2300 - Underground Storage Tank Program
>
PR0231532
>
INSTALL_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2021 10:24:33 AM
Creation date
11/8/2018 10:24:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY GAS & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
01
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS3\C\CAMBRIDGE\16470\PR0231532\INSTALL 2018.PDF
QuestysFileName
INSTALL 2018
QuestysRecordDate
7/2/2018 8:57:03 PM
QuestysRecordID
3932889
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
has displaced the entire volume of the vent piping. The concentration of the tracer in the receiving container is then <br /> measured. <br /> Leak Simulation <br /> Injecting a tracer into the backfill performs a leak simulation. The leak simulation tracer is not one of the tracers used in <br /> testing the system. The migration period of the leak simulation tracer is monitored through the sampling probes. The <br /> minimum migration time required for the test is equal to the time required for the leak simulation tracer to move an <br /> acceptable distance. The minimal acceptable distance is the longest distance that the test tracer would have to travel from <br /> any leak location to the location of a sampling probe. <br /> Sample Collection <br /> Once the leak simulation migration period is determined, the inoculation and waiting period is completed and sampling <br /> can begin.Vapor samples are collected from all sampling probes. Additional vapor samples may be collected from sumps <br /> containing UST components, under dispenser containers (UDCs) and from the interstitial spaces of double walled <br /> components. <br /> Sample Analysis <br /> Samples are analyzed using an on site laboratory grade gas chromatograph (GC). The GC is calibrated using an external <br /> gas standard. Samples are analyzed by direct injection into the GC. The results are evaluated by comparison to the <br /> analytical standard. Whenever tracer is detected in the subsurface samples,blanks are run to validate the tracer detection. <br /> Spill-Bucket Testing <br /> Over-spill-buckets are tested hydro-statically. A decrease in water level indicates a leak. If leaks occur, spill bucket seals <br /> should be repaired or replaced. <br /> Reporting <br /> The findings of the Tracer Tighte ELD test and site evaluation will be summarized in a written report and sent to the client <br /> within two weeks of the completion of the fieldwork. All data acquired from probe and sump samples will be reported <br /> along with spill bucket hydro-test results. <br /> ' THIS INFORMATION IS THE PROPERTY OF PRAWR SERVICES,INC.. <br /> 3 of 3 <br />