br /> PRODUCT 'GASOLINE DISPENSER ` ; ' A " d"' �Q�' d THEY MUST BE INSTALLED IF NOT EXISTING PER THE A.Q.M,D <br /> r eY d� b <br /> •., .w/ CARD READERS,, BLENDERS, ,-d `• h �. v v <br /> SINGLE,HOSE EACH SI&E, & VAPOR an . 4 o <br /> "VAC :NOZZLES (SY 'EQUILON 5 ' . - . •' :.. <br /> GENERAL CONTRACTOR) 4., ,I�kEW:21;-6 C.L. 'OF DIS S, ', q q 4 44 .. <br /> .; - f <br /> (TYPICAL";OF. 4'DiSPENSERS) d''" : t . ;� :':� c <br /> I 87 <br /> - �,+ ; .' . , •• � ., , , I . .G ALS-$ �.�. ° Q a <br /> � .. RELOCATED AIR/WATER- � , . .,, ., A l�, d ...•.•r' 'yW <br /> REELS. (TYPICAL'2 PEACE�a) d .4: 4' i. • r.a a� w <br /> (BY,EQUILON'5 .GENERAL r, q'. .cr ' . e y d :� c:. '� d e <br /> J' C.ONTR, CTOR), . "e: . I ---� " f #�� q a 4 - 2" FIBERGLASS <br /> "° (ELIC!_ SERVE) <br /> VAPOR PIPING <br /> 3" FIBERGLASS TEE FROM DISPENSERS <br /> 'f. e n• d .�.'..r <br /> _VR '..�..', r. ,�,i .fr^ea .. '� O 4 .e 3" X 2" <br /> �. :.�.'L „ I:. 92� "• " FIBERGLASS <br /> [: d <br /> -'q a ... •,. A„ • -. .. ' . ., .. ° ', ".•,d`' •. ,,•, •-.. � � � �. 0£�A+IK�.,, a � BUSHINGS <br /> 4 9 ° • �. 4 <br /> �- N d, d. a ' a. NEy�f 'CONCFiE QF' KTO>v <br /> a n !4 i ° aa1TY <br /> L .02' d �, .,.•. A A a e a� <br /> 9 4 d - 4.. �.r.......�+ d •d. A 'QA a- <br /> j '•tl <br /> d A e PIPING TO TANKS <br /> q ° a ' 3" FIBERGLASS VAPOR <br /> '° e' d .d. `—..-:�_ .. ,.q a ,.b d' .� .tl - e ,d .• , `�° Qd � 2„/3” VAPOR PIPING <br /> ' �• ''d ' . d . � � • a '» ' � 75• ZZ 34 � � CONNECTION DETAIL <br /> � NO SCALE <br /> APPROVALS <br /> SMELL OIL COMPANY <br /> HOUSTON, TEXAS <br /> AREA ENGINEERING MANAGER DATE <br /> �� ,� DISTRICT MANAGER <br /> DATE Pro osed Pi in Plan <br /> � � �� A_� � �' C � I Ilf � „ �. ,� � � �' <br /> REVISIONS DISTRIBUTION MANAGER DATE <br /> NO. DATE BY COMMENTS CONSTRUCTION/DISTRICT ENGINEER DATE 3011 WEST BENJAMIN HOLT DRIVE & HIGHWAY #5 <br /> -�- PLANS PREPARED BY: STOCKTON, CALIFORNIA Po <br /> NOTE` ALL EXISTING ITEMS ARE TO REMAIN _ — --- A A $ E�ICINEERIi SCALE: 1 " 10>-0„ DRAWING # P--3K <br /> co <br /> UNLESS NOTED OTHERWISE. -` - PLANNING ENGINEERING CONSTRUCTION MANAGEMENT DATE: 7 14 99 <br /> 1243 ALPINE ROAD, SUITE 109 WIC # 204-7524--4404 <br /> WALNUT CREEK, CALIFORNIA 94-596 <br /> OWN. BY: RV � <br /> PHONE: 925--933--0578 FAX: 925-933-0588 GHKD BY: �w <br /> EQUILON ENTERPRISES LLC ALL RIGHTS RESERVED 1999. <br />