My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 10:48:40 AM
Creation date
11/8/2018 10:24:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95336
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\COLONY\1442\PR0518458\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
6/15/2018 5:34:21 PM
QuestysRecordID
3916228
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer✓❑ Industry Standard ❑ professional Engineer <br />E] Other (Spec) <br />Test Method Used: E] Pressure ❑ Vacuum✓❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: See attached testing procedures <br />Equipment Resolution: Inches <br />Sump # 87 <br />Sump # 91 <br />Sump # <br />Sump # <br />Sump Diameter: <br />48" <br />48" <br />Sump Depth: <br />66" <br />70" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />13" <br />12" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />27„ <br />23" <br />Condition of sump prior to testing: <br />Fair <br />Fair <br />Portion of Sump Tested' <br />4" Above highest penetration <br />4" Above highest penetration <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />❑Yes ❑No QNA <br />❑Yes ❑No [Z]NA <br />[]Yes[] No [:]NA <br />❑ Yes ao SIA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />shutdown?` <br />❑Yes [-]No❑✓ NA [:]Yes[:]NoQNA E] Yes[] No E] NA E] Yes ❑No []NA <br />Was fail-safe verified to be <br />operational?* <br />❑Yes ❑No QNA <br />E] Yes [:]NoQNA <br />❑Yes [-]No[INA❑Yes <br />[-]No[]NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 minutes <br />15 minutes <br />Test Start Time: <br />10:41 am <br />11:40am <br />Initial Reading (Rj): <br />4.83966 Inches <br />3.58308 Inches <br />Inches <br />Inches <br />Test End Time: <br />10:56am <br />11:55am <br />Final Reading (RF): <br />4.83979 Inches <br />3.58249 Inches <br />Inches <br />Inches <br />Test Duration: <br />15 mins <br />15 mins <br />Change in Reading (RF -R,): <br />0.00013 <br />0.00059 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />Test Result: <br />El Pass ❑Fail <br />El Pass ❑Fail <br />❑Pass ❑Fail <br />El Pass ❑Fail <br />Was sensor removed for testing?✓❑Yes <br />❑No ❑NA <br />QYes ❑No ❑NA <br />❑ Yes ❑No ❑NA <br />❑ Yes ❑No [_]NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />OYes ❑No ❑ NA <br />Q Yes ❑ No []NA <br />[]Yes ❑No ❑NA <br />❑ Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />